• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Tesis Doctoral
DOI
https://doi.org/10.11606/T.23.2010.tde-22122010-145203
Documento
Autor
Nombre completo
Mariana Schutzer Ragghianti Zangrando
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Paulo, 2010
Director
Tribunal
Lima, Luiz Antonio Pugliesi Alves de (Presidente)
Casati, Marcio Zaffalon
Cavalcanti, Marcelo de Gusmao Paraiso
Pustiglioni, Francisco Emilio
Souza, Sergio Luis Scombatti de
Título en portugués
Análise radiográfica do tratamento de defeitos infra-ósseos humanos por meio de retalho de espessura total reposto associado ou não à proteína da matriz do esmalte: resultados após dois anos
Palabras clave en portugués
Periodontia
Periodontia (Regeneração)
Radiografia
Técnicas de diagnóstico e procedimentos
Resumen en portugués
O objetivo deste estudo clínico aleatório, boca dividida e duplo cego foi avaliar por meio de mensurações radiográficas lineares, o tratamento de defeitos infra-ósseos de 2 ou 3 paredes com retalho de espessura total reposto (RET) associado ou não à proteína derivada da matriz do esmalte (PME) após 24 meses. Foram avaliados 10 pacientes com periodontite crônica apresentando 2 ou mais defeitos infra-ósseos, totalizando 43 defeitos. As tomadas radiográficas foram realizadas antes do procedimento cirúrgico e após 24 meses. Foram confeccionados registros oclusais individualizados para padronização das radiografias. As películas radiográficas foram digitalizadas (500dpi/8bits) em um escaner (SprintScan 35 Plus scanner-Polaroid). O software AxioVision (version 3.0-Carl Zeiss) foi utilizado para mensurar as distâncias da junção esmalte-cemento (JEC) à crista óssea alveolar (CO), JEC ao fundo do defeito (FD) e o ângulo do defeito infra-ósseo. Uma escala milimétrica foi adquirida através da calibração de uma tela radiográfica de 1x1mm. Um examinador cego e calibrado realizou todas as mensurações radiográficas. A análise estatística utilizou nível de significância p=0,05. Após 24 meses, foi observada uma significante perda da crista óssea (JEC-CO) para PME (1,01mm; p=0,049), mas não para RET (0,14mm; p=0,622), no entanto, sem diferenças estatisticamente significantes entre os grupos (p=0,37). A redução da profundidade do defeito ósseo (JEC-FD) foi significante para RET (0,70mm; p=0,005), mas não para PME (-0,04mm; p=0,86), sem diferenças detectadas entre os grupos (p=0,87). Ambos PME (0,69; p=0,82) e RET (5,71; p=0,24) demonstraram um aumento nas medidas do ângulo do defeito, mas sem diferenças após 24 meses ou entre os grupos (p=0,35). Nesta amostra, a análise por meio de medidas radiográficas lineares computadorizadas não foi capaz de demonstrar superioridade do tratamento de defeitos infra-ósseos de 2 e 3 paredes com a aplicação da PME em comparação ao RET após 24 meses.
Título en inglés
Radiographic analysis of the treatment of human infrabony defects using repositioned flap associated or not to enamel matrix protein: results after two years
Palabras clave en inglés
Periodontics
Periodontics (Regeneration)
Procedures and diagnostic techniques
Radiography
Resumen en inglés
The aim of this randomized, double-blind, split-mouth clinical trial was evaluate, using linear radiographic measurements, infra-bony defects treated with enamel matrix protein (EMP) or repositioned flap (RF), after 24 months. Ten healthy patients with chronic periodontitis presenting 2 or more defects were selected, totalizing 43 defects. Radiographic data were collected just before surgery and after 24 months. An individualized film holder was used to take standardized radiographs. Images were digitized (500dpi/8bits) with the SprintScan 35 Plus scanner (Polaroid). The AxioVision (version 3.0) software (Carl Zeiss) was used to measure the distances from the cemento-enamel junction (CEJ) to the alveolar crest (AC), CEJ to the bottom of the defect (BD) and infra-bony defect angle. A milimetric scale was achieved after calibration with a 1x1mm grid. A blind calibrated examiner performed all radiographic measurements. Statistical analysis used a level of significance of p=0,05. After 24 months, a significant crestal bone loss (CEJ-AC) was observed for EMP (1,01mm; p=0,049) but not for RF (0,14mm; p=0,622), however, no differences were detected between groups (p=0,37). Reduction of the bone defect depth (CEJBD) was significant for RF (0,70mm; p=0,005) but not for EMP (-0,04mm; p=0,86), while no differences were detected between them (p=0,87). Both EMP (0,69; p=0,82) and RF (5,71; p=0,24) showed an improvement in defect angle measurements but no significant differences were observed after 24 months or between them (p=0,35). In this sample, the linear radiographic analysis was not able to demonstrate the superiority of EMP treated infra-bony defects when compared to RF alone after 24 months.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2011-04-08
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.