• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Mémoire de Maîtrise
DOI
https://doi.org/10.11606/D.23.2020.tde-30082021-101720
Document
Auteur
Nom complet
Teresa Cristina Alves da Silva Gonzalez de Carvalho
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Paulo, 2020
Directeur
Jury
Chilvarquer, Israel (Président)
Beaini, Thiago Leite
Hayek, Jorge Elie
Pereira, Marlene Fenyo Soeiro de Matos
Titre en portugais
Comparação da eficácia do método de análise de modelos realizados de forma digital e convencional
Mots-clés en portugais
Análise de modelos
Análise digital
Escaneamento intraoral
Software
Resumé en portugais
Os escâneres intraorais estão trazendo uma maior praticidade ao cirurgião dentista nos consultórios odontológicos em substituição, ainda que parcial das moldagens convencionais; e para as clínicas de radiodiagnóstico uma otimização de tempo na confecção dos modelos ortodônticos de estudo, para as análises de modelos feitas via software, além de trazer maior conforto e comodidade ao paciente. Este estudo teve como objetivo comparar análises de modelos feitas de forma convencional (manual) e digital. A metodologia aplicada baseia-se em quarenta e cinco pacientes entre 12 e 25 anos, com dentição permanente completa, classe I ou II de Angle que foram submetidos a moldagem convencional para obtenção de modelos de estudo de gesso e também foram escaneados por um único examinador com o escâner CS3600 da Carestreamâ, para obtenção de modelo digital. As medidas manuais de uma análise longitudinal e uma transversal foram feitas por três cirurgiões-dentistas, previamente padronizados pelos critérios de execução do método, com o auxílio de um paquímetro digital. Após intervalo de quinze dias, todas mensurações manuais foram repetidas e executadas com o software CS Model+â Carestream, comparou-se todas as medidas. Resultados: o índice de confiabilidade do software comparado aos cirurgiões dentistas foi excelente (CCI > 0,89), quando os modelos digitais não possuíam braquetes, e de replicabilidade média boa (CCI >79) quando possuíam aparato ortodôntico, onde concluímos que o software em questão apesar de bom, e de grande auxílio para a odontologia, em especial as clínicas de radiodiagnóstico e ortodontistas, ainda possui limitações que precisam ser corrigidas na prática diária.
Titre en anglais
Comparison of the effectiveness of the analysis of orthodontic models performed manually and digitally
Mots-clés en anglais
Digital analysis
Intraoral scanning
Model analysis
Software
Resumé en anglais
Intraoral scanners are bringing greater practicality to the dentist in dental offices to replace, although partial of conventional moldings; and for radio diagnostic clinics an optimization of time in the production of orthodontic models of study, for the analysis of models made via software, and bring greater comfort and convenience to the patient. This study aimed to compare conventional (manual) and digital model analysis. The applied methodology is based on forty-five patients between 12 and 25 years old, with complete permanent dentition, Angle class I or II who underwent conventional molding to obtain plaster study models and were also scanned by a single examiner with the Carestreamâ CS3600 scanner to obtain a digital model. The manual measurements of a longitudinal and a transversal analysis were made by three previously trained dentists to perform analysis of orthodontic models, with the aid of a digital caliper, and all the measurements obtained were compared with those of a software CS Model+, Carestreamâ. Results: the software reliability index compared to dental surgeons was excellent (ICC > 0.89), when digital models did not have brackets, and of good average replicability (ICC >79) when they had orthodontic appliances, where we concluded that the software in question, although good, and of great help for dentistry, especially radiodiagnosis and orthodontist clinics, it still has limitations that need to be corrected in daily pratice.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Date de Publication
2021-09-24
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.