• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Master's Dissertation
DOI
https://doi.org/10.11606/D.25.2003.tde-11082005-112346
Document
Author
Full name
Luciana Martins Crês Moraes
Institute/School/College
Knowledge Area
Date of Defense
Published
Bauru, 2003
Supervisor
Committee
Bonachela, Wellington Cardoso (President)
Giampaolo, Eunice Teresinha
Valle, Accacio Lins do
Title in Portuguese
Avaliação da adaptação vertical entre intermediários do tipo esteticone e cilindros metálicos pré-usinados, variando as condições: sobrefundição, torques e parafusos de fixação
Keywords in Portuguese
implantes dentários
prótese
Abstract in Portuguese
A adaptação de próteses sobre implantes é considerada um fator primordial para o sucesso destas longitudinalmente. Este estudo observou a adaptação vertical entre intermediário tipo esteticone e cilindros pré-fabricados antirotacionais para próteses unitárias em diferentes ligas. Foram selecionados cilindros de ouro da empresa Conexão (Conexão Sistemas de Prótese - São Paulo- SP- Brasil) e cilindros de níquel/cromo pré-fabricados em um laboratório comercial. A mensuração da adaptação vertical foi realizada em microscópio óptico, antes da sobrefundição, ao torque de 10Ncm e 20Ncm variando-se os parafusos de fixação. Encontraram-se medidas que variaram de 14,02 ± 5,63 µm para os cilindros de níquel/cromo, antes da sobrefundição ao torque de 10Ncm, e 10,95 ± 5.68 µm para o torque de 20Ncm. E para os cilindros de ouro, ao torque de 10Ncm, a média encontrada foi de 14,41 ± 3,84 µm e ao torque de 20Ncm foi de 12,26 ± 3.69 µm. Após as leituras iniciais, os cilindros receberam enceramento, foram incluídos e fundidos com ligas de paládio/prata para o cilindro de ouro, e níquel/cromo para o cilindro de níquel/cromo e novamente analisados. As medidas variaram de 20,93 ± 7,10 µm a 10Ncm e 15,77 ± 4,72 µm a 20Ncm para os cilindos de níquel/cromo fundidos em níquel /cromo, e de 11,79 ± 4,06 µm ao torque de 10Ncm e 9,59 ± 3,25 µm à 20Ncm para os cilindros de ouro sobrefundidos em paládio/prata. Os resultados obtidos demonstraram que o cilindros de ouro com maior torque apresentaram-se mais adaptados antes e após a sobrefundição. Foram encontradas diferenças estatisticamentes significantes também quando a liga de paládio/prata foi empregada. Concluiu-se então que as próteses unitárias sobre implantes são indicadas sendo que ligas nobres e seminobres apresentam menores variações estruturais.
Abstract in English
The fitting of prostheses over implants is regarded as a fundamental factor for their success in the long-term. This study evaluated the vertical fitting between esteticone abutments and anti-rotational prefabricated cylinder implants of several alloys for single-tooth prosthesis. Gold cylinders of the brand Conexao (Conexao Sistemas de Protese – Sao Paulo, SP, Brazil) and nickel-chromium cylinders prefabricated in a commercial laboratory were selected. Measurement of the vertical fitting was conducted in a light microscope, before overcasting with 10 Ncm and 20 Ncm of torque, with variations in the fixing screws. The measurements ranged from 14.03±5.63µm for the nickel-chromium cylinders before overcasting with 10 Ncm of torque and 10.95±5.68µm with 20 Ncm of torque. Concerning the gold cylinders, the values found were 14.41±3.84µm with 10 Ncm of torque and 12.26±3.69µm with 20 Ncm of torque. After the initial readings, the cylinders were submitted to waxing, investment and casting with palladium-silver alloy for the gold cylinders and nickel-chromium alloy for the nickel-chromium cylinders, and then reevaluated. The measurements revealed 20.93±7.10µm with 10 Ncm and 15.77±4.72µm with 20 Ncm for the nickelchromium cylinders cast with nickel-chromium, and 11.79±4.06µm with 10 Ncm and 9.59±3.25µm with 20 Ncm for the gold cylinder overcast with palladium-silver. The results demonstrated that the gold cylinders with the higher torque exhibited the best fitting before and after overcastting. Statistically significant differences were also observed with employment of the palladium-silver alloy. It was concluded that single-tooth implant-supported prosthesis may be indicated, being that noble and semi noble alloys present the smallest structural variations.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
Publishing Date
2005-08-16
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.