• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Mémoire de Maîtrise
Document
Auteur
Nom complet
Arnaldo Sarti
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Carlos, 1998
Directeur
Jury
Foresti, Eugenio (Président)
Júnior, Deovaldo de Moraes
Pires, Eduardo Cleto
Titre en portugais
Avaliação de desempenho do reator anaeróbio horizontal de leito fixo (RAHLF) no tratamento de substrato sintético simulando esgoto doméstico
Mots-clés en portugais
esgoto sanitário
processo anaeróbio
reator anaeróbio horizontal de leito fixo
transferência de massa
Resumé en portugais
Este trabalho apresenta e discute os resultados obtidos durante a operação de um Reator Anaeróbio Horizontal de Leito Fixo (RAHLF) de bancada, alimentado com substrato sintético simulando esgoto sanitário. O RAHLF tem relação comprimento/diâmetro(L/D) aproximado de 20 e é preenchido com matrizes cúbicas de espuma de poliuretano de aproximadamente 1/10 de D contendo lodo anaeróbio imobilizado. O monitoramento do desempenho do reator inclui a determinação de demanda química de oxigênio(DQO), pH, sólidos em suspensão voláteis (SSV), ácidos voláteis totais (AVT) e alcalinidade no afluente, no efluente e em pontos de amostragens intermediários. Foram aplicados tempos de detenção hidráulico (TDH) de 10,0; 5,0; 3,3; 2,5 e 2,0horas, fixados de modo a se obter, em todos os ensaios, TDH de 2,0 horas em um dos pontos de coleta de amostras. As velocidades superficiais de líquido ('V IND.S') correspondentes foram, respectivamente, 10, 20, 30, 40 e 50 cm. 'h POT.-1'. A ficiência de remoção de DQO foi superior a 80% após um curto período de partida (menos de 15 dias), para todos os experimentos, conforme as mudanças nas condições operacionais. As determinações de DQO nas amostras coletadas nos pontos de amostragem correspondentes ao TDH de 2,0 horas apresentou valores decrescentes com aumento de 'V IND.S' (150, 121, 100, 80 e 73 mg de substrato. Essa influência foi quantificada por meio de determinação dos coeficientes de transferência de massa na fase líquida ('k IND.5'), para cada 'V IND.S' aplicada. A partir desses valores, obteve-se uma expressão que relaciona 'k IND.5' em função de 'V IND.S' para o RAHLFDQO.'L POT.-1'), demonstrando que o fenômeno de transferência de massa na fase líquida exerce grande influência nataxa de remoção
Titre en anglais
.
Mots-clés en anglais
anaerobic process
domestic sewage
horizontal flow anaerobic immobilized sludge reactor
mass transfer
Resumé en anglais
The results obtained from operation of a bench-scale horizontal-flow anaerobic immpbilized sludge (HAIS) reactor fed with synthetic substrate simulating domestic sewage are presented and discussed. The HAIS reactor with a length/diameter (L/D) ratio of 20 is filled with polyurethane foam matriees containing immobilized anaerobic sludge. The reactor performance monitoring included the determination of Chemical oxigen demand (COD), pH, volatile suspended solids (VSS), total volatile a;cids (TVA) and alkalinity (A) in the influent, effluent and intermediate port samples. Hydraulic detention times (HDT) of 10.0, 5.0, 3.3, 2.5 and 2.0 hours were applied in order to obtain the HDT of 2.0 hours in one of the sampling ports. The liquid superficial velocities (Vs) were, respectively, 10, 20, 30, 40 and 50 cm/hr. COD removal efficiencies were higher than 80% after a short transient period (lower than 15 days) following the changes in the óperational conditions. COD values of the sampling portS corresponding to the HDT of 2.0 hours decreased with the increase of Vs, achieving the values of 150, 121, 100, 80 and 73 mgDQO/L. Therefore, mass transfer in the liquid-phase was found to excert a great influence in the substrate removal rate. Such an influence was quantified by determining the liquid-phase mass transfer coefficients (kg) for each Vs applied. The values of ks obtained permitted to express kg as function of Vs for HAIS reactor.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Date de Publication
2024-06-14
 
AVERTISSEMENT: Le matériau se réfère à des documents provenant de cette thèse ou mémoire. Le contenu de ces documents est la responsabilité de l'auteur de la thèse ou mémoire.
  • Sarti, Arnaldo, et al. Full-scale anaerobic sequencing batch biofilm reactor for sulfate-rich wastewater treatment [doi:10.5004/dwt.2011.1864]. Desalination and Water Treatment [online], 2011, vol. 25, p. 13-19.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.