Mémoire de Maîtrise
DOI
https://doi.org/10.11606/D.18.2009.tde-16112009-164527
Document
Auteur
Nom complet
Antonio Carlos Leal de Castro Junior
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Carlos, 2009
Directeur
Jury
Bretas, Newton Geraldo (Président)
Alberto, Luís Fernando Costa
Silva, Luiz Carlos Pereira da
Titre en portugais
Estudo de controle preventivo para análise do colapso de tensão
Mots-clés en portugais
Colapso de tensão
Estabilidade de tensão
Fluxo de carga continuado
Sistemas elétricos de potência
Resumé en portugais
Até meados da década de setenta a atenção dos técnicos do setor elétrico estava voltada aos problemas advindos da chamada instabilidade de ângulo, onde perturbações mais severas, tais como curtos-circuitos, levam os sistemas a perderem estabilidade. À medida que os sistemas foram ficando mais sobrecarregados, algumas não linearidades tornaram-se mais evidentes e problemas que até então não eram observados passaram a ocorrer. Um desses problemas que passou a despertar maior atenção dos engenheiros de potência foi justamente o problema de colapso de tensão. Tal fenômeno está relacionado à incapacidade do sistema elétrico de prover o balanço entre a potência gerada e a requisitada pelas cargas, devido, principalmente, à limitada capacidade de transmissão, ou ainda, devido a um suporte de potência reativa local inadequada. Neste trabalho pretende-se avaliar o grau de impacto que uma contingência ou uma ação de controle teria sobre um sistema de potência. Para avaliar este grau de impacto pretende-se utilizar os conceitos de coerência de cargas, a partir da matriz de impedância nodal, determinando-se quais barras seriam mais influenciadas por uma certa perturbação no sistema. Quando este número de barras é elevado, indica que a contingência deveria ser classificada como mais grave do que uma contingência com margem baixa, porém de impacto local e de fácil solução. Durante o funcionamento do sistema podem ocorrer eventos que afetam as características de tensão e freqüência, causando inclusive a interrupção do fornecimento de energia. Portanto, o engenheiro de operação deve dispor de ferramentas que controlem e que permitam prever esta situação de risco e tomar medidas para evitá-las. Assim, é de extrema importância, a análise de estabilidade do sistema, a fim de em um futuro próximo, prevenir distúrbios no seu funcionamento normal.
Titre en anglais
Study of preventive control for the analysis of voltage collapse
Mots-clés en anglais
Electrical power systems
Load flow continued
Preventive control
Voltage collapse
Voltage stability
Resumé en anglais
Until the middle of the seventies the attention of the technicians of the electricity sector was focused on the problems arising from instability of the callangle, where the most severe, such as short circuits, take the systems to lose stability. As the systems were getting overloaded, some nonlinearities have become more evident and problems that were not seen until then began to occur. One such problem that has awaken the attention of power engineers was precisely the problem of voltage collapse. This phenomenon is related to the inability of the electric system to provide the balance between power generated and required by the loads, mainly due to the limited transmission capacity, or because a local reactive power support inadequate. This work aims to assess the degree of impact that a contingency or an action of control would have on a system of power. To assess the degree of impact is intended to use the concepts of consistency of loads from the nodal impedance matrix, it was determined that bars would be more influenced by a disturbance in the system. When this number of bars is high, indicates that the contingency should be classified as more serious than a contingency margin with low, but the local impact and easy solution. During operation of system events may occur that affect the characteristics of voltage and frequency, causing even the interruption of power supply. Therefore, the operating engineer should have the tools to monitor and to predict that this situation of risk and take steps to avoid them. It is therefore of extreme importance, the analysis of system stability, so that in the near future, to prevent disturbances in their normal operation.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Antonio.pdf (1.02 Mbytes)
Date de Publication
2009-11-24
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.