• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Master's Dissertation
DOI
https://doi.org/10.11606/D.23.2015.tde-15042015-121900
Document
Author
Full name
Sandra Ribeiro de Barros da Cunha
E-mail
Institute/School/College
Knowledge Area
Date of Defense
Published
São Paulo, 2015
Supervisor
Committee
Aranha, Ana Cecilia Corrêa (President)
Luiz, Ana Cláudia
Silva, Alan Roger dos Santos
Title in Portuguese
Efeito de três diferentes doses de radiação com raios-X na microdureza, morfologia superficial, espectrometria de energia dispersiva de radios-X (EDS) e resistência de união ao esmalte e dentina com dois diferentes sistemas adesivos
Keywords in Portuguese
Adesivo universal
Dentina
EDS
Esmalte
MEV
Microcisalhamento
Microdureza
Radiação ionizante
Radioterapia
Resistência de união
Abstract in Portuguese
Este estudo teve como objetivo analisar dentina e esmalte irradiados com diferentes doses de radiação ionizante com raios-x (20, 40 e 70Gy), através da microdureza, morfologia superficial, conteúdo mineral e resistência de união com adesivo de condicionamento total de 2 etapas (Adper Single Bond 2) e um novo sistema adesivo, universal, com a técnica auto-condicionante (Universal Single Bond). Oitenta e quatro terceiros molares humanos foram cortados, separados e preparados para cada ensaio. Para os ensaios de microdureza e microcisalhamento as amostras foram incluídas em resina acrílica e polidas. Para a microscopia eletrônica de varredura (MEV) e espectrometria de energia dispersiva de raios-x (EDS), as amostras foram fixadas em solução de glutaraldeído 3%, lavadas em solução de cacodilato 0,1M e desidratadas em álcool etílico crescente. A microdureza (n=30) foi realizada pré e pós-radioterapia, com força de 50gf em esmalte cervical, médio e oclusal e 25gf em dentina profunda, média e rasa, por 30s. As amostras para o microcisalhamento foram divididas em 4 grupos (n=20) e 2 subgrupos (n=10) conforme o sistema adesivo. Foram construídos 3 corpos de prova cilíndricos com 1mm de diâmetro e altura em cada amostra. O teste de microcisalhamento foi realizado em máquina de ensaio universal com velocidade de 1mm/min. Os resultados indicam perda de propriedade de microdureza apenas em esmalte cervical em todas as três doses (20Gy pré-radioterapia: 298,04±11,80 e pós-radioterapia: 294,36±16,68; 40Gy pré-radioterapia: 285±19,45 e pósradioterapia: 275,3±36; 70Gy pré-radioterapia: 291,98±16,51 e pós-radioterapia: 283,68 ± 21,64) e em dentina em todas as profundidades (profunda: 20Gy préradioterapia: 57,79±1,96; pós-radioterapia: 55,37±1,30; 40Gy pré-radioterapia: 57,31±1,76; pós-radioterapia: 55,83±1,63; 70Gy não apresentou alterações; média: 20Gy pré-radioterapia: 58,05±1,79; pós-radioterapia: 55,36±1,20; 40Gy préradioterapia: 57,87± 2,04; pós-radioterapia: 55,65 ± 2,48; 70Gy não apresentou alterações; rasa: 20Gy pré-radioterapia: 56,60±12,17; pós-radioterapia: 55,18±2,57; 40Gy pré-radioterapia: 57,36±2,78; pós-radioterapia: 55,18± 2,57; 70Gy préradioterapia: 55,08±1,94; pós-radioterapia: 54,72±2,57). O teste de microcisalhamento não apresentou diferença significativa entre grupo controle e as 3 doses, tanto para esmalte (p=0,325) como para dentina (p=0,719), apresentando o adesivo Universal Single Bond, em dentina, a resistência de união mais satisfatória. A análise de padrão de fratura para dentina, indicou um maior número de rupturas coesivas em dentina na dose 70Gy quando comparada ao grupo controle. Em esmalte prevaleceram as fraturas do tipo adesivas. As eletromicrografias apresentaram alterações apenas em esmalte na dose 70Gy, com prismas de esmalte mais curtos e arredondados. O EDS mostrou que o conteúdo mineral permaneceu intacto em ambos substratos. Dentro das limitações de um estudo in vitro, conclui-se que a radiação ionizante apresenta maior interação preferencialmente em dentina, no entanto, o EDS mostra não haver modificação no conteúdo mineral em ambos substratos. Existe uma diminuição da microdureza em dentina, porém as alterações não são suficientes para interferir na resistência de união dos substratos irradiados, que mostraram resultados mais satisfatórios com o sistemas adesivos universal, utilizando-se a técnica auto-condicionante.
Title in English
The effect of three different doses of radiation with x-rays in the microhardness, superficial morfology, energy dispersive X-ray spectroscopy (EDS) and bond strength of enamel and dentin with two adhesive systems
Keywords in English
Bonding
Dentin
EDS
Enamel
Ionizing radiation
Microhardness
Microshear-bond
Radiotherapy
SEM
Universal adhesive
Abstract in English
The aim of this study was to evaluate the effects of different doses (20Gy, 40Gy and 70Gy) of ionizing radiation with x-rays in the microhardness, superficial morphology, mineral content and bonding effectiveness with a 2 steps all-etch adhesive (Adper Single Bond 2) and the new generation of adhesive, the universal adhesive system, (Universal Single Bond), using the self-etch technique. Eighty-four third molars were cutted, separed and prepared for each assay. For the microshear-bond and microhardness the samples were included in acrylic resin and then polished. For the scanning electron miscroscopy (SEM) and energy dispersive x-ray spectroscopy (EDS), the samples were fixated in a 3% glutaraldehyde solution, washed in 0,1M cacodylate solution and dehydrated in increscent concentrations of ethyl alcohol. The microhardness (n=30) was held pre and post radiotherapy with 50gf on cervical, middle and occlusal enamel and 25kg on superficial, middle and deep dentin, both cases with 30s. The microshear-bond was divided in 4 groups (n=20) and 2 subgroups (n=10) according to the adhesive system. Three cylinders were built with 1mm in diameter and heigh in every sample. The assay were accomplished at an universal testing machine with 1mm/min. Results indicate loss of microhardness properties only in cervical enamel at all 3 doses (20Gy pre-radiotheraphy: 298,04 ± 11,80 and post-radiotherapy: 294,36 ± 16,68; 40Gy pre-radiotherapy: 285 ± 19,45 and post-radiotherapy: 275,3 ± 36; 70Gy pre-radiotherapy: 291,98 ± 16,51 and post-radiotherapy: 283,68 ± 21,64) and in all dentin depths (deep: 20Gy preradiotherapy: 57,79 ± 1,96; post-radiotherapy: 55,37 ± 1,30; 40Gy pre-radiotherapy: 57,31 ± 1,76; post-radiotherapy: 55,83 ± 1,63; 70Gy showed no alteration; Middle: 20Gy pre-radiotherapy: 58,05 ± 1,79; post-radiotherapy: 55,36 ± 1,20; 40Gy preradiotherapy: 57,87 ± 2,04; post-radiothetrapy: 55,65 ± 2,48; 70Gy showed no alteration; Superficial: 20Gy pre-radioterapia: 56,60 ± 12,17; post-radiotrapia: 55,18 ± 2,57; 40Gy pre-radiotherapy: 57,36 ± 2,78; post-radiotherapy: 55,18 ± 2,57; 70Gy pre-radiotherapy: 55,08 ± 1,94; post-radiotherapy: 54,72 ± 2,57). The microshearbond test did not show significant difference between the control group and the 3 doses, both enamel (p=0.325) and dentin (p=0.719), showing better bonding with Universal Single Bond adhesive in dentin. The fracture pattern analysis indicated a larger number of cohesive failure in dentine with the 70Gy dose when compared with control group. The micrographs showed changes only on enamel at 70Gy dose, with shorter and rounder prisms. EDS test indicated no changes in mineral content for both substrates. Knowing the limitations of an in vitro study, it were concluded that ionizing radiation shows deleterious effects preferentially in dentin, probably due to it's high organic content, since EDS showed no modifications both enamel and dentin. There is a reduction in microhardness on dentin, but the changes are not enough to interfere at bonding properties of irradiated substrates, showing better results when used the universal adhesive with the self-etch techniques.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
Publishing Date
2015-05-06
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.