Thèse de Doctorat
DOI
https://doi.org/10.11606/T.18.2013.tde-04092013-105844
Document
Auteur
Nom complet
Hermes Manoel Galvão Castelo Branco
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Carlos, 2013
Directeur
Jury
Oleskovicz, Mário (Président)
Coelho, Jorge
Delbem, Alexandre Cláudio Botazzo
Duque, Carlos Augusto
Souza, Benemar Alencar de
Titre en portugais
Modelagem multiobjetivo para o problema da alocação de monitores de qualidade da energia em sistemas de distribuição de energia elétrica
Mots-clés en portugais
Algoritmos evolutivos multiobjetivo
Alocação de monitores
Otimização multiobjetivo
Qualidade da energia elétrica
Sistemas de distribuição
Sistemas elétricos de potência
Resumé en portugais
Problemas ocasionados por perturbações na qualidade da energia elétrica (QEE) podem provocar sérios prejuízos, tanto de cunho social, quanto financeiros, aos clientes conectados ao sistema elétrico de potência como um todo. Neste contexto, os clientes que mais sofrem são os clientes industriais, pois estes possuem cargas sensíveis a vários distúrbios associados à falta da QEE. Sendo assim, para adoções de medidas preventivas, ou corretivas, que melhorem os índices de QEE, faz-se necessário um monitoramento dos sistemas elétricos que permita um melhor acompanhamento da ocorrência dos distúrbios. Nesta pesquisa é proposta a modelagem do problema de alocação ótima de monitores de QEE em sistemas de distribuição com múltiplos objetivos, os quais são: minimização do custo do monitoramento, minimização da ambiguidade topológica, maximização do monitoramento das cargas, maximização da quantidade de ramais monitorados, minimização da quantidade de afundamentos não monitorados, e maximização da redundância do monitoramento dos afundamentos. Na resolução do problema foi utilizado o Algoritmo Evolutivo Multiobjetivo com Tabelas (AEMT), adotado por ter boa capacidade de resolução com muitos objetivos. Os resultados obtidos permitiram observar que o AEMT forneceu as fronteiras de Pareto com soluções diversificadas e bem distribuídas ao longo da mesma, mostrando-se de grande relevância para o planejamento de sistemas de monitoramento da QEE em sistemas de distribuição de energia. A principal contribuição desta tese é o fornecimento de um modelo que permite às empresas de energia avaliar os investimentos que farão nos seus sistemas de monitoramento considerando seis critérios distintos, permitindo uma maior flexibilidade no estabelecimento do plano de monitoramento e uma melhor análise do custo/benefício considerando os seis aspectos abordados.
Titre en anglais
Multiobjective modeling for the problem of allocation of power quality monitors in electrical distribution system
Mots-clés en anglais
Allocation monitors
Distribution systems
Electrical power distribution systems
Multiobjective evolutionary algorithms
Multiobjective optimization
Power quality
Resumé en anglais
Problems arising from disturbances in power quality (PQ) can cause serious damage, both social, and financial, to customers connected to the electrical power distribution systems as a whole. In this context, the customers who suer most are industrial customers, as they have loads sensitive to various disturbances associated with the lack of PQ. Thus, in order to adopt preventive or corrective measures to improve PQ rates, it is necessary to monitor electrical systems to allow better oversight of the occurrence of disturbances. In this research, the proposal is to model the problem of optimal allocation of power quality monitors in distribution systems with multiple objectives. The multiple objectives are: minimizing the monitoring cost, minimizing ambiguities in topology, maximizing the load monitoring, maximizing the area monitoring, minimizing the voltage sag unmonitored, and maximizing the redundancy in the sag monitoring. In solving the problem, a Multiobjective Evolutionary Algorithm with Tables (MEAT) was adopted due to ability to deal with many objectives. The results show that the AMET finds a set of ecient solutions that are diversified and well-distributed along the Pareto Front, and that they are highly relevant for planning of PQ monitoring systems in electrical power distribution systems. The main contribution of this thesis is to provide a model that allows utilities better evaluate investments that they will make in their monitoring systems comprising six dierent criteria, allowing greater flexibility in establishing the monitoring plan and a better analysis of cost/benefit considering the six aspects.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Hermes.pdf (5.15 Mbytes)
Date de Publication
2013-09-06
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.