Thèse de Doctorat
DOI
https://doi.org/10.11606/T.18.2017.tde-18122017-093612
Document
Auteur
Nom complet
Leonardo Bruno Garcia Campanhol
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Carlos, 2017
Directeur
Jury
Silva, Sérgio Augusto Oliveira da (Président)
Coelho, Ernane Antonio Alves
Machado, Ricardo Quadros
Marafão, Fernando Pinhabel
Morais, Lenin Martins Ferreira
Titre en portugais
Sistema fotovoltaico trifásico de único estágio conectado a sistemas de geração distribuída operando como condicionador de qualidade de energia unificado usando uma estratégia dual de compensação ativa de potência
Mots-clés en portugais
Capacidade de filtragem universal
Estratégia de controle dual
Geração distribuída de energia
Qualidade da energia elétrica
Sistema PV-UPQC
Sistemas fotovoltaicos
Resumé en portugais
Este trabalho propõe um sistema fotovoltaico (PV) multifuncional conectado a um sistema elétrico trifásico a quatro fios e operando com estratégia dual de compensação ativa de potência. Além da injeção de potência ativa na rede elétrica, o sistema PV operara como um condicionador unificado de qualidade de energia (UPQC) suprimindo as correntes harmônicas da carga e compensando a potência reativa. Adicionalmente, tensões balanceadas, reguladas e livre de harmônicos são fornecidas para a carga. O sistema PV-UPQC é baseado em uma estratégia de compensação dual, na qual o conversor série opera como uma fonte de corrente senoidal, enquanto o conversor paralelo atua como uma fonte de tensão senoidal. Como resultado, nenhum comportamento transitório é observado na troca entre os modos de operação ilhado e interconectado do sistema PV-UPQC. Além disso, para contornar os problemas associados às mudanças bruscas de irradiação solar, uma malha de controle feed-forward atua na geração das referências de corrente do conversor série, de modo que se obtenha um rápido balanço de potência entre o sistema PV e a rede elétrica. Como resultado, as respostas dinâmicas tanto da corrente elétrica quanto da tensão do barramento CC são melhoradas. A análise detalhada envolvendo o fluxo de potência ativa dos inversores é realizada proporcionando um melhor entendimento sobre a operação do sistema PV-UPQC, bem como auxiliando no dimensionamento dos conversores de potência. Resultados de simulação e experimentais são apresentados para avaliar os desempenhos estáticos e dinâmicos do PV-UPQC conectado ao sistema elétrico de distribuição.
Titre en anglais
Single-stage three-phase grid-tied photovoltaic system operating as an universal power quality conditioner with dual compensation strategy
Mots-clés en anglais
Distributed generation system
Dual compensating strategy
Photovoltaic systems
Power quality
PV-UPQC system
Universal filtering capability
Resumé en anglais
This work proposes a multifunctional single-stage three-phase four-wire grid-connected photovoltaic (PV) system operating with a dual active power-line compensating strategy. Besides injection of active power into the grid, the PV system operates as a unified power quality conditioner (UPQC), suppressing the load harmonic currents and compensating reactive power. Additionally, regulated, balanced and harmonic free output voltages are provided to the load. Since the PV-UPQC is based on a dual compensation strategy, the series converter operates as a sinusoidal current source, whereas the parallel converter operates as a sinusoidal voltage source. Thus, seamless transition can be achieved from the interconnected to the islanding operation modes, and vice-versa, without load voltage transients. Moreover, to overcome problems associated with sudden solar irradiation changes, fast power balance involving the PV array and the grid is obtained, since the feed-forward control loop acts on the generation of the series inverter current references. As a result, the dynamic responses of both inverter currents and dc-bus voltage are improved. Detailed analysis involving the active power flow through the inverters is performed allowing proper understanding of the PV-UPQC operation, as well as assisting to design of the power converters. Simulation and experimental results are presented to evaluate both dynamic and static performances of the PV-UPQC tied to the electrical distribution system.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Campanhol.pdf (10.93 Mbytes)
Date de Publication
2017-12-20
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.