Disertación de Maestría
DOI
https://doi.org/10.11606/D.18.1998.tde-19062024-121840
Documento
Autor
Nombre completo
Gherhardt Ribatski
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Carlos, 1998
Director
Tribunal
Jabardo, Jose Maria Saiz (Presidente)
Pagliuso, Josmar Davilson
Yanagihara, Jurandir Itizo
Título en portugués
Estudo da transferência de calor em ebulição nucleada de refrigerantes halogenados
Palabras clave en portugués
ebulição nucleada
misturas refrigerante/óleo
refrigerantes halogenados
superfícies intensificadoras
Resumen en portugués
A otimização do projeto de evaporadores inundados para aplicações frigoríficas requer a adequada determinação do coeficiente de transferência de calor em ebulição nucleada. Este trabalho, através da literatura aberta, visou um extenso estudo do coeficiente de transferência de calor, revelando dois tipos de correlações: (1) estritamente empíricas, baseadas no ajuste da curva à bancos de dados experimentais; (2) semi-empíricas, baseadas em modelos físicos, mas com ajuste de coeficientes numéricos aos dados experimentais. Foram verificadas significativas discrepâncias entre as correlações, refletindo o ponto de vista do autor com relação ao mecanismo físico da ebulição nucleada ou tendências particulares dos dados experimentais. Em adição à pesquisa bibliográfica, foi realizada uma análise preliminar do procedimento de Cooper com o desenvolvimento de uma correlação para refrigerantes halogenados. Esta foi determinada utilizando dois diferentes bancos de dados compostos por refrigerantes de baixa pressão, tais como R-11, R-113 e R-114. Tal procedimento, necessitou o desenvolvimento de correlações para as propriedades de transporte dos refrigerantes escritas em termos da temperatura e pressão reduzidas. Estas são caracterizadas pela simplicidade e precisão, adequando-se à diferentes refrigerantes pela simples alteração de coeficientes numéricos. Finalmente, analisou-se dois importantes aspectos na ebulição nucleada de refrigerantes: os efeitos do óleo de lubrificação do compressor e as superfícies intensificadoras da transferência de calor
Título en inglés
Study of nucleate pool boiling heat transfer of halogened refrigerants
Palabras clave en inglés
enhancement surfaces
halogened refrigerants
mixtures refrigerants/oil
pool boiling
Resumen en inglés
The optimized design of flooded evaporators for refrigeration applications requires na adequate determination of the mucleate pool boiling heat transfer coefficient of the refrigerant. This study has been focused on na extensive analysis of the aforementioned heat transfer coefficient. A literature survey has revealed two types of correlations: (1) strictly empirical, based on experimental data bank curve fitting; and (2) semi-empirical, based on physical model but with numerical coefficients fitted with experimental data. Significant discrepancies have been noted between correlations, reflecting either the point of view of the author regarding the physical mechanism of nucleate boiling or particular trends of experimental data. In addition to the literature survey , a preliminary analysis of the Coopers procedure has been performed with the development of a correlation for halogen refrigerants, based on data obtained elsewhere from two different experimental set ups involving low pressure refrigerants such as the R-11, R-113 and R-114. This procedure requires correlations of the transport properties of the refrigerants written in terms of reduced pressure and temperature. Correlations developed in this study are straightforward, accurate and fitted to different refrigerants by simply changing numerical coefficients. Finally, an analysis of two important aspects of the nucleate boiling phenomena of refrigerants has been performed, namely those related to effects on the heat tran_sfer coefficient of the compressor lubrication oleo and heat transfer enhancement devices.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2024-06-19
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.