• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Tesis Doctoral
DOI
https://doi.org/10.11606/T.23.2010.tde-30082010-150345
Documento
Autor
Nombre completo
Geraldo Prestes de Camargo Filho
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Paulo, 2010
Director
Tribunal
Luz, Joao Gualberto de Cerqueira (Presidente)
Buscatti, Marcio Yara
Campos, Antonio Carlos de
Marques, Eduvaldo Silvino de Brito
Procopio, Antonio Silvio Fontao
Título en portugués
Estudo comparativo de duas técnicas de enxerto autógeno utilizando piezocirurgia para levantamento de seio maxilar
Palabras clave en portugués
Enxerto
Seio maxilar
Ultrassom
Resumen en portugués
A técnica de levantamento de seio maxilar apresenta como uma possível complicação a perfuração da membrana sinusal. A utilização de dispositivos ultrassônicos apresenta-se como uma interessante ferramenta, particularmente segura e eficiente para realização das ostectomias de parede sinusal e divulsão de membrana sinusal. O presente trabalho teve por objetivo comparar duas técnicas que utilizam a cirurgia ultrassônica para realização de enxerto autógeno para levantamento de seio maxilar. Dez coelhos foram utilizados no estudo, sendo que um deles não foi submetido a procedimento cirúrgico. Os nove coelhos operados tiveram os seios maxilares preenchidos com enxertos autógenos coletados de díploe externa de calota craniana, nas formas particulado do lado direito e raspado do lado esquerdo, ambos com aparelho ultrassônico. Os dados de densidade óssea nos seios maxilares esquerdo e direito, obtidos por meio de tomografia computadorizada nos sentidos transversal e longitudinal, registrados 90 dias após a realização dos enxertos foram comparados estatisticamente. Cortes histológicos das áreas enxertadas foram realizados com finalidade descritiva. Não houve diferenças estatisticamente significantes entre as técnicas de enxerto que utilizaram osso raspado e particulado coletado por meio de dispositivo ultrassônico da calota craniana de coelhos. O aspecto histológico observado após 90 dias foi semelhante nos dois grupos, mostrando tecido ósseo maduro em meio a tecido conjuntivo frouxo. Os procedimentos transoperatórios nos levaram a concluir que o ultrassom piezoelétrico mostrou-se um instrumento seguro na abordagem cirúrgica do seio maxilar de coelhos, permitindo a manutenção da integridade da membrana sinusal durante as manobras cirúrgicas.
Título en inglés
Comparative study of two autogenous graft techniques using piezosurgery for sinus lifting
Palabras clave en inglés
Graft
Maxillary sinus
Ultrasound
Resumen en inglés
Maxillary sinus lifting is a technique which presents as a possible complication the sinus membrane perforation. The use of ultrasonic devices is presented as an interesting tool, particularly safe and efficient to perform ostectomies of sinus wall and dissection of sinus membrane. This study aimed to compare two techniques that used ultrasound surgery to perform autogenous graft for maxillary sinus lifting. Ten rabbits were used in the study, one of which did not undergo surgery. The other nine rabbits had their maxillary sinuses filled with autogenous bone grafts collected from the external skull diploe in particulate form on the right side and shaved on the left side, both with ultrasonic device. Data on bone density in left and right maxillary sinus, obtained by computed tomography in transverse and longitudinal sections, recorded 90 days after the grafts, were compared statistically. Histological sections of the grafted areas were performed with descriptive purposes. There were no statistically significant differences between the two techniques that used shaved and particulate bone collected by means of ultrasonic device of the skull of rabbits. Histological aspects after 90 days were similar in both groups, showing mature bone through a fibrous connective tissue. Operatory assessment procedures leads us to conclude that the piezoelectric ultrasound showed as a safe tool in the surgical approach of the maxillary sinus of rabbits, allowing the maintenance of sinus membrane integrity during surgical procedures.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2010-09-02
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.