• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Master's Dissertation
DOI
https://doi.org/10.11606/D.18.2010.tde-06042010-110905
Document
Author
Full name
Hidelbrando José Farkat Diógenes
E-mail
Institute/School/College
Knowledge Area
Date of Defense
Published
São Carlos, 2010
Supervisor
Committee
Hanai, João Bento de (President)
El Debs, Mounir Khalil
Juliani, Marco Antonio Camargo
Title in Portuguese
Análise tipológica de elementos e sistemas construtivos pré-moldados de concreto do ponto de vista de sensibilidade a vibrações em serviço
Keywords in Portuguese
Análise dinâmica
Concreto pré-moldado
Pisos
Protensão
Vibrações
Abstract in Portuguese
No contexto da modernização da construção civil, a aplicação de elementos estruturais de concreto pré-moldado nas construções oferece comprovados benefícios à estratégia de execução das obras, dentre os quais se destacam o atendimento a vãos relativamente grandes, rapidez de montagem, leveza e excelente qualidade dos elementos que compõem a estrutura. Tratando-se especialmente do comportamento dinâmico das estruturas de concreto, os elementos pré-moldados, por apresentarem diversas situações transitórias de solicitação, devem ser avaliados quanto aos efeitos dinâmicos decorrentes da sua produção, transporte, montagem, execução das ligações, finalização da obra e uso. Considerando, nesse contexto, que a protensão é um recurso frequentemente utilizado nos elementos, evidencia-se a necessidade de estudos sobre a sua influência nos parâmetros dinâmicos. Em particular, elementos pré-fabricados protendidos, tais como painéis tipo duplo-T e lajes alveolares, têm sido muito utilizados em pisos de edifícios, todavia e não raras vezes sem uma prévia análise dinâmica quanto à vibração e ao atendimento aos limites de vibração em serviço. O presente trabalho apresenta uma síntese dos procedimentos de cálculo e verificação indicados por normas técnicas do Brasil e do Exterior para a avaliação do conforto humano quanto a vibrações excessivas, assim como os métodos analíticos empregados na determinação da frequência natural de um elemento estrutural, seja ele protendido ou não. Efetuou-se um estudo comparativo dos resultados analíticos com os de uma simulação numérica de painéis duplo-T e lajes alveolares, feita com programa computacional ANSYS, baseado no Método dos Elementos Finitos, sendo eles discutidos quanto ao Estado Limite de Vibrações Excessivas (ELS-VE). Este trabalho apresenta também um estudo experimental sobre um modelo físico de viga de concreto protendido com cabos externos, com o objetivo de demonstrar a aplicação de técnicas de caracterização dos parâmetros dinâmicos e discutir eventuais soluções para o controle ou atenuação de vibrações excessivas. Essa viga foi também analisada numericamente com o programa computacional ANSYS e feita a comparação dos resultados experimentais e numéricos. Conclui-se que, do ponto de vista do ELS-VE, os painéis duplo-T e lajes alveolares particularmente analisados são passíveis de restrições a partir de certos vãos e que, sob determinadas condições ora discutidas, o emprego de tirantes externos, protendidos ou não, podem ser aplicados no controle de vibrações, seja por aumento da rigidez do sistema viga-tirante, seja pelo controle da fissuração do concreto.
Title in English
Typological analysis of precast concrete elements and building systems in terms of sensitivity to vibration in service
Keywords in English
Dynamic analysis
Floors
Precast concrete
Prestressing
Vibrations
Abstract in English
In the context of construction modernization, the application of precast concrete elements offers a good and reliable alternative in the construction strategy, among them large spans, fast assembly, lightweightness and excellent structural members quality. Dealing about dynamic behavior of concrete structures, precast elements are subjected to several loading conditions, from their manufacturing, transport, assembly, connection and finally to service. Prestressing technique is often applied in precast elements, so the influence of prestressing forces on dynamic parameters must be considered. Precast prestressed concrete elements, such as double-T panels and hollow core slabs are commonly used in building floors, but not always a previous dynamic evaluation is accomplished, so vibration problems are likely to occur. This work presents a synthesis of design procedures as recommended by the brazilian and foreign codes regarding to human comfort under vibration conditions. Analytical methods allow the determination of natural frequency of structural elements, being them prestressed or not. Also typical double-T panels and hollow core slabs were analyzed by Finite Element Method (ANSYS software) and analytical and numerical results were compared. A discussion of the results about the Service Vibration Limit State is made. This work also presents an experimental study on a reinforced concrete beam provided with external prestressing tendons. The goal of this study was to demonstrate dynamic tests to characterize dynamic parameters and to discuss vibration control. The tested beam was also simulated on ANSYS to compare theoretical and experimental results. Some conclusions has been drawn, such as typical double-T panels and hollow core slabs may suffer restrictions above certain span dimensions. Also the application of external tendons, with or without prestressing forces may be applied to reduce vibration levels, either by increasing stiffness of the structure or controlling cracking of the concrete beam.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.