  Bookmark and Share
 
 
Master's Dissertation
DOI
https://doi.org/10.11606/D.18.2017.tde-09052017-152424
Document
Author
Full name
Vivian Gomes Deolindo Bordin
Institute/School/College
Knowledge Area
Date of Defense
Published
São Carlos, 2003
Supervisor
Committee
Gonzaga, Adilson (President)
Coutinho, Kaline Rabelo
Slaets, Annie France Frere
Title in Portuguese
Modelo computacional da córnea e do humor aquoso
Keywords in Portuguese
Córnea
DICE
Espessura da córnea
Humor aquoso
Interação de energia
Olho
PO
Pressão intra-ocular
Abstract in Portuguese
A pressão intra-ocular (PO) é um importante parâmetro na avaliação da saúde ocular, sendo que o diagnóstico e a monitorização do glaucoma dependem de sua adequada mensuração. Entretanto estudos recentes mostram uma redução na PO medida através de tonômetros de aplanação após a cirurgia, o que provavelmente, é provocado por alterações da forma, estrutura e espessura da córnea em decorrência de procedimento cirúrgico freqüente no tratamento da miopia. A medida da PO é realizada aplicando uma pressão externa sobre o centro da córnea até que essa esteja totalmente plana. A deformação provocada pela pressão externa depende não somente da pressão intra-ocular mas também da energia de interação entre as moléculas da córnea, entre as moléculas do humor aquoso assim como, da interação mútua entre as moléculas do humor aquoso e da córnea. A quantidade e o tamanho das moléculas que formam estas estruturas (humor aquoso e córnea) também influenciam a deformação. Portanto, propomos neste trabalho, um modelo computacional que permite representar as moléculas da córnea e do humor aquoso com suas devidas espessuras e arranjos em função das energias de interação. O trabalho foi desenvolvido utilizando o programa DICE, o qual tem a finalidade de simular sistemas moleculares densos, compostos por diferentes tipos de partículas interagindo através de uma função (U) que descreve como a energia potencial de interação varia com a distância entre elas. Após diversas modificações dos parâmetros iniciais verificamos a tendência para o equilíbrio do sistema provando que o modelo é viável e factível de ser aplicado a avaliação da PO.
Title in English
not available
Keywords in English
not available
Abstract in English
Intraocular pressure is an important parameter in the evaluation of eye health so that the diagnosing and monitoring of glaucoma depend on their correct measuring. However recent studies show a reduction in intraocular pressure measured by means of plaining tonometers after surgery, what is probably caused by alterations in the form, structure and thickness of the cornea as a result of the surgical procedure frequent in treatment of miopy. Intraoculoar pressure is measured by applying an external pressure on the center of the cornea until it is completely plain (flat). The deformation caused by external pressure depends not only on intraocular pressure but also on the interaction force among the molecules of the cornea, among the molecules of the aqueous humour and also on the mutual interaction among the molecules of the aqueous humour and those of the cornea. The quantity and size of the molecules that make up these structures (aqueous humour and cornea) have an influence on the deformation as well. So, we propose in this work a computational model that allows to represent the molecules of the cornea and aqueous humour with their respective thickness and arrangements in relation to the interaction forces. The work has been developed with the program DICE, whose objective is to simulate dense molecular systems, composed by different types of particles interacting by means of a function (U) that describes how the potential interaction force varies according to thedistance between them. After various modifications of the initial parameters we verified the tendency to the balance of the system, proving that the model is viable and feasible of being applied in evaluation of intraocular pressure.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
Publishing Date
2017-05-09
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.