• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Mémoire de Maîtrise
DOI
https://doi.org/10.11606/D.18.2008.tde-08052024-161915
Document
Auteur
Nom complet
Fausto Enokibara
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Carlos, 2008
Directeur
Jury
Canale, Lauralice de Campos Franceschini (Président)
Casteletti, Luiz Carlos
Motheo, Artur de Jesus
Titre en portugais
Caracterização superficial e análise da resistência à corrosão de ligas de titânio em meios fluoretados
Mots-clés en portugais
corrosão
fluoreto
ligas de titânio
saliva artificial
titânio
Resumé en portugais
O titânio e suas ligas são empregados em odontologia por apresentarem propriedades como excelente resistência à corrosão e biocompatibilidade. Embora a liga de titânio Ti-6Al-4V seja uma das mais utilizadas, estudos recentes contestam a biocompatibilidade do alumínio e do vanádio. Esse fato tem motivado a busca por outras ligas de titânio, como as ligas do sistema Ti-Mo. Este trabalho avalia a resistência à corrosão da liga Ti-10Mo, comparativamente à liga Ti-6Al-4V, em diferentes meios fisiológicos. Estuda a influência exercida por um meio similar à saliva, além de avaliar o comportamento devido à presença de íons fluoreto e de um meio ácido. A relação entre resistência à corrosão e porcentagem de molibdênio das ligas do sistema Ti-Mo foi analisada através da comparação entre as ligas Ti-10Mo e Ti-7,5Mo. Foi verificado também o motivo pelo qual o aço inoxidável austenítico AISI 316L, utilizado em implantes ortopédicos, não possui aplicação em implantes odontológicos. O comportamento dos óxidos formados nas ligas Ti-6Al-4V e Ti-10Mo nos eletrólitos estudados foi avaliado através das técnicas de EDX e XPS. Os resultados mostram que a resistência à corrosão das ligas de titânio estudadas tornam possível sua utilização em implantes dentários desde que obedeçam requisitos como a biocompatibilidade, mas a influência dos íons fluoreto e baixos valores de pH tornam-nas suscetíveis à corrosão. A avaliação superficial mostrou que existe uma variedade de óxidos para as ligas Ti-6Al-4V e Ti-10Mo antes da polarização. Após a polarização, a liga Ti-6Al-4V apresenta somente o óxido TiO2 enquanto que a liga Ti-10Mo apresenta uma variedade de óxidos de molibdênio permitindo uma melhor resistência à corrosão nesta condição
Titre en anglais
Caracterização superficial e análise da resistência à corrosão de ligas de titânio em meios fluoretados
Mots-clés en anglais
artificial saliva
corrosion
fluoride
pH
titanium
titanium alloys
Resumé en anglais
Titanium and its alloys are used in dentistry because of their excellent properties as corrosion resistance and biocompatibility. Although the Ti-6Al-4V alloy has been widely used, recent works have demonstrated deleterious effects of aluminum and vanadium. This fact has been motivated the demand for other titanium alloys as TiMo system. The aim of this study is to evaluate the corrosion resistance of Ti-10Mo comparing with Ti-6Al-4V performance in different body fluid environment. Study the influence of a salivary environment and the corrosion behavior in the presence of fluoride contents and different pH values. The relation between corrosion resistance and molybdenium contents in TiMo alloys was analyzed through a comparative study between Ti-10Mo and Ti-7,5Mo. It was verified the reason for the austenitic stainless steel AISI 316L widely used in orthopedic implants has not been recommended in dentistry. X-Ray electron spectroscopy (XPS) and scanning electron microscopy (SEM) were undertaken to study the elemental composition and structure of the surface films after and before the potencyodinamic polarization in acid-fluoride salivary solution. The results showed that the corrosion resistance of both alloys turns possible their use in dentistry since the biocompatibility had been proved, but the fluoride influence and low values of pH turn the alloys susceptible to corrosion. The XPS tests before the polarization showed a variety of titanium oxides for both alloys and only the presence of TiO2 after the polarization, but for the Ti-10Mo the XPS showed a variety of molybdenum oxides after polarization giving the better corrosion resistance in the acid-fluoride salivary solution than Ti-6Al-4V
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Date de Publication
2024-05-08
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.