• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Disertación de Maestría
DOI
https://doi.org/10.11606/D.23.2005.tde-14102005-193239
Documento
Autor
Nombre completo
Marcelo Gomes da Silva
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Paulo, 2005
Director
Tribunal
Mori, Matsuyoshi (Presidente)
Sendyk, Claudio Luiz
Vasconcellos, Adalberto Bastos de
Título en portugués
"Influência da esplintagem de restaurações protéticas fixas e do número de implantes na distribuição de tensões em mandíbula edentada posterior - análise em elementos finitos"
Palabras clave en portugués
análise de elemento finito
implantes dentários
Prótese parcial fixa
tensões
Resumen en portugués
Em casos de edentulismo parcial, especialmente na ausência de três ou mais dentes posteriores contíguos, não há consenso sobre o número ideal de implantes a serem utilizados nem sobre a conveniência biomecânica de unir ou não as coroas protéticas. O presente estudo teve como finalidade analisar a influência da esplintagem de restaurações protéticas fixas e do número de implantes na distribuição das tensões de von Mises em modelos matemáticos bidimensionais obtidos pelo método de elementos finitos. A partir da imagem digitalizada de uma peça anatômica real, correspondente ao corte sagital da porção posterior esquerda de uma mandíbula, três modelos foram desenvolvidos com as seguintes configurações: (1) coroas protéticas isoladas sobre três implantes; (2) coroas protéticas esplintadas sobre três implantes; e (3) prótese parcial fixa sobre dois implantes, com um pôntico intermediário. Uma carga estática de 300N foi dividida, com igual magnitude, por 15 áreas de aplicação nas superfícies oclusais e angulada em 15º em relação ao longo eixo das restaurações. Os resultados mostraram que o modelo com coroas esplintadas sobre três implantes apresentou os menores valores de tensão, enquanto os maiores valores de tensão foram encontrados no modelo com coroas isoladas. O limite de proporcionalidade dos materiais e estruturas analisadas não foi alcançado nos três modelos, fato que não contra-indicou nenhuma das configurações estudadas. Entretanto, os resultados sugeriram que o planejamento do tratamento deve ser adequado a condições anatômicas, oclusais e biomecânicas específicas.
Título en inglés
Influence of the splinting of fixed prosthetic restorations and the number of implants on stress distribution in posterior edentulous mandible – finite element analysis
Palabras clave en inglés
dental implants
finite element analysis
Fixed partial denture
stress
Resumen en inglés
In cases of partial edentulism, specially in the absence of three or more contiguous posterior teeth, there is not a consensus about the ideal number of implants nor the biomechanical convenience of splinting or not prosthetic crowns. The aim of the present study was to analyze the influence of the splinting of fixed prosthetic restorations and the number of implants on von Mises stress distribution within mathematical two-dimensional models obtained from finite element method. From the digitalized image of a real anatomical piece, corresponding to the sagital slice of the left posterior portion of a mandible, three models were constructed in the following configurations: (1) non-splinted prosthetic crowns on three implants; (2) splinted prosthetic crowns on three implants; and (3) fixed partial denture on two implants, with an intermediate pontic. A 300N static load was divided, in equal magnitude, by 15 application areas on occlusal surfaces and angled in 15º in relation to the long axis of the restorations. The results showed that the model with splinted crowns on three implants presented the lowest stress values, whereas the highest stress values were found in the model with non-splinted crowns. The proportional limit of the analyzed materials and structures was not reached in the three models, fact that did not contraindicate any studied configuration. However, the results suggested that treatment planning may be adequate to anatomical, occlusal and biomechanical specific conditions.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2005-10-27
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.