Mémoire de Maîtrise
DOI
https://doi.org/10.11606/D.18.2017.tde-06122017-142903
Document
Auteur
Nom complet
Aline Passos de Azevedo
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Carlos, 1999
Directeur
Jury
Hanai, João Bento de (Président)
Furlan Junior, Sydney
Melo, Guilherme Sales Soares de Azevedo
Titre en portugais
Resistência e ductilidade das ligações laje-pilar em lajes-cogumelo de concreto de alta resistência armado com fibras de aço e armadura transversal de pinos
Mots-clés en portugais
Armadura transversal
Concreto de alta resistência
Ductilidade
Fibras de aço
Lajes-cogumelo
Punção
Resumé en portugais
Neste trabalho analisa-se a resistência à punção e a ductilidade das ligações laje-pilar em doze modelos de lajes-cogumelo de concreto armado, nas quais se efetuam combinações de emprego de concreto de alta resistência, diferentes volumes de fibras de aço e uso de armadura transversal na forma de conectores de aço tipo pino. Todas as lajes são quadradas com 1160 mm de lado e 100 mm de espessura. A armadura de flexão foi composta de barras de aço de 10 mm espaçadas de tal forma a resistir a um momento fletor único em ambas direções. Os conectores, quando utilizados, foram dispostos radialmente e compostos de barras de aço de 6.6 mm soldadas a segmentos de ferro chato nas duas extremidades. Para avaliar a capacidade resistente dos modelos de ligação laje-pilar e observar o ganho de ductilidade que as fibras proporcionam, foram ensaiados segmentos-de-laje, os quais representam uma faixa destes modelos de ligação laje-pilar. Foi utilizado um sistema de ensaio dotado de atuador hidráulico servo-controlado, programado para ensaio com deformação controlada e aquisição contínua dos dados, o que permitiu a avaliação do comportamento pós-pico de resistência e a realização de medições de resistência residual. Várias hipóteses de cálculo foram utilizadas para avaliar a resistência última das ligações laje-pilar. Empregou-se um critério de classificação para caracterizar o tipo de ruptura em: punção ou flexão predominante ou uma combinação de punção-flexão. Constatou-se que o emprego de concreto de alta resistência, juntamente com armadura transversal, aumenta substancialmente a resistência da ligação laje-pilar, e quando combinado com fibras de aço, consegue-se um considerável aumento da ductilidade.
Titre en anglais
Resistance and ductiliy of slab-column connections on high strength concrete flat slabs with steel fibers and shear reinforcement
Mots-clés en anglais
Ductility
Flat slab
High strength concrete
Punching shear
Shear reinforcement
Steel fiber
Resumé en anglais
This work analyses the punching shear resistance and ductility of slab-column connections on twelve concrete flat slab models. The model characteristics resulted from combinations of the application of high or ordinary strength concrete, different steel fiber volume fractions and use or not of shear reinforcement. All the slabs are square with 1,160 mm of side and 100 mm of thickness. The main flexural reinforcement was composed of 10 mm steel bars spaced in such a way to resist to the same bending moment in both directions. When used, the shear reinforcement of steel studs were disposed in radial directions and consisted of 6.6 mm steel bars welded to flat steel segments in their ends. To evaluate the resistant capacity of slab-column connection models and to observe the ductility that the fibers provide, they were rehearsed segments-of-slab, which represents a strip of these slab-column connection models. A testing system with a servo-controlled hydraulic jack was used and it was programmed for a controlled deformation test and continuous data acquisition. This method allowed the evaluation of the post-peak strength behavior and the measurement of residual resistance forces. Several calculations hypotheses were used to evaluate the ultimate strength of the slab-column connections. A classification criterium was applied to characterize the failure type as: predominant punching or flexure or a combination of punching-flexure. It was verified that the application of high strength concrete, together with shear reinforcement, increases substantially the slab-column connection strength, and, when combined with steel fibers, a considerable ductility increase is achieved.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Date de Publication
2017-12-07
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.