Title in Portuguese
Análise do estresse gerado em componentes de prótese fixa implanto-suportada através do uso de extensômetros
Keywords in Portuguese
implante dentário osseointegrado
prótese dentária
prótese parcial fixa
Abstract in Portuguese
O êxito clínico dos implantes osseointegrados é amplamente determi nado, pela maneira como o estresse mecânico é transferido do implante, ao tecido ósseo circundante, sem gerar forças de grande magnitude, o que poderia colocar em risco a longevidade do próprio implante e da restauração protética. Inúmeros aprimoramentos técnicos, assim como desenhos e ligas metálicas alternativas para a confecção de infra-estruturas, têm sido propostos para melhorar os procedimentos protéticos. O objetivo deste trabalho foi verificar a distribuição de estresse em componentes de prótese fixa implanto-suportada, através do uso de extensômetros, em função de duas ligas metálicas. Corpos de prova simulando infra-estruturas para uma situação de prótese total fixa mandibular, foram confeccionados em liga de cobalto -cromo e paládio-prata e posicionados sobre um modelo-mestre. Uma carga estática vertical de 100N foi aplicada na extremidade livre, a uma distância de 10, 15 e 20mm para distal do centro do intermediário terminal. Os resultados demonstraram que em grandes extensões de cantilever, a liga de cobalto-cromo apresentou um padrão de distribuição de forças semelhante à liga de paládio-prata com cantilever curto. Independente do local de aplicação da força e da liga utilizada na confecção das infra-estruturas, o intermediário mais próximo do ponto de aplicação da carga foi o que registrou a maior deformação específica. O emprego de uma liga de cobalto-cromo na confecção de infra-estruturas para prótese sobre implantes pode permitir braços de cantilever mais extensos.
Abstract in English
The clinical success of osseointegrated implants are largely influenced by the manner mechanical stresses are transfered from implant to surrounding bone, without generating forces of a magnitude that would jeopardize the longevity of implant and prosthesis. A variety of technical improvements, as well as alternative framework designs and alloys have been reported to improve prosthetic procedures. The aim of this study was to analyse stress distribution on components of a fixed implant-supported prostheses, fabricated with two metal alloys. The samples simulated a typical mandibular fixed complete -arch framework and were fabricated on cobalt-chromium alloy and palladium-silver alloy and positioned on a master-cast. A vertical estatic load of 100N was applied on the cantilever arm at a distance of 10, 15 and 20mm from the center of distal abutment. Strain gauges were positioned on the mesial and distal aspects of each abutment to capture deformation.The results demonstrated that for large cantilever extensions, the cobalt-chromium alloy presented a pattern of force distribution similar to that observed with palladium-silver alloy with short cantilever. Irrespective of the point of load application and the metal alloy used in the framework construction, the abutment closer to the point of load application registered the highest especific deformation. Using a cobalt-chromium alloy may allow longer cantilever arms.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
Publishing Date
2005-04-04
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.