• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Tesis Doctoral
DOI
https://doi.org/10.11606/T.18.2006.tde-23032007-143841
Documento
Autor
Nombre completo
Carlos José Marques da Costa Branco
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Carlos, 2006
Director
Tribunal
Cintra, Jose Carlos Angelo (Presidente)
Aoki, Nelson
Belincanta, Antonio
Carvalho, David de
Lobo, Ademar da Silva
Título en portugués
Provas de carga dinâmica em estacas escavadas de pequeno diâmetro com ponta modificada
Palabras clave en portugués
Colapsibilidade
Fundações
Ponta modificada
Resumen en portugués
Fundações por estacas escavadas com trado mecânico têm sido largamente empregadas para cargas de pequeno e médio porte. Como o processo executivo não consegue evitar a deterioração das propriedades do solo in situ no fundo da escavação, a única parcela confiável de resistência é aquela referente ao atrito lateral. No entanto, a ponta dessas estacas, muitas vezes, atinge estratos com resistência relativamente elevada e não consegue aproveitar as qualidades do estrato. O presente trabalho visou o estudo do comportamento desse tipo de estaca no perfil geotécnico típico da cidade de Londrina, através da execução de provas de carga dinâmica em 16 estacas de 0,25 m de diâmetro e 12 m de comprimento, sendo três estacas tradicionais e 13 estacas com ponta modificada. Foram feitas, também, provas de carga estática em duas estacas tradicionais, inspeção das pontas de todas as estacas e determinação dos parâmetros de resistência do solo. Os resultados mostraram que todas as modificações pesquisadas permitiram a utilização da carga estrutural nominal das estacas e que a mais eficiente foi a do tipo que promoveu a melhoria do solo na ponta com a adição de um estabilizante de solo.
Título en inglés
Dynamic load tests on small diameter auger piles with modified tip
Palabras clave en inglés
Colapsibility
Foundations
Modified tip
Resumen en inglés
Auger pile foundations have been widely employed for light to medium loads. As the executive process can’t avoid the degradation of the bottom excavation in situ soil properties, the only reliable resistance is a lateral friction parcel. However, these tip piles, many times, reaches relatively resistant strata and can’t take advantage from these strata qualities. The present paper seems study the performance of this kind of piles in typical geotechnical profile of Londrina, by dynamic load tests on 16 piles with diameter equal 0,25 m and length of 12 m, when three traditional piles and on thirteen kinds with tip modification. Were made, also, static load tests on three traditional piles, tip investigation on all piles and soil resistance parameters determination. The results shaw that all modifications researched was able to use the nominal structural load of piles and that the more efficient of them was the soil improvement by soil stabilizer addition.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
tese.pdf (7.24 Mbytes)
Fecha de Publicación
2007-03-26
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.