Disertación de Maestría
DOI
https://doi.org/10.11606/D.18.2018.tde-22012018-105745
Documento
Autor
Nombre completo
Lara Helena Elerbrock dos Santos
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Carlos, 1997
Director
Tribunal
Schiabel, Homero (Presidente)
Bellucci, Ângela Delete
Sanches, Rosemary
Título en portugués
Novo dispositivo com sensoriamento eletrônico para localização do raio central do feixe de raios-X em equipamentos de radiodiagnóstico
Palabras clave en portugués
Controle de qualidade
Ponto focal
Radiologia diagnóstica
Resumen en portugués
Neste trabalho, propomos um novo dispositivo para sensoriamento do campo ele radiação e localização do raio central do feixe de raios-X. Este dispositivo possibilita um alinhamento preciso entre os objetos de teste, utilizados pelos métodos de avaliação do ponto focal, e este raio de referência. Isto é feito através de um procedimento simples e seguro, utilizando sensores eletrônicos, sem expor o operador aos riscos da radiação, como na maioria dos dispositivos já existentes. Também apresenta um custo acessível e grande versatilidade, podendo ser utilizado em qualquer tipo de equipamento radiográfico. A necessidade do correto alinhamento destes objetos de teste eleve-se à grande variação verificada nas características do ponto focal ao longo do campo de radiação. Esta variação, denominada característica de campo, origina-se devido à inclinação do anodo do tubo de raios-X. A importância da avaliação do ponto focal deve-se ao fato de que este é o principal fator limitante da capacidade de resolução espacial em muitos sistemas radiográficos.
Título en inglés
not available
Palabras clave en inglés
not available
Resumen en inglés
In this work, we propose a new experimental device to determine the central ray position of the radiation beam. This device makes possible a precise alignmente between the test objects, used by the focal spot avaliation methods, and this reference ray. This is made through a simple and safety procedure, using eletronic sensors, without the risk of operator exposition to the X-rays. In addition, it presents a low cost and can be used in any type of radiographic equipment. The need for the correct alignment of the test objects is due to the Iarge variation of the focal spot characteristics along the radiation field. This variation, named field characteristic, is originated by the target angulation of the X-ray tube. The focal spot avaliation is very important due to the fact that it is the principal limiting factor of spacial resolution capacity of many radiographic systems.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2018-01-22
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.