Mémoire de Maîtrise
DOI
https://doi.org/10.11606/D.18.2009.tde-17112009-085705
Document
Auteur
Nom complet
Giuliano Rossi
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Carlos, 2009
Directeur
Jury
Ventura, Liliane (Président)
Costa, Rogerio Alves
Oliveira, Maria Cristina Ferreira de
Titre en portugais
Desenvolvimento de cavidade laser em 532nm para uso oftalmológico
Mots-clés en portugais
DPSSL
Fotocoagulação
Laser verde
Oftalmologia
Retina
SHG
Resumé en portugais
O presente trabalho trata-se do desenvolvimento de uma cavidade Laser de estado sólido e geração de segundo harmônico, para fins oftalmológicos. A cavidade faz parte de um projeto maior que se refere a um fotocoagulador portátil, utilizado em diversos protocolos clínicos relacionados às doenças da retina e câmara anterior, como retinopatia diabética, retinopatia da prematuridade, glaucoma, edema macular e descolamento de retina. A cavidade proposta é composta por três espelhos dispostos em uma arquitetura em V. Um laser de diodo bombeia um cristal de Nd:YAG para a geração de laser em 1064nm que passa por um cristal de KTP para a geração de segundo harmônico em 532nm (laser verde). O sistema de acoplamento indexado à cavidade acopla até 90% da potência de saída em uma fibra óptica com núcleo de 100'mü'm. A cavidade projetada e implementada, produz um feixe com comprimento de onda de 532nm (laser verde), largura de banda de 0,5nm, potência máxima em torno de 2,5W na saída da fibra óptica e pulsos com duração máxima de 3s, que são requisitos para os tratamentos oftalmológicos associados a este tipo de equipamento. É importante destacar que a cavidade foi projetada e desenvolvida inteiramente com tecnologia nacional, sendo o primeiro trabalho desenvolvido no Brasil, que se tornou efetivamente um equipamento final para uso clínico. Além do projeto da cavidade laser, são descritos neste trabalho os sistemas mecânico e eletrônico, que possibilitaram seu funcionamento na integração do fotocoagulador. O fotocoagulador foi testado em pacientes voluntários da Escola Paulista de Medicina da UNIFESP, apresentando resultados comparáveis aos sistemas importados.
Titre en anglais
Development of a 532nm laser cavity for ophthalmology applications
Mots-clés en anglais
DPSSL
Green laser
Ophthalmology
Photocoagulation
Retina
SHG
Resumé en anglais
This work presents the research and the development of a solid state laser cavity with second harmonic generation for ophthalmological purpose. The laser cavity is part of a major project intended to produce a handle photocoagulator. This medical equipment is applied in several clinical protocols related to retinal and anterior chamber pathologies, such as diabetic retinopathy, retinopathy of prematurity, glaucoma, macular edema and retinal detachment. The present cavity is composed by three mirrors disposed in a V shape architecture. One laser diode pumps the Nd:YAG crystal to generate the 1064nm laser that is converted by second harmonic generation in 532nm through the KTP crystal (green laser). The coupling system attached in the cavity is able to collimate until 90% of the laser beam inside a optical fiber with 100 'mü'm core. The developed cavity produces a beam with wavelength of 532nm, spectral width of 0.5nm, maximum power around 2.5W in the end of the optical fiber and maximum pulse duration of 3s. Those parameters are requirements for ophthalmological treatments related to this kind of equipment. It is important to declare that the cavity was projected and developed in Brazil. This is the first work in this country that becomes effectively a device to clinical application. Besides the cavity design project, in this work also describes the mechanical and electronic sub systems that was responsible to the laser control and photocoagulator assembler. This product was tested in patients eyes from UNIFESP (Escola Paulista de Medicina), and showed similar results compared to the systems on the market.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Giuliano.pdf (3.41 Mbytes)
Date de Publication
2009-11-24
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.