• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Thèse de Doctorat
DOI
https://doi.org/10.11606/T.23.2010.tde-18112010-103845
Document
Auteur
Nom complet
Mônica Nogueira Pigozzo
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Paulo, 2010
Directeur
Jury
Lagana, Dalva Cruz (Président)
Mesquita, Marcelo Ferraz
Noritomi, Pedro Yoshito
Pellizzer, Eduardo Piza
Zanetti, Artemio Luiz
Titre en portugais
Avaliação das tensões transmitidas às estruturas de suporte, por meio da associação dos métodos fotoelástico e de elementos finitos, decorrentes das forças aplicadas sobre overdentures retidas em implantes com sistema de encaixe barr
Mots-clés en portugais
Análise fotolelástica
Elemento finito
Implantes endoósseos
Overdentures
Resumé en portugais
O objetivo desta pesquisa foi avaliar in vitro as tensões transmitidas às estruturas de suporte, por meio da associação dos métodos fotoelásticos e elementos finitos, decorrentes da aplicação de forças sobre overdentures retidas em implantes com sistema de encaixe barraclipe, particularmente quando duas posições dos implantes são simuladas. Assim, dois modelos fotoelásticos de mandíbulas foram confeccionados, com dois implantes cada um, posicionados na região interforaminal a 22 mm de distância: modelo 1, denominado AFIP, modelo fotoelástico com implantes paralelos e orientados verticalmente; e modelo 2, denominado AFII, modelo fotoelástico com implantes angulados 10º em relação à linha média da mandíbula. Sobre os implantes, em cada modelo, foi posicionada uma prótese tipo overdenture, com sistema de retenção barra-clipe. Para simulação da mucosa, foi interposta entre a base da prótese e o rebordo residual uma camada de 2 mm de silicone. Este mesmo modelo foi representado para uma análise tridimensional (3D) de elementos finitos. As estruturas foram consideradas homogêneas, isotrópicas e lineares, além de serem atribuídas as correspondentes propriedades mecânicas para cada uma delas. Foram simuladas quatro mandíbulas de elementos finitos, sendo modelo 1, denominado EFRIP, com implantes paralelos; modelo 2, denominado EFRII, com implantes angulados em 10º, ambos modelos (1 e 2) simulando o modelo mandibular de resina fotoelástica; modelo 3, denominado EFOIP, com implantes paralelos; e modelo 4, denominado EFOII, com implantes angulados em 10º, ambos os modelos (3 e 4), simulando os ossos cortical e trabecular. Foram aplicadas cargas de 0,5; 1,0; 1,5; 2,0 e 3 bar no método fotoelástico e 0,1 MPa no método de elementos finitos e em seguida as imagens foram fotografadas e analisadas. Os resultados mostraram que: não houve semelhança entre as áreas de tensão dos modelos de resina fotoelástica, quando avaliada a angulação dos implantes (modelo 1 AFIP - e modelo 2 AFII). Houve semelhança entre as áreas de tensão nos modelos de elementos finitos com mandíbula em resina (modelo 1 EFRIP - e modelo 2 EFRII), tendo ocorrido o mesmo entre os modelos de elementos finitos com simulação de osso (modelo 3 - EFOIP - e modelo 4 EFOII) quando avaliada a inclinação dos implantes. Quando comparados os diferentes modelos com a mesma angulação de implante, observou-se que houve semelhança na distribuição das áreas de tensão entre os modelos 1 (AFIP e EFRIP), com uma alta concentração de tensão nos ápices dos implantes. Porém, não houve relação entre os modelos de implantes inclinados, modelos 2 (AFII e EFRII). Da mesma forma, não houve relação entre os modelos de análise fotoelástica e elementos finitos com simulação de mandíbula em resina, independentemente da angulação dos implantes, comparado os modelos de elementos finitos com simulação de osso. Frente às limitações do presente trabalho, concluiu-se que a associação dos métodos de análise fotoelástica e de elementos finitos é de grande valia para a obtenção de informação em relação à biomecânica referente a esse tipo de prótese e sistema de retenção. Além disso, houve semelhança nas áreas de concentração de tensão, quando comparado os modelos de análise fotoelástica e de elementos finitos, quando as propriedades mecânicas inseridas no modelo de elementos finitos foram compatíveis com o modelo fotoelástico, pois, quando o modelo de elementos finitos simulou uma mandíbula com diferenciação entre osso cortical e medular, as áreas de concentração de tensão sofreram alterações.
Titre en anglais
Appraisal, by association of photoelastic and finite elements methods, of load transmission on support structures with overdentures retained in implants with bar-clip system
Mots-clés en anglais
Finite Elements
Implants
Overdentures
Photoelastic Analysis
Resumé en anglais
The objective of this study was to appraise in vitro the load transmission in bar-clip retention system for overdenture when two implant positions are simulated, using for this purpose the association of photoelastic analysis and finite elements techniques. Therefore, two photoelastic mandible were manufactured with two implants each one, positioned in interforaminal region within 22 mm of distance: (i) model 1, named AFIP, photoelastic model with parallel and vertically oriented implants; and (ii) model 2, named AFII, photoelastic model with 10º angled implants in relation to mandible midline. A bar-clip retention system and an overdenture were fixed over both implants. To simulate oral mucosa were added a 2 mm silicon layer between overdenture prosthesis and photoelastic mandible. This same model was submitted to finite elements analysis in 3D, being attributed the correspondent mechanic properties to each structure analyzed and also being considered homogenous, isotropic and linear characteristics. Four finite elements mandible were simulated, (i) one with parallel implants and (ii) other with 10º angled implants, simulating photoelastic resin in mandible (models 1 and 2, named EFRIP and EFRII respectively); and a another couple of mandibles also with (iii) parallel and (iv) 10º angled implants, simulating cortical and cancellous bones in mandible (models 3 and 4, named EFOIP and EFOII respectively). 0.5; 1.0; 1.5; 2.0 and 3.0 bars loads were applied and correspondent images were analyzed. Results evidenced that there is no similarity in loaded areas between photoelastic resin models, when the implant angle is appraised in models 1 and 2 (AFIP and AFII). Notwithstanding, there are similarity between loaded areas in finite elements model with resin mandible, models 1 and 2 (EFRIP and EFRII), and the same have occurred with finite elements models with bone simulation, models 3 and 4 (EFOIP and EFOII), when appraised implant inclination. When different models are compared with the same implant angulations, was noted that there was similarity in the distribution of loaded areas between models 1 (AFIP and EFRIP), with high concentration of tension forces at the implant apex. Nevertheless, there was no relation between inclined models 2 (AFII and EFRII). At the same direction, there was no relation between photoelastic analysis and finite elements with resin model, with no influence of implant angulations, with finite element models with bone simulation. Considering the limitations of this study, it was concluded that association of photoelastic analysis and finite elements has a high potential value for obtaining information concerning the biomechanics of this kind of prosthesis and retention system; furthermore, there was similarity in areas where loads were applied, when compared photoelastic and finite elements models, provided that finite elements mechanic properties are compatible with photoelastic model, since concentration areas of tension forces suffer changes when finite elements model simulates a mandible with cortical and cancellous bones differentiation.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Date de Publication
2010-12-01
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.