• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Dissertação de Mestrado
DOI
https://doi.org/10.11606/D.18.2009.tde-17112009-085705
Documento
Autor
Nome completo
Giuliano Rossi
Unidade da USP
Área do Conhecimento
Data de Defesa
Imprenta
São Carlos, 2009
Orientador
Banca examinadora
Ventura, Liliane (Presidente)
Costa, Rogerio Alves
Oliveira, Maria Cristina Ferreira de
Título em português
Desenvolvimento de cavidade laser em 532nm para uso oftalmológico
Palavras-chave em português
DPSSL
Fotocoagulação
Laser verde
Oftalmologia
Retina
SHG
Resumo em português
O presente trabalho trata-se do desenvolvimento de uma cavidade Laser de estado sólido e geração de segundo harmônico, para fins oftalmológicos. A cavidade faz parte de um projeto maior que se refere a um fotocoagulador portátil, utilizado em diversos protocolos clínicos relacionados às doenças da retina e câmara anterior, como retinopatia diabética, retinopatia da prematuridade, glaucoma, edema macular e descolamento de retina. A cavidade proposta é composta por três espelhos dispostos em uma arquitetura em V. Um laser de diodo bombeia um cristal de Nd:YAG para a geração de laser em 1064nm que passa por um cristal de KTP para a geração de segundo harmônico em 532nm (laser verde). O sistema de acoplamento indexado à cavidade acopla até 90% da potência de saída em uma fibra óptica com núcleo de 100'mü'm. A cavidade projetada e implementada, produz um feixe com comprimento de onda de 532nm (laser verde), largura de banda de 0,5nm, potência máxima em torno de 2,5W na saída da fibra óptica e pulsos com duração máxima de 3s, que são requisitos para os tratamentos oftalmológicos associados a este tipo de equipamento. É importante destacar que a cavidade foi projetada e desenvolvida inteiramente com tecnologia nacional, sendo o primeiro trabalho desenvolvido no Brasil, que se tornou efetivamente um equipamento final para uso clínico. Além do projeto da cavidade laser, são descritos neste trabalho os sistemas mecânico e eletrônico, que possibilitaram seu funcionamento na integração do fotocoagulador. O fotocoagulador foi testado em pacientes voluntários da Escola Paulista de Medicina da UNIFESP, apresentando resultados comparáveis aos sistemas importados.
Título em inglês
Development of a 532nm laser cavity for ophthalmology applications
Palavras-chave em inglês
DPSSL
Green laser
Ophthalmology
Photocoagulation
Retina
SHG
Resumo em inglês
This work presents the research and the development of a solid state laser cavity with second harmonic generation for ophthalmological purpose. The laser cavity is part of a major project intended to produce a handle photocoagulator. This medical equipment is applied in several clinical protocols related to retinal and anterior chamber pathologies, such as diabetic retinopathy, retinopathy of prematurity, glaucoma, macular edema and retinal detachment. The present cavity is composed by three mirrors disposed in a V shape architecture. One laser diode pumps the Nd:YAG crystal to generate the 1064nm laser that is converted by second harmonic generation in 532nm through the KTP crystal (green laser). The coupling system attached in the cavity is able to collimate until 90% of the laser beam inside a optical fiber with 100 'mü'm core. The developed cavity produces a beam with wavelength of 532nm, spectral width of 0.5nm, maximum power around 2.5W in the end of the optical fiber and maximum pulse duration of 3s. Those parameters are requirements for ophthalmological treatments related to this kind of equipment. It is important to declare that the cavity was projected and developed in Brazil. This is the first work in this country that becomes effectively a device to clinical application. Besides the cavity design project, in this work also describes the mechanical and electronic sub systems that was responsible to the laser control and photocoagulator assembler. This product was tested in patients eyes from UNIFESP (Escola Paulista de Medicina), and showed similar results compared to the systems on the market.
 
AVISO - A consulta a este documento fica condicionada na aceitação das seguintes condições de uso:
Este trabalho é somente para uso privado de atividades de pesquisa e ensino. Não é autorizada sua reprodução para quaisquer fins lucrativos. Esta reserva de direitos abrange a todos os dados do documento bem como seu conteúdo. Na utilização ou citação de partes do documento é obrigatório mencionar nome da pessoa autora do trabalho.
Giuliano.pdf (3.41 Mbytes)
Data de Publicação
2009-11-24
 
AVISO: Saiba o que são os trabalhos decorrentes clicando aqui.
Todos os direitos da tese/dissertação são de seus autores
CeTI-SC/STI
Biblioteca Digital de Teses e Dissertações da USP. Copyright © 2001-2024. Todos os direitos reservados.