• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Master's Dissertation
DOI
https://doi.org/10.11606/D.23.2016.tde-30092016-163902
Document
Author
Full name
Stephanie Soares Favero
E-mail
Institute/School/College
Knowledge Area
Date of Defense
Published
São Paulo, 2016
Supervisor
Committee
Cesar, Paulo Francisco (President)
Genova, Luís Antonio
Sesma, Newton
Title in Portuguese
Efeito do material no comportamento mecânico de laminados cerâmicos ultrafinos
Keywords in Portuguese
CAD-CAM
Cerâmicas odontológicas
Ciclagem mecânica
Dissilicato de lítio
Laminados ultrafinos
Porcelana
Abstract in Portuguese
Objetivos: (1) determinar a carga de fratura e o modo de falha de laminados cerâmicos ultrafinos processados via CAD-CAM em função da microestrutura do material (vitrocerâmica à base de dissilicato de lítio ou porcelana à base de leucita); (2) desenvolver metodologia de ciclagem mecânica para determinar o tempo de vida e o modo de falha de laminados cerâmicos ultrafinos processados via CADCAM. Materiais e métodos: dezesseis dentes humanos, incisivos centrais superiores, foram utilizados para confecção dos espécimes. Os dentes sofreram mínimo preparo, em esmalte, para adequada adaptação dos laminados cerâmicos ultrafinos. Os laminados de dissilicato de lítio e de porcelana foram confeccionados via CAD-CAM e cimentados com cimento resinoso sobre os dentes. Quatro espécimes de cada grupo foram levados à máquina de ensaios universal para determinação da carga de fratura dos laminados. Para o desenvolvimento de metodologia para determinação do tempo de vida dos laminados, uma série de testes piloto foi realizada, utilizando-se diferentes parâmetros como: tipo de antagonista (dentes naturais ou roletes metálicos), carga aplicada (20, 30 ou 40 N) e esquema de ciclo mastigatório (incisão ou deslizamento). Os padrões de falha dos laminados foram analisados em um estereomicroscópio, e os resultados obtidos no ensaio de carga de fratura foram analisados por ANOVA e teste de Tukey. Resultados: o valor médio obtido de carga de fratura para o dissilicato de lítio foi de 431,8 ± 217,9 N, enquanto que para a porcelana foi de 454,4 ± 72,1 N. Não houve diferença estatística entre os valores de carga de fratura encontrados, porém, o desvio padrão e o coeficiente de variação da vitrocerâmica foram muito superiores em relação aos da porcelana. Houve diferença no modo de falha dos materiais testados, sendo que a porcelana apresentou um maior número de falha por lascamento e o dissilicato de lítio apresentou maior quantidade de falha da estrutura dental. Na ciclagem mecânica, para cada condição testada, uma resposta diferente foi obtida. No tipo de ciclo incisão, os antagonistas (dente natural) fraturaram quando as cargas de 30 N e 40 N foram aplicadas. No tipo de ciclo deslizamento, o antagonista (dente natural) sofreu desgaste da borda incisal com carga de 30 N. Para o antagonista rolete metálico, quando a carga de 30 N foi aplicada ocorreu fratura do laminado, e quando aplicada a carga de 20 N, houve desgaste excessivo do rolete metálico. Conclusão: (1) o material utilizado não afetou a carga de fratura dos laminados cerâmicos ultrafinos quando o teste estático foi utilizado. Entretanto, o modo de falha foi significativamente diferente, sendo que a porcelana sofreu mais lascamentos do que o dissilicato de lítio; o qual, por sua vez, apresentou a maioria das falhas relacionadas à estrutura dental. (2) Não foi possível determinar uma combinação de parâmetros de ciclagem mecânica que permitisse a determinação dos parâmetros de fadiga para laminados cerâmicos ultrafinos, já que o número máximo de ciclos alcançados foi de 536.818 ciclos. Dessa forma, estudos futuros precisam ser realizados para que uma metodologia apropriada permita determinar parâmetros de fadiga clinicamente relevantes para laminados cerâmicos ultrafinos em dentes anteriores.
Title in English
The effect of the material on the mechanical behaviour of the ultrathin ceramic laminates
Keywords in English
CAD-CAM, Lithium disilicate
Dental ceramics
Mechanical cycling
Porcelain
Ultrathin laminate
Abstract in English
Objectives: (1) to determine the fracture load and the failure mode of the ultra-thin ceramic laminates processed via CAD-CAM according to the microstructure of the material (lithium disilicate-based glass-ceramic or leucite-based porcelain); (2) to develop a fatigue methodology capable of determining the lifetime of ultra-thin ceramic laminates processed via CAD-CAM. Materials and methods: sixteen human maxillary central incisors were used to produce the specimens. The teeth required minimal preparation on the enamel for proper adaptation of the ultra-thin ceramic laminates. Ceramic laminates made of lithium disilicate and feldspathic porcelain with thicknesses between 0.3 mm to 0.5 mm were produced via CAD-CAM and cemented with resin cement. Four specimens of each group were taken to a universal testing machine to determine the fracture load of the laminates. For the development of a fatigue methodology, a series of pilot tests was performed using different parameters such as: type of antagonist (natural teeth or metal roller), applied load (20, 30 or 40 N), and type of masticatory cycle (incision or sliding). Failure modes were analysed using a stereomicroscope. Fracture load data were analysed by ANOVA and Tukey's test. Results: the mean fracture load obtained for the glass-ceramic was 431.8 ± 217.9 N, while that obtained for the porcelain was 454.4 ± 72.1 N. There was no statistical difference between the mean fracture load values; however, the standard deviation and the coefficient of the variation of the glass-ceramic were both higher than those obtained for the porcelain. There was also a difference in the failure modes for the two materials tested. The porcelain showed a higher number of factures due to chipping and the lithium disilicate showed a higher number of tooth structure failure. The fatigue experiment showed different results depending on the condition analysed. In the incision cycle, the antagonists (natural tooth) fractured when loads of 30 N and 40 N were applied. In the slide type of cycle, the antagonist (natural tooth) suffered wear on the incisal edge after applying 30 N of load. For the metal roller antagonist, when a 30 N load was applied, the ceramic laminate fractured, and when a 20 N load was applied, an excessive wear of the metal roller occurred. Conclusion: (1) The material used did not affect the fracture load of ultra-thin ceramic laminates when the static test was used. However, the failure mode was significantly different, as porcelain suffered more chipping than the lithium disilicate; which, in turn, showed most fails related to the tooth structure. (2) It was not possible to determine the combination of the mechanical cycling parameters that would allow the determination of fatigue parameters for ultra-thin ceramic laminates, since the maximum number of cycles reached was 536,818 cycles. In this way, future studies need to be carried out so that a clinically relevant methodology can be developed to determine the fatigue parameters of ultra-thin ceramic laminates in the anterior teeth.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
Publishing Date
2016-10-18
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.