• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Master's Dissertation
DOI
https://doi.org/10.11606/D.25.2003.tde-18032005-145630
Document
Author
Full name
Cintia Gaio Murad
Institute/School/College
Knowledge Area
Date of Defense
Published
Bauru, 2003
Supervisor
Committee
Ishikiriama, Aquira (President)
Francisconi, Paulo Afonso Silveira
Pascotto, Renata Corrêa
Title in Portuguese
"Avaliação da resistência a tração de reparos em resina composta".
Keywords in Portuguese
dentística
resinas compostas
resistência à tração
Abstract in Portuguese
Este trabalho foi desenvolvido com o objetivo de avaliar in vitro a resistência adesiva em reparos de resina composta utilizando um sistema adesivo, com uso prévio ou não de silanizadores na área de emenda, em corpos de prova submetidos a testes de tração. Esses foram preparados em um dispositivo de aço inoxidável que fornecia corpos de prova em forma de halteres. Oitenta metades de corpos de prova foram confeccionados com resina composta microhíbrida Esthet-X (Dentsply Indústria e Comércio Ltda.), obtendo-se assim, os hemi-halteres. Após permanecerem armazenados em água destilada durante quinze dias, os meio espécimes tiveram a interface do reparo desgastada com uma ponta diamantada, em seguida, condicionada por trinta segundos com ácido fosfórico 37%, lavada com água por vinte segundos, e seca com ar comprimido. Os hemi-halteres foram divididos em quatro grupos de vinte espécimes, em que cada grupo recebeu um sistema adesivo: Grupo I: uma camada de adesivo Prime&Bond 2.1 (Dentsply Indústria e Comércio Ltda.); Grupo II: uma camada de silano (Silano – Dentsply Indústria e Comércio Ltda.) mais uma camada de adesivo; Grupo III: uma camada de silano; Grupo IV: três camadas de silano. Os espécimes foram recolocados no dispositivo metálico, e o reparo foi completado com a inserção da mesma resina composta. Estes foram mantidos em água destilada novamente, por 24 horas, e submetidos a teste de tração na máquina de ensaio universal EMIC, com velocidade de carregamento de 0,5mm/min. Os testes estatísticos aplicados foram Análise de Variância a um critério – ANOVA – seguido de Teste de Tukey (p<5%). Os resultados obtidos foram (média ± desvio padrão) para o Grupo I: 28,93 ±7,68; Grupo II: 27,87±9,57; Grupo III: 20,59±5,82 e Grupo IV: 22,0±6,69, demonstrando que a aplicação de adesivo tem influência positiva, estatisticamente significante na resistência à tração, comparado com a aplicação isolada do silano. A associação adesivo/silano não demonstrou vantagem em relação ao uso isolado do agente adesivo, e o uso de três camadas de silano não elevou a resistência adesiva comparada com a aplicação da camada única.
Title in English
Traction strength assessment of repairs in composite resin
Abstract in English
The aim of this study was to evaluate in vitro the tensile bonding strength of repairs in composite resin using an adhesive system, with or without the previous use of silane on the junction of test bodies submitted to traction tests. The test bodies were prepared in a stainless steel device that provides the shape of a dumb-bell. Eighty half-test bodies were manufactured with microhybrid composite resin Esthet-X (Dentsply) in the shape of half dumb-bells. After being stored in distilled water for fifteen days, the repair surfaces were abraded with a diamond bur, conditioned in phosphoric acid at 37% for 30 seconds, rinsed with water and air-dried. After that, the half test bodies were divided into four groups of twenty units, and each group received one type of adhesive system: Group I: one layer of adhesive system Prime&Bond 2.1 (Dentsply); Group II: one layer of silane (Silano – Dentsply) plus one layer of adhesive system; Group III: one layer of silane and Group IV: three layers of silane. The specimens were put back into the metallic device and the repair was carried out with the same composite resin. They were again kept in distilled water for 24 hours and submitted to a traction test in an EMIC universal testing machine, with a loading speed of 0.5 mm/min. The data was analyzed by ANOVA and Tukey’s test (p<5%). The results obtained were (mean ± standard deviation) for Group I: 28,93±7,68; Group II: 27,87±9,57; Group III: 20,59±5,82 and Group IV: 22,0±6,69, showing that the use of an adhesive system has positive, statistically significant, influence on the restoration tensile bonding strength, compared with using silane alone. The association adhesive/silane didn’t show advantage compared with the use of the adhesive system alone, and the use of three layers of silane didn’t improve the bonding strength on the use of just one layer.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
CintiaGaioMurad.pdf (1.01 Mbytes)
Publishing Date
2005-04-04
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.