Mémoire de Maîtrise
DOI
https://doi.org/10.11606/D.18.1997.tde-15072024-112350
Document
Auteur
Nom complet
Ana Carina Zanollo Biazotti Collares
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Carlos, 1997
Directeur
Jury
Vilar, Orencio Monje (Président)
Röhm, Sergio Antonio
Zuquette, Lázaro Valentim
Titre en portugais
A influência de características químicas do fluido de saturação no colapso dos solos
Mots-clés en portugais
colapso
constante dielétrica
defloculação
ensaios edométricos
fluidos de inundação
pH
Resumé en portugais
Muitos dos problemas de recalques nas áreas urbanas e industriais na Região Sudeste do Brasil estão associados ao colapso dos solos. Deformações induzidas por umedecimento (colapso) são determinadas por vazamentos oriundos das redes de esgoto e de abastecimento de água, ou ainda, vazamentos de sistema de armazenamento de combustíveis ou efluentes químicos. Neste trabalho analisa-se o colapso em solos tropicais considerando diferentes soluções como líquido inundante e mostra-se que a presença de um agente dispersivo na solução, tende a influenciar o potencial de colapso dos solos. Verifica-se ainda que a constante dielétrica influencia na magnitude do colapso observado sendo este tanto mais acentuado, quanto maior a constante dielétrica e que para as soluções estudadas o pH não interfere na grandeza dos colapsos medidos
Titre en anglais
The influence of characteristic chemistry of the saturation fluid on the soil collapse
Mots-clés en anglais
collapse
dielectric constant
dispersion
oedometer test
pH
saturation fluid
Resumé en anglais
Many settlement problems in urban and industrial areas in Southern Brazil are associated to soil collapse. Wetting induced strains (collapse) are govemed by water and sewer leakage as well as effluent leakage from industrial plants. In this paper the collapse behavior of tropical soils is analyzed considering different solutions and it is shown that the presence of a dispersive agent in the solution seems to influence the magnitude of soil collapse. It was also obsexved that collapse strains showed to increase with dielectric constant and that for the solutions studied, pH didn't interfere on the magnitude of measured collapse.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Collares_Ana_ME.pdf (4.55 Mbytes)
Date de Publication
2024-07-15
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.