• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Doctoral Thesis
DOI
10.11606/T.18.2016.tde-12022016-143059
Document
Author
Full name
Alexandre Machado Ferraz
Institute/School/College
Knowledge Area
Date of Defense
Published
São Carlos, 2005
Supervisor
Title in Portuguese
Procedimento de calibração indireta para máquinas de medir a três coordenadas
Abstract in Portuguese
A economia mundial, cada vez mais competitiva, impulsiona o acelerado desenvolvimento tecnológico e conseqüentemente promove o crescente uso de Máquinas de Medir a Três Coordenadas (MM3Cs). A preferência por essas máquinas pode ser justificada pela sua grande flexibiÍidade e produtividade e é uma tentativa de melhorar a área de inspeção dimensional do processo produtivo. Um grande esforço no desenvolvimento de novas metodologias se realiza para se obter e modelar os erros de MM3Cs. Padrões para calibração de MM3Cs foram sugeridos e colocados em uso através dos diferentes anos, com a finalidade de utilizá-los em testes de aceitação e verificação periódica da incerteza de medição de MM3Cs. Novos artefatos para a calibração indireta de MM3Cs visam melhorar os procedimentos de calibração para uso em sistemas de compensação de erros. Diante do exposto acima, este trabalho tem como objetivo desenvolver um Procedimento de Calibração Indireta de MM3Cs com o Esquadro Mecânico de Esferas aliado a um Modelo Reduzido de Sintetização de Erros (MRSE) para uso em um Sistema de Compensação de Erros. O procedimento possibilita maior rapidez na obtenção dos valores e comportamentos dos erros quando comparado com outros procedimentos de calibração indireta. Aliado a um MRSE, o procedimento proposto tem como vantagem o uso de um único artefato para medir todos os termos das componentes do erro volumétrico, nas direções X, Y e Z de uma MM3C.
Title in English
lndirect coordinate measuring machines calibration procedures
Abstract in English
The increasingly competitive world economy promotes the technological development and, as a consequence, the growing use of Coordinate Measuring Machines (CMMs). The predilection for CMMs can be justified by their great flexibility and productivity and is also an attempt to improve the dimerisional inspection quality of the productive process. Considerable effort was made on the development of new methodologies to obtain and model CMMs errors. Calibration standards were suggested and employed for years aiming at acceptance tests and periodic verification of measurement uncertainty of CMMs. The development of new artefacts for CMM indirect calibration seeks to enhance calibration procedures for error compensation systems. Therefore, this work aims at the development of an indirect CMM calibration procedure using a mechanical ball square and the Error Synthesization Reduced Model (ESRM) for an error compensation system. The procedure allows faster obtaining of error values and behaviour if compared with other indirect calibration procedures. The proposed procedure, along with the ESRM, is advantageous since only one artefact is employed to measure all the terms of the volumetric error components m directions X, Y and Z of the CMM.
 
Publishing Date
2016-02-15
 
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2020. All rights reserved.