• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Tesis Doctoral
DOI
https://doi.org/10.11606/T.25.2003.tde-21032005-135504
Documento
Autor
Nombre completo
Mariza Akemi Matsumoto
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
Bauru, 2002
Director
Tribunal
Taveira, Luis Antonio de Assis (Presidente)
Consolaro, Alberto
Kawakami, Roberto Yoshio
Nary Filho, Hugo
Sanches, Márcio Giampietro
Título en portugués
Avaliação da resposta tecidual frente a diferentes materiais de fixação em enxertos ósseos autógenos: análise microscópica morfológica
Palabras clave en portugués
análise morfológica
enxerto ósseo
microscopia
Resumen en portugués
Os enxertos ósseos autógenos têm sido largamente empregados para a reconstrução de rebordos atróficos. A fixação destes enxertos é fundamental no fenômeno de reparação óssea, propiciando a incorporação ao leito receptor e rápida revascularização. Placas e parafusos sintéticos reabsorvíveis têm sido desenvolvidos na tentativa de minimizar alguns pontos negativos dos materiais metálicos rotineiramente utilizados para esta finalidade. O presente estudo avaliou comparativamente as condições ósseas locais de enxertos ósseos autógenos oriundos da região mentoniana quando em contato com parafusos de ácido poliglicólico (PGA)/ácido poli (L-láctico) (PLA) e de titânio. Para esta avaliação, participaram sete pacientes apresentando atrofias maxilar e mandibular severas, impossibilitando a reabilitação com implantes osteointegráveis. Após quatro meses das cirurgias de enxerto, as áreas onde se localizavam os parafusos de teste foram biopsiadas com brocas trefinas, obtendo-se os espécimes a serem submetidos a procedimento histotécnico de rotina e corados em H.E. e Tricrômico de Mallory para avaliação morfológica em microscopia óptica de luz. A partir desta análise observouse, adjacente aos parafusos de titânio, tecido ósseo viável, com eventuais áreas recobertas por células de revestimento e ausência de reabsorção. Adjacente aos parafusos reabsorvíveis, o tecido ósseo também apresentou viabilidade morfológica, porém, com presença de extensa faixa de tecido conjuntivo fibroso interposto, e eventuais células gigantes. Estes resultados sugerem que ambos os métodos de fixação proporcionaram condição de reparo no local de enxertos, contudo, os parafusos reabsorvíveis induziram reação inflamatória mais extensa que os de titânio, caracterizada por reação tipo corpo estranho.
Título en inglés
Evaluation of tissue response due to different fixation materials in autogenous bone grafts: microscopic morphological analysis
Resumen en inglés
Autogenous bone grafts have been largely used for the reconstruction of severely atrophic ridges. The fixation of these grafts plays an important role in bone graft repair, leading to the integration to the receptor bed and early revascularization. Resorbable plates and screws are being developed in an attempt to minimize some negative aspects of the metallic devices routinely used in this procedure. The present work evaluated comparatively local bone conditions of autogenous grafts retrieved from the chin, in contact with polyglicolic / poly (L-lactic) acid and titanium screws. Seven patients presenting severe maxillary atrophy, unabling rehabilitation with endosseous implants, participated in this study. After four months of the grafting, the regions containing the test screws were biopsied using trephine bur, the specimens retrieved undergone histological routine procedures, and stained with HE and Mallory Trichromic to be morphologically evaluated under light microscopy. From this analysis, viable bone tissue was noted around the titanium screws, eventually presenting lining cells with no signs of resorption. Around the resorbable screws, viable bone tissue was also observed, although, presenting a thick layer of connective tissue interposed between the screw and the bone, and eventual foreign body giant cells. These results suggest that both fixation method provided good condition of local repair, however, the resorbable screws induced a longer inflammatory phase than the titanium screws, characterized by foreign body reaction.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
MarizaAMatsumoto.pdf (2.76 Mbytes)
Fecha de Publicación
2005-04-04
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.