• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Mémoire de Maîtrise
DOI
https://doi.org/10.11606/D.18.2009.tde-04012010-101611
Document
Auteur
Nom complet
Etienne Biasotto
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Carlos, 2009
Directeur
Jury
Oleskovicz, Mário (Président)
Ahn, Se Un
Vieira Júnior, José Carlos de Melo
Titre en portugais
Um procedimento de análise para a repotenciação de linhas de subtransmissão de 34,5 KV para 69 KV
Mots-clés en portugais
5 kV
ATP
ATPDraw e FLUX®
Classe de 34
Classe de 69 kV
Elevação da classe de tensão
Linhas de subtransmissão
Procedimento de análise
Repotenciação
Resumé en portugais
Como parte de um projeto de pesquisa e desenvolvimento (P&D) mais amplo, que está sendo desenvolvido pela Escola de Engenharia de São Carlos - USP e Companhia Paulista de Força Luz (CPFL), com previsão de conclusão para 2010, este trabalho tem por objetivo apresentar os principais procedimentos para a realização da repotenciação de linhas de subtransmissão de 34,5 KV para 69 KV. Para atingir esse objetivo, é realizada inicialmente uma apreciação do estágio atual dos estudos sobre o tema, abordando inclusive outros métodos além daquele que será objeto específico desse estudo. Em seguida, discutem-se tópicos relevantes dos métodos apresentados de forma que, esse estudo, além de cumprir o já mencionado objetivo específico de apresentar soluções para aumentar a capacidade de transmissão de uma determinada linha, mantendo a sua faixa de servidão, indicará parâmetros válidos para a realização de outros projetos da mesma natureza. Sequencialmente são apresentadas as etapas desenvolvidas para a operacionalização da repotenciação de uma linha, a começar pela escolha da mais adequada, a seleção do método a ser utilizado, levando-se em consideração tanto a alteração do limite térmico da linha quanto à elevação de sua tensão operativa e os aspectos ambientais que envolvem a repotenciação. Finalmente, fazendo uso dos softwares ATP, através da interface gráfica ATPDraw (empregado para as XIV simulações de transitórios eletromagnéticos) e do Flux®, para as simulações dos campos elétricos em torno dos isoladores, realizou-se um conjunto de simulações computacionais pertinentes para um bom conhecimento do funcionamento da linha de subtransmissão a ser repotenciada na classe de interesse. Todas as etapas e as conclusões preliminares sobre o assunto delineado serão apresentadas neste documento.
Titre en anglais
A procedure of analysis for repowering subtransmission lines from 34.5 KV to 69 KV
Mots-clés en anglais
Analysis procedure
ATP
ATPDraw e FLUX®
Class 34.5 kV
Class 69 kV
Raising the voltage class
Repowering
Subtransmission lines
Resumé en anglais
As part of a wider research and development project, which is being developed between Escola de Engenharia de São Paulo USP and Companhia Paulista de Força e Luz (CPFL), scheduled to be finished in 2010, this work aims to present the main procedures to perform a repowering on subtransmission lines from 34.5 KV to 69 KV. To achieve this purpose, an assessment of the current studies about the subject is carried out, including an approach of other methods besides the one which is going to be the specific object of this study. After this, relevant points about the main methods are discussed in such a way that this study, in addition to serve its specific purpose, that is to present solutions in order to increase the transmission capacity of a determined line, keeping its right-of-way, can also point out valuable parameters which can be used to develop other projects of similar nature. Sequentially, the steps followed to operationalize the line repowering are presented, starting with the choice of the most suitable line, the selection of the method to be used, and taking into consideration both the change in the line thermal limit and the elevation on its operating voltage and also the environmental aspects involving repowering. At last, making use of ATP software throughout ATPDraw graphical interface (which is used to simulate electromagnetic transients) and Flux®, that simulates electrical fields around insulators, it is carried out a set of computational XVI simulations which are relevant to a good knowledge of the line subtransmission running. All the steps and preliminary conclusions about the subject are going to be outlined on this document.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Etienne.pdf (5.87 Mbytes)
Date de Publication
2010-01-25
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.