• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Tesis Doctoral
DOI
https://doi.org/10.11606/T.23.2019.tde-08042019-161249
Documento
Autor
Nombre completo
Vítor Marques Sapata
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Paulo, 2018
Director
Tribunal
César Neto, João Batista (Presidente)
Januário, Alessandro Lourenço
Romito, Giuseppe Alexandre
Shibli, Jamil Awad
Título en portugués
Mudanças profilométricas de tecidos peri-implantares durante 5 anos: um estudo comparando sistemas de implantes de um e dois estágios
Palabras clave en portugués
Análise profilométrica
Coroa
Implantes dentários
Prótese
Prótese fixa
Seres humanos
Tecido mole
Resumen en portugués
Avaliar as alterações profilométricas dos tecidos moles vestibulares entre o exame inicial e os 5 anos de acompanhamento, utilizando sistemas de implantes dentários de um e dois estágios. Sessenta pacientes receberam aleatoriamente implantes dentários de dois estágios (BRA) ou de estágio único (STM). Os modelos foram obtidos no início do estudo (após a inserção da coroa), no primeiro ano e no quinto ano de acompanhamento. Os arquivos de estereolitografia foram obtidos dos modelos para superposição digital. Um implante e o dente natural contralateral foram selecionados para a análise. Trinta e três pacientes (BRA = 16; STM = 17) foram incluídos. As medidas incluíram mudanças para altura da coroa (CH) e espessura estimada do tecido mole, bem como a mudança profilométrica no implante e no local do dente. Métodos não paramétricos foram aplicados para as análises estatísticas, medianas e quartis foram apresentados. O grupo BRA perdeu -0,39 mm e o grupo STM perdeu -0,40 mm de volume entre o início e o acompanhamento de 5 anos no local do implante (p> 0,05). O local do dente perdeu -0,18 mm (BRA) e -0,12 mm (STM) (p> 0,05). As diferenças de volume entre implantes e dentes foram de -0,05 mm (inicial a 1 ano) e -0,25 mm (inicial a 5 anos) para BRA, enquanto para STM, os valores foram de 0,03 mm (inicial a 1 ano) e -0,16 mm (inicial a 5 anos). As mudanças para CH em 1 e 5 anos de acompanhamento foram de 0,10 e 0,09 mm (BRA) e 0,03 e 0,22 mm para STM. As mudanças na espessura do tecido em 1 e 5 anos no grupo BRA foram de -0,28 e -0,66 mm a 1 mm, -0,21 e -0,46 mm a 3 mm e -0,32 e -0,45 mm a 5 mm, respectivamente. As mudanças no grupo STM foram de -0,15 e -0,54 mm a 1 mm, -0,24 e -0,48 mm a 3 mm e -0,32 e -0,57 mm a 5 mm, respectivamente. Nenhuma mediana significativamente diferente foi observada. Alterações mínimas, lineares e profilométricas, ocorreram nos locais dos implantes entre o exame inicial e os 5 anos, entre os locais do implante e do dente e entre os dois sistemas de implantes.
Título en inglés
Profilometric changes of peri-implant tissues over 5 years: a study comparing a one- and two-piece implant system
Palabras clave en inglés
Crown
Dental implants
Denture
Fixed
Humans
Profilometric analysis
Soft tissue
Resumen en inglés
To assess the profilometric changes of the buccal soft tissues between baseline and 5 years of loading using a one- and two-piece dental implant system. Sixty patients randomly received dental implants of either a two-piece type (BRA) or a one-piece type (STM). Casts were obtained at baseline (after crown insertion), at the 1-year and at the 5-year followup. Stereolithography files were obtained from the casts for digital superimposition. One implant and the contralateral natural tooth were selected for the analysis. Thirty-three patients (BRA = 16; STM = 17) were included. Measurements included changes for crown height (CH) and estimated soft tissue thickness, as well as the profilometric change at the implant and the tooth site. Nonparametric methods were applied for the statistical analyses and medians and quartiles presented. The BRA group lost -0.39 mm and the STM group lost -0.40 mm of volume between baseline and the 5-year follow-up at the implant site (p > 0.05). The tooth site lost -0.18 mm (BRA) and -0.12 mm (STM) (p > 0.05). Volume differences between implants and teeth amounted to -0.05 mm (baseline to 1 year) and -0.25 mm (baseline to 5 years) for BRA, while for STM, the values were 0.03 mm (baseline to 1 year) and -0.16 mm (baseline to 5 years). The changes for implant CH at 1 and 5 years of follow-up amounted 0.10 and 0.09 mm (BRA) and to 0.03 and 0.22 mm (STM). The changes in tissue thickness at 1 and 5 years in the BRA group amounted to -0.28 and -0.66 mm at 1 mm, -0.21 and -0.46 mm at 3 mm, and -0.32 and -0.45 mm at 5 mm, respectively. The changes in the STM group amounted to -0.15 and -0.54 mm at 1 mm, -0.24 and -0.48 mm at 3 mm, and -0.32 and -0.57 mm at 5 mm, respectively. No significantly different medians were observed. Minimal profilometric and linear changes occurred at implant sites between baseline and 5 years, between implant and tooth sites and between the two implant systems.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2019-06-04
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.