• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Mémoire de Maîtrise
DOI
https://doi.org/10.11606/D.18.2011.tde-25042012-111830
Document
Auteur
Nom complet
Mercedes Liliana Prieto Castillo
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Carlos, 2012
Directeur
Jury
Celestino, Tarcísio Barreto (Président)
Giongo, José Samuel
Kanji, Milton Assis
Titre en portugais
Ensaios de arrancamento e cisalhamento em descontinuidades simuladas reforçadas com barras de aço
Mots-clés en portugais
Ancoragens
Arrancamento em tubo duplo
Cisalhamento em juntas lisas reforçadas
Interface barra-graute
Reforço de maciço rochoso
Resumé en portugais
Ancoragens são muito utilizadas na estabilização do maciço rochoso pela rapidez e baixo custo, embora sua análise não seja completamente entendida devido à interação de diferentes materiais como rocha, graute e aço. Este documento apresenta os resultados de um estudo realizado em juntas lisas reforçadas com ancoragens. Foram ensaiadas ancoragens com barras de diferentes diâmetros e diferentes orientações em relação ao plano da descontinuidade. Os ensaios realizados para avaliar o comportamento deste tipo de reforço foram o ensaio de arrancamento em tubo duplo e o ensaio de cisalhamento em juntas lisas reforçadas. Os ensaios de arrancamento em tubo duplo demonstraram que a resistência ao arrancamento é dependente da resistência à tração da barra. As deformações internas no sistema foram idealizadas através da obtenção de um comprimento livre hipotético de uma barra livre submetida a tração. Nos ensaios de cisalhamento, avaliou-se a melhora da resistência ao cisalhamento de descontinuidades lisas reforçadas com barras ancoradas. Observaram-se dois picos de carga mobilizada antes da ruptura do sistema no caso de barras perpendiculares ao plano da descontinuidade. Este fato introduz significativa ductilidade ao sistema e é importante do ponto de vista de confiabilidade do sistema. A ruptura das ancoragens se produz devido a uma combinação de efeitos de tração, flexão, e cortantes. Os sistemas reforçados com áreas maiores de aço apresentaram maior ductilidade, e, portanto oferecem maior segurança. Os resultados sugerem que uma vez superado o comprimento mínimo ancorado a ruptura das ancoragens acontecerá por ruptura das barras de aço e não por aderência na interface barra-graute, concluindo-se que a resistência das ancoragens é dependente da resistência de ruptura e da área de aço utilizada. Finalmente, esta pesquisa contribui ao entendimento dos mecanismos de ruína que acontecem num maciço reforçado com ancoragens.
Titre en anglais
Pull-out and shear tests on discontinuities reinforced with steel bars
Mots-clés en anglais
Anchors
Double-pipe pull-out test
Rebar-grout interface
Rock mass reinforcement
Smooth-joint anchor-reinforced shear
Resumé en anglais
Rock anchors are widely used to stabilize rock masses due to their rapid installation and low cost. Their behavior is not fully understood because of the interaction of different elements such as rock, grout and steel. This document presents the results of both pull-out and shear tests on steel bar reinforced discontinuities. Tests were carried out with different diameters and orientations of bars with respect to the discontinuity plane. Double-pipe pullout tests and smooth-joint anchor-reinforced shear tests were performed. The results of double-pipe pull-out tests were analyzed in terms of both strength and deformations. Internal strains were idealized through a model based on hypothetical length of a free bar. In the smooth-joint anchor-reinforced shear tests, both increase in shear strength and ductility were evaluated. Two load peaks were observed in test with bars perpendicular to the joint plane. Ductility is significantly increased with respect to joints reinforced with inclined bars. This is important for reliability evaluation. The failure of anchors is produced by a combination of tensile, bending, and shear internal forces. The systems reinforced with a greater amount of steel presented more ductile behavior than those less reinforced. The results suggest that since the minimum anchor length is exceeded, the system failure is governed by the rebar failure and not by the adhesion in the rebar-grout interface. From this, it is concluded that the anchor strength is dependent on the strength and cross section area of the rebar. Finally, this research contributes to better understanding of the failure mechanisms of anchor-reinforced rock masses.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Date de Publication
2012-05-03
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.