• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Tesis Doctoral
DOI
https://doi.org/10.11606/T.23.2013.tde-05062013-172138
Documento
Autor
Nombre completo
Priscila Galzo Marafon
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Paulo, 2013
Director
Tribunal
Mattos, Beatriz Silva Camara (Presidente)
Daruge, Rudiney Jeferson
Noritomi, Pedro Yoshito
Saboya, Antonio Carlos Lorenz
Silva, Jorge Vicente Lopes da
Título en portugués
Avaliação da posição do modelo auricular virtual gerado por imagem captada com escâner a laser e desenvolvimento de dispositivo posicionador 3D
Palabras clave en portugués
Medidas lineares
Pontos antropométricos
Prótese auricular
Sistema CAD/CAM
Resumen en portugués
Este trabalho fundamenta a aquisição de modelo digital auricular por meio do escâner de superfície e avalia o posicionamento tridimensional do modelo auricular digital, espelhado segundo medidas antropométricas faciais, com e sem referência anatômica do canal auditivo externo, bem como desenvolve um dispositivo posicionador tridimensional para prótese auricular. Os dados de dez indivíduos voluntários, adultos maiores de 25 anos de idade, não portadores de lesão congênita ou adquirida na região craniofacial e de ambos os gêneros foram submetidos ao Teste dos Postos Sinalizados de Wilcoxon (p0,05) e a medida angular C6 foi avaliada de forma porcentual. Os resultados demonstram que ocorre assimetria nas medidas lineares da posição dos modelos auriculares direitos e esquerdos espelhados nos respectivos lados contralaterais da face sem a referência do conduto auditivo externo, sendo duas vezes mais frequente no espelhamento do modelo auricular esquerdo no lado direito da face. Observa-se menor assimetria dos modelos auriculares direitos espelhados no lado esquerdo da face e simetria na posição dos modelos esquerdos espelhados no lado direito da face, com a referência do conduto auditivo externo. A medida angular C6 apresenta menor assimetria na posição dos modelos auriculares direitos do que nos esquerdos, espelhados nos respectivos lados contralaterais da face, com e sem a referência do conduto auditivo externo. Conclui-se que a utilização do conduto auditivo externo como referência anatômica proporciona melhor simetria linear e angular da posição dos modelos auriculares virtuais direitos e esquerdos, espelhados nos respectivos lados contralaterais da face. O dispositivo posicionador projetado possibilita o ajuste das assimetrias detectadas no espelhamento de modelos auriculares, promovendo a compensação das discrepâncias evidenciadas durante o planejamento virtual para posicionamento do modelo auricular.
Título en inglés
Evaluation of the position of the virtual auricular model generated by image captured by laser scanning and development of 3D positioner device
Palabras clave en inglés
Anthropometric landmarks
Auricular prosthesis
CAD/CAM system
Linear mensurements
Resumen en inglés
This study substantiates the acquisition of auricular digital model, by means of surface scanner, and assesses the placement of three-dimensional auricular digital models, mirrored according to facial anthropometric measurements, with and without anatomical reference of the external auditory canal, as well as developing a prosthetic device for three-dimensional positioning of the mirrored auricular model. The digital data of ten volunteers, adults over 25 years old, not suffering from congenital or acquired lesions in the craniofacial region and of both genders underwent Wilcoxon Ranking Test (p0.05) and angular measurement C6 was assessed as percentage. The results show that occurs asymmetry regarding the linear measurements in the positioning of the right and left ear models when mirrored in their contra lateral side of the face without reference of the external auditory canal, being twice as common in mirroring the left auricular model on the right side of the face. It is observed less asymmetry in the right auricular models mirrored on the left side of the face and symmetry in the positioning of the left models mirrored on the right side of the face, with the reference of the external auditory canal. The angular measurement C6 shows less asymmetry in the positioning of the models right auricular model than in those of the left, mirrored in their contra lateral side of the face, with or without reference to the external auditory canal. The use of the external auditory canal as anatomical reference provides better linear and angular symmetry in positioning the virtual auricular right and left models, mirrored in their contra lateral side of the face The three-dimensional positioner device designed enables the adjustment of the asymmetries found in mirroring the digital auricular models, providing compensation for discrepancies evidenced during the virtual positioning of the auricular model.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2013-07-12
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.