• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Tesis Doctoral
DOI
https://doi.org/10.11606/T.23.2012.tde-13042013-121516
Documento
Autor
Nombre completo
Giorgia Borges de Carvalho
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Paulo, 2012
Director
Tribunal
Dias, Reinaldo Brito e (Presidente)
Almeida, Fernanda Campos Sousa de
Haddad, Aida Sabbagh
Loducca, Francisco Eugenio
Silva, Dorival Pedroso da
Título en portugués
Análise fotoelástica das cargas aplicadas em próteses parciais removíveis nas grandes perdas de maxila
Palabras clave en portugués
Fotoelasticidade
Odontologia
Prótese Bucomaxilofacial
Prótese Parcial Removível
Reabilitação
Resumen en portugués
Este trabalho teve a finalidade de avaliar pela técnica fotoelástica, o efeito que a prótese parcial removível teria, em aliviar as tensões sobre as raízes dos dentes. Para tanto preparamos um modelo com três tipos de desenhos de próteses parciais removíveis, simulando uma reabilitação nas grandes perdas de maxila. Todos os modelos de desenhos apresentaram planos guias em incisivo central e segundo molar, e se diferenciaram da seguinte forma: modelo 01, grampo circunferencial simples em canino, grampo gêmeo entre primeiro e segundo pré-molar e grampo gêmeo entre primeiro e segundo molar; modelo 02, utilizamos os mesmos grampos colocados no modelo 01 incluindo neste modelo um recobrimento palatino, modelo 03, grampo gêmeo entre canino e primeiro pré-molar, grampo gêmeo entre segundo pré-molar e primeiro molar e grampo circunferencial simples em mesial de segundo molar. Foram aplicadas cargas verticais de 10 kg, 15 kg e 20 kg em canino, segundo pré-molar e primeiro molar. Os resultados permitiram concluir que: Os planos guia comprovaram sua efetividade através do contato pleno nos dentes preparados para o seu assentamento. O recobrimento palatino não amenizou as cargas nas raízes dos dentes. Os grampos gêmeos, colocados em uma posição mais anterior, indicam uma distribuição melhor das tensões. Os grampos circunferenciais simples, colocados mais posteriormente, indicam uma melhor distribuição das tensões. Os modelos 01 e 02 apresentaram maiores tensões em incisivo central comparados com o modelo 03. O modelo 03 foi o que melhor distribuiu as cargas de forma mais equilibrada mostrando tensões de menor magnitude. Os melhores modelos de próteses parciais removíveis, pela perspectiva de transferência de tensão foram primeiramente o modelo 03, depois o modelo 01 e por fim o modelo 02. A mudança do desenho da PPR alterou a distribuição das tensões nos dentes dos modelos avaliados.
Título en inglés
Photoelastic analysis of the loads applied to removable partial dentures in large ressections of maxilla
Palabras clave en inglés
Dentistry
Maxillofacial Prosthodontics
Photoelasticity
Rehabilitation
Removable Partial Denture
Resumen en inglés
This study aimed to evaluate by the photoelastic technique, the effect that the partial denture would have to reduce tensions on the roots of teeth. For this reason, was prepared a model with three types of removable partial dentures designs, simulating rehabilitations in large ressections of maxilla. All models presents guide-planes on central incisor and second molar, and was differentiated as follows: Model 01, simple circumferential clasp in canine, twin clasps between first and second premolar and twin clasps between first and second molar; model 02, we use the same clasps as model 01 only including a palatal covering in this model, model 03, twin clasps between canine and first premolar, twin clasps between second premolar and first molar and simple circumferential clasp at mesial of second molar. Were applied vertical loads of 10 kg, 15 kg and 20 kg in canine, second premolar and first molar. The results showed that: The guide-planes proved its effectiveness through full contact in the teeth prepared for their settlement. The palatal covering failed to alleviate the stress on the roots of teeth. Twins clasps, placed in a more anterior position, indicating a better distribution of stresses. Simple circunferencial clasp, placed in a more posterior position indicating a better distribution of stresses. Models 01 and 02 had higher tensions in central incisor compared with the model 03. The Model 03 was the best considering equilibrated load distribution showing stress of lesser magnitude. The best models of removable partial dentures, from the perspective of stress transfer were first model 03, followed by the model 01 and then finally the model 02. The change os design of RPD changed the distributions os tensions in teeth of evaluated models.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2013-05-27
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.