• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Disertación de Maestría
DOI
https://doi.org/10.11606/D.18.2014.tde-10102014-131806
Documento
Autor
Nombre completo
Antonio Wagner Lamon
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Carlos, 2014
Director
Tribunal
Campos, José Roberto (Presidente)
Calijuri, Maria do Carmo
Sarti, Arnaldo
Título en portugués
Aplicação de microssensores no monitoramento de oxigênio dissolvido, potencial REDOX e temperatura em estudos limnológicos
Palabras clave en portugués
Microssensor
Monitoramento ambiental
Oxigênio dissolvido
POR
Resumen en portugués
A importância do monitoramento de parâmetros físico-químicos e biológicos no meio ambiente torna-se cada vez mais evidenciada quando se busca o entendimento dos processos que ocorrem na natureza, sejam eles decorrentes de ações antrópicas ou naturais, ou ainda, como efetivo auxilio na gestão de ecossistemas aquáticos. Entre os parâmetros de interesse no monitoramento do meio aquático, o oxigênio dissolvido (OD) é, indubitavelmente, uma das variáveis fundamentais na caracterização de ecossistemas, pois este elemento está intimamente ligado à capacidade de respiração de peixes, plantas e de micro-organismos. Assim como o OD, o Potencial de Oxido- Redução (POR) assume papel importante no monitoramento de ambientes aquáticos, pois se relaciona com reações químicas óxido-redutoras e bioquímicas. Ainda, nesse contexto, a temperatura interfere significativamente nas taxas em que ocorrem as reações químicas e bioquímicas. Devido à importância desses parâmetros para o monitoramento ambiental, o presente trabalho teve como objetivo o desenvolvimento de microssensores eletroquímicos amperométricos para medição de oxigênio dissolvido (OD) tipo Clark, potenciométricos para medição de POR e de temperatura, bem como, sistemas eletrônicos compactos para leitura e software para visualização e armazenamento de dados de maneira autônoma, por meio de notebook ou PC. O sistema de aquisição conta com um módulo GPS para registro das coordenadas dos pontos de aquisição e módulo GPRS para transmissão de dados via celular. Foram desenvolvidos eletrodos com base na tecnologia de microssensores utilizados em estudos de biofilmes; recentemente introduzidos no Brasil e desenvolvidos no Departamento de Hidráulica e Saneamento da Escola de Engenharia de São Carlos da Universidade de São Paulo desde 2007, mediante apoio da Universidade de Montana EUA e FAPESP. O método proposto para sua fabricação visa produção com custos minimizados, podendo atingir 50% dos custos de sistemas convencionais para o mesmo propósito; isso decorre da miniaturização de componentes internos, pois assim como nos macro eletrodos, são empregados metais nobres como ouro, platina e prata. Os microssensores, sistemas eletrônicos e software foram validados através de testes de desempenho em laboratório. Em campo, foram avaliados por meio de medições realizadas no reservatório do Lobo (Itirapina - SP), para obtenção de dados limnológicos do reservatório, onde foram aquisicionados perfis de OD, POR e temperatura por meio de um traçado longitudinal com embarcação de pequeno porte e os pontos de medição foram vinculados às coordenadas GPS ao longo do trajeto do levantamento. Na foz dos principais afluentes do reservatório, foram coletadas amostras para análises complementares, buscando identificar alterações antrópicas e os níveis de trofia do reservatório para Fósforo Total e Profundidade (Secchi ZDS). Foi também observada a distribuição espaciais da comunidade fitoplanctônica.
Título en inglés
Application of microsensors in the monitoring of dissolved oxygen, redox potential and temperature in limnological studies
Palabras clave en inglés
Dissolved oxygen
Environmental monitoring
ORP
Resumen en inglés
The importance of the physicochemical and biological monitoring parameters in the environment becomes more and more evidenced when the understanding of the processes is looked at what happens in nature, whether they are from anthropic or natural actions. Among the parameters of interest in the aquatic mean monitoring, dissolved oxygen (DO) is undoubtedly, one of the fundamental items in the characterization of aquatic ecosystems, because this element is intimately linked to the breathing capacity of fish, plants and microorganisms of oxidizing substances present on that media. As well as DO, the ORP assumes an important role in aquatic monitoring, acting in the levels of oxide reduction and biochemical reactions that happen. Still, in that context, the temperature represents effective interference in the rates where chemical and biochemical reactions take place in the environment, even in the ones that concern DO and ORP. Due to the importance of these parameters for the environmental monitoring to better know the appropriate conditions and to plan solutions the present work seeks the development of amperometric electrochemistry micro electrodes for dissolved oxygen (DO) measurement Clark type, potentiometric for ORP measurement and temperature with the LM35component, as well as, compact electronic systems for reading and software for visualization and storage of data in an autonomous way, through notebook or PC. Yet, the data acquisition system foresees the application of a GPS module for data acquisition recordings of the coordinates points and a GPRS module for data transmission from cellular. The electrodes were developed based on the microsensors technology used in biofilms studies; recently introduced in Brazil and developed at the Hydraulics and Sanitation Department at School of Engineering of São Carlos at the São Paulo State University since 2007, through the support of the Montana State University USA and FAPESP. The proposed method for construction seeks production with minimized costs, it could reach 50% of the conventional systems costs for the same purpose, due to the internal components miniaturization, because as well as for macro electrodes, noble metals are used as gold, platinum and silver. The microsensors, electronic systems and software were validated through the tests carried out at the laboratory and through comparison with commercially found electrodes. In the field, they will be evaluated through acting tests in measurements carried out at the Lobo Reservoir (Itirapina SP Brazil), throughout the whole reservoir by using a small boat and the data acquisitions points were indexed to the GPS coordinate along the trajectory. Samples were collected at the main affuents of the reservoir for additional analysis, seeking identification of anthropic changes as well as the trophic level of the reservoir for Phosphorus and depth of the Secchi disk (ZDS). It was also observed the spatial distribution of phytoplankton community.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2014-10-30
 
ADVERTENCIA: El material descrito abajo se refiere a los trabajos derivados de esta tesis o disertación. El contenido de estos documentos es responsabilidad del autor de la tesis o disertación.
  • LAMON, A. W., et al. Automação de Reator de Leito Expandido em Escala Plena com Zonas Anaeróibia e Aeróbia Sobrepostas para Tratamento de Esgoto Sanitário. Tecno-Lógica (UNISC), 2008, vol. 12, p. 17-30.
  • LAMON, A. W., SARTI, A., e CAMPOS, J. R. Microssensores: Ferramentas de Alta Tecnologia. HYDRO - Ed. Aranda. Saneas (São Paulo), 2007, vol. Ano 2, p. 42-45.
  • CAMPOS, J. R., et al. Análise da Nitrificação em Biofilmes por Meio de Microssensores. Hydro (São Paulo), 2011, vol. I, p. 44-49.
  • GONZALEZ, B. C., et al. The Use of Microsensors to Study the Role of the Loading Rate and Surface Velocity on the Grow and the Composition of Nitrifying Biofilm. Water Science and Technology, 2011, vol. 64, p. 1607-1613.
  • GONZALEZ, B. C., et al. Microscopic Sensors for Oxigen Measurements at Air-Water Interfaces and in Sediment Biofilms. In The 6th International Symposium on Gas Transfer at Water Surfaces, Kyoto - Japan, 2010. The 6th International Symposium on Gas Transfer at Water Surfaces.Kyoto - Japan : Komori, S.; Mc. Gillis; R. Kurosp, 2010.
  • LAMON, A. W., et al. Automação de Reator de Leito Expandido Aplicado ao Tratamento de Esgoto Sanitário. In 24o. Congresso Brasileiro de Engenharia Sanitária e Ambiental, Belo Horizonte - MG, 2007. Anais do 24o. Congresso Brasileiro de Engenharia Sanitária e Ambiental., 2007.
  • LAMON, A. W., et al. Confecção, Avaliação e Aplicação de Microsensores de Oxigênio Dissolvido para Estudo de Biofilmes. In 24o. Congresso Brasileiro de Engenharia Sanitária e Ambiental, Belo Horizonte-MG, 2007. 24o. Congresso Brasileiro de Engenharia Sanitária e Ambiental., 2007.
  • LAMON, A. W., et al. Sistema Avançado para Avaliação de Crescimento de Biofilme Anaeróbio/Aeróbio por Meio de Microsensores. In XXXI Congreso Interamericano de Ingenieria Sanitária y Ambiental - AIDIS - Associación Interamericana de Ingenieria Sanitária y Ambiental, Santiago - Chile, 2008. XXXI Congreso Interamericano de Ingenieria Sanitária y Ambiental - AIDIS - Associación Interamericana de Ingenieria Sanitária y Ambiental., 2008.
  • GONZALEZ, B. C., LAMON, A. W., and CAMPOS, J. R. Biofuel Cell on a Wastewater Treatment System with Anaerobic/Aerobic Reactor. In Congresso 'Asset Management for Enchancing Energy Efficiency in Water and Wastewater Systems', Marbella - Espanha, 2013. Asset Management for Enchancing Energy Efficiency in Water and Wastewater Systems.Londres - UK : International Water Association - IWA, 2013.
  • GONZALEZ, B. C., LAMON, A. W., e CAMPOS, J. R. Reator de Bancada do Tipo Célula de Fluxo para Estudo de Biofilmes Aeróbios Mediante o Uso de Microssensores. In X Simpósio Italo Brasileiro de Engenharia Sanitária e Ambiental - SIBESA, Maceió - Alagoas, 2010. X Simpósio Italo Brasileiro de Engenharia Sanitária e Ambiental - SIBESA., 2010.
  • GONZALEZ, B. C., LAMON, A. W., e CAMPOS, J. R. Verificação da Ocorrência da Nitrificação em Biofilmes Aeróbio por Meio do Uso de Microssensores. In X Simpósio Italo Brasileiro de Engenharia Sanitária e Ambiental - SIBESA, Maceió - Alagoas, 2010. X Simpósio Italo Brasileiro de Engenharia Sanitária e Ambiental - SIBESA., 2010.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.