Nom complet
Adilson Roberto Takeuti
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Carlos, 1999
Directeur
Jury
Hanai, Joao Bento de (Président)
Giongo, Jose Samuel
Stucchi, Fernando Reboucas
Titre en portugais
Reforço de pilares de concreto armado por meio de encamisamento com concreto de alto desempenho.
Mots-clés en portugais
concreto de alto desempenho
encamisamento
fibras de aço
pilares
reforço
Resumé en portugais
Este estudo apresenta os resultados de uma investigação experimental constituída de três séries de ensaio, cada uma envolvendo dois modelos: um pilar básico de concreto armado, representando o pilar a ser reforçado e um pilar reforçado por camisa de concreto de alto desempenho com várias características. Todos os pilares básicos tinham a seção quadrada de 150 mm x 150 mm com altura de 1200 mm. Eles foram produzidos com concreto de 18 MPa de resistência nominal à compressão, armadura longitudinal com quatro barras de 8 mm de diâmetro e armadura transversal com estribos de 6.3mm de diâmetro com espaçamento de 90 mm. Os parâmetros que foram variados nas camisas de reforço foram: a) dois valores de espessura (tj); b) três valores de taxa de armadura transversal (*sw) utilizando telas soldadas ou armadura de estribos; c) adição de fibras curtas de aço. A resistência nominal à compressão do concreto utilizado em todas as camisas foi de 65 MPa, caracterizando-se portanto um concreto de alta resistência. Os pilares foram submetidos à compressão axial por meio de uma máquina hidráulica servo-controlada. Os ensaios foram realizados com controle de deslocamento, adotando-se uma velocidade de 0.005mm/s para o deslocamento do pistão. A força aplicada e as deformações continuaram sendo medidas após o alcance da força de ruína, para se avaliar o comportamento pós-pico, até se atingir uma força residual de cerca de 50% da força de pico. Modelos de cálculo da resistência última dos pilares reforçados foram analisados. Também foram testados modelos de confinamento e ductilidade para os elementos reforçados.
Titre en anglais
Strengthening of reinforced concrete columns by means of high-performance concrete jacketing
Mots-clés en anglais
columns
high-performance concrete
jacketing
steel fiber
strengthening
Resumé en anglais
This study presents the results of an experimental investigation in three series of tests, each one involving two models: a basic reinforced concrete column, which represents the column to ge strengthened, and an identical basic column strengthned by a high-performance concrete jacket with variable characteristics. All the basic columns had a 150 mm x 150 mm square section and a 1,200 mm length. They were made of a 18 MPa nominal strength concrete and reinforced with four 8 mm diameter steel bars and 6.3mm diameter stirrups each. The jacket characteristics varied as follows: a) two thickness values(tj); b) three values of transverse reinforcement ratio (*sw) using welded wire steel meshes or ordinary stirrups; c) addition of short steel fibers. The nominal concrete compressive strength used in all the jackets was 65 MPa, therefore a high-strength concrete. The columns were subjected to monotonic axial compression by means of a servo-controlled hydraulic machine. A displacement increasing rate of 0.005 mm/sec at the top of the column was adopted. Load and strain measurements continued after the ultimate load to evaluate the post-peak behavior, up to a residual load-bearing capacity of about 50% of the peak load. Several calculation hypotheses were tested to evaluate the ultime strength of the rehabilitated columns. Also confinement mechanisms and ductility of the members were analyzed.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Takeuti.pdf (5.90 Mbytes)
Date de Publication
2003-12-02
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.