• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Doctoral Thesis
DOI
https://doi.org/10.11606/T.18.2010.tde-06052010-105804
Document
Author
Full name
Francisco Aguirre Torrico
E-mail
Institute/School/College
Knowledge Area
Date of Defense
Published
São Carlos, 2010
Supervisor
Committee
Giongo, José Samuel (President)
Carvalho, Roberto Chust
Corrêa, Márcio Roberto Silva
El Debs, Ana Lúcia Homce de Cresce
Melo, Guilherme Sales Soares de Azevedo
Title in Portuguese
Análise teórica e experimental do comportamento de modelos de pilares esbeltos de concreto de alta resistência, considerando a ductilidade
Keywords in Portuguese
Análise não linear
Concreto de alta resistência
Confinamento
Ductilidade
Esbeltez
Pilar
Abstract in Portuguese
Esta tese discute as análises teórica e experimental de pilares de seção retangular, esbeltos, confinados por estribos, de concreto de alta resistência, sujeitos à flexo-compressão, considerando os estados limites últimos de ruptura do concreto ou por deformação excessiva das barras da armadura ou por instabilidade. Foram ensaiados 12 modelos de pilares com esbeltez mecânica igual a 92, compondo três séries de 4 pilares cada uma; os parâmetros estudados foram a excentricidade da força, a taxa volumétrica de armadura transversal e a resistência do concreto. Em uma segunda fase, foram analisados 9 pilares curtos de seção quadrada à compressão concêntrica com o objetivo de avaliar a ductilidade e obter as propriedades do concreto confinado. Para a realização dos ensaios foram empregadas rótulas unidirecionais, que permitiram transferir a força excêntrica ao pilar. Para a obtenção das resistências dos concretos, foram realizados ensaios para a determinação da composição dos materiais e foram traçadas curvas de dosagem. Os resultados experimentais foram comparados com os obtidos com o método exato que considera a não linearidade física e geométrica por meio de programas computacionais elaborados pelo autor. Observou-se que os resultados experimentais se aproximaram dos resultados teóricos. As ruínas dos pilares esbeltos foram por instabilidade, sendo que todos eles atingiram o ponto limite. Foi verificado que a capacidade resistente dos pilares é muito sensível para pequenas variações da excentricidade da força. Nos modelos analíticos foram incorporadas formulações de várias normas que contemplam concretos de alta resistência e o critério de confinamento indicadas pela literatura técnica com algumas modificações. Foi verificada uma pequena melhora na ductilidade ao incrementar a taxa de armadura transversal dos modelos ensaiados. Com os resultados obtidos e com as formulações analisadas, sugere-se uma forma alternativa de projeto de pilares esbeltos.
Title in English
Theoretical and experimental analysis of slender high-strength concrete columns, considering the ductility
Keywords in English
Column
Confinement
Ductility
High-strength concrete
Nonlinear analysis
Slenderness
Abstract in English
This thesis discusses the theoretical and experimental analyses of slender high-strength concrete rectangular columns confinement by lateral reinforcement, subjected to combined axial load and bending, considering the ultimate limit states of concrete crushing at the compressive face or the longitudinal bars excessive deformation or the column instability. Twelve column models were tested with 92 mechanical slenderness. These models included three series of four columns each; the parameters studied were axial load eccentricity, volumetric lateral reinforcement ratio and concrete strength. In a second step, nine square cross section short columns under concentric compression were tested to evaluate ductility and to obtain the confined concrete properties. A pair of unidirectional hinges was used to transfer the eccentric load to the columns. Tests were carried out for material's composition determination and dosage curves were drawn to obtain concrete strengths. The experimental results were compared with those obtained using the exact method that considers physical and geometrical nonlinearities through computational programs prepared by the author. There is not a significant difference between experimental and theoretical results. The instability failure was reach in all columns because of high slenderness, all of they reached the limit point. It was observed that the column ultimate strength is very sensitive for small axial load eccentricity variations. The formulations of several standards codes that consider the high-strength concrete and technical literature confinement criterion with some modifications have been incorporated in the analytical models. A small ductility improvement was observed considering the tests volumetric lateral reinforcement ratio increase. There is an alternative method suggested for slender columns design, based on the obtained results.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
Publishing Date
2010-05-20
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.