Mémoire de Maîtrise
DOI
https://doi.org/10.11606/D.18.2009.tde-06042009-152204
Document
Auteur
Nom complet
Leandro Augusto Lopes Azeka
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Carlos, 2009
Directeur
Jury
Paiva, Maria Stela Veludo de (Président)
Gonçalves, Arthur Lopes
Rodrigues, Evandro Luis Linhari
Titre en portugais
Analisador de bilirrubina no soro de neonatos utilizando espectrofotometria direta
Mots-clés en portugais
Bilirrubina
Bilirrubinômetro
Espectrofotometria
Icterícia
Medição de bilirrubina
Resumé en portugais
A icterícia é uma manifestação caracterizada pelo amarelamento da pele e mucosas devido ao excesso de bilirrubina no sangue do paciente. Cerca de 60% dos recém nascidos (RN) manifestam a icterícia nas primeiras semanas de vida, sendo este índice muito maior em neonatos prematuros. Se não corretamente diagnosticada, a alta concentração de bilirrubina pode intoxicar a massa encefálica, provocando uma encefalopatia conhecida como kernicterus. Existem vários métodos para medir a concentração de bilirrubina, e entre eles pode-se citar: métodos bioquímicos laboratoriais que utilizam amostras de sangue coletadas e reagentes específicos, medidores de bilirrubina transcutâneos e espectrofotometria em amostras de soro. O princípio básico desses métodos é a análise colorimétrica, que se baseia na alta absorbância da molécula de bilirrubina no comprimento de onda de 455 nm. O presente trabalho descreve um bilirrubinômetro, que foi desenvolvido para medir a concentração da bilirrubina utilizando a espectrofotometria direta no soro de amostras sanguíneas de neonatos. No projeto do bilirrubinômetro levou-se em consideração o baixo custo de produção, uma boa precisão comparada com outros equipamentos, e a utilização de componentes de alta tecnologia tais como LED com alta intensidade luminosa e fotorreceptores especiais para medir concentrações nas faixas de luz específica. Para a validação do equipamento foram obtidas amostras de sangue de recém nascidos, junto ao Hospital das Clínicas da Faculdade de Medicina de Ribeirão Preto, e os resultados das medidas realizadas com o bilirrubinômetro construído foram comparados com os obtidos com um bilirrubinômetro comercial e com métodos bioquímicos clássicos. Os resultados da comparação mostraram que o bilirrubinômetro construído apresenta um erro relativo de ± 1,05 mg/dl, que se encontra dentro da média dos bilirrubinômetros diretos e custo de produção relativamente baixo.
Titre en anglais
Neonate serum bilirubin meter using direct spectrophotometry
Mots-clés en anglais
Bilirubin
Bilirubin meter
Bilirubinometer
Direct spectrophotometry
Spectrophotometry
Resumé en anglais
Jaundice is a manifestation described as the yellowish staining of the skin and mucous membranes caused by the excessive levels of bilirubin in the patient blood. About 60% of the newborns present this feature in the first weeks of life, and this percentage is much higher in premature neonates. If not correctly detected and treated, the bilirubin can intoxicate the encephalic mass, causing an encephalopathy knowed as kernicterus. There are many methods to measure the bilirubin concentration such as: blood laboratory methods using specific reagents, transcutaneous bilirubin and serum spectrophotometric equipments. The basic principle of these devices is the colorimetric analysis based on the high absorption of the bilirubin molecule in the 455 nm wavelength. This work describes a bilirubin meter that was developed for measure the bilirubin concentration using direct spectrophotometry in the serum of neonates' blood samples. In the bilirubin meter project it was considered the low production cost, a good precision compared with others similar equipments, and the use of high technology components as high intensity LED and special photoreceptors to measure specific wavelengths. For validation of the equipment it was used newborns blood samples from the Clinics Hospital at the Faculty of Medicine of Ribeirão Preto, and the results obtained with the equipment were compared with the values of a commercial bilirubin meter and with biochemical tests. The results showed that the developed bilirubin meter has a relative error around 1,05 mg/dl, similar to commercial bilirubin meters and a low relative cost.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Azeka.pdf (3.53 Mbytes)
Date de Publication
2009-04-23
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.