• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Disertación de Maestría
DOI
https://doi.org/10.11606/D.25.2016.tde-02022016-154831
Documento
Autor
Nombre completo
Janaina de Oliveira Moraes
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
Bauru, 2015
Director
Tribunal
Honório, Daniela Rios (Presidente)
Pinto, Lidiane de Castro
Valarelli, Thais Marchini de Oliveira
Título en portugués
Avaliação da qualidade do preparo de canais de dentes decíduos artificiais utilizando o sistema de rotação recíproca
Palabras clave en portugués
Endodontia
Instrumentação
Odontopediatria
Resumen en portugués
O objetivo deste estudo foi comparar o preparo de canais radiculares de dentes decíduos artificiais com o uso dos sistemas manual, rotatório e de rotação recíproca, no que diz respeito ao desgaste promovido após a instrumentação dos canais radiculares e o tempo necessário para a realização da instrumentação. Os fatores em estudo foram técnica de instrumentação em três níveis e área de avaliação no canal radicular em três níveis. Foram utilizados apenas os dentes multiradiculares (primeiro molar superior, segundo molar superior, primeiro molar inferior e segundo molar inferior), compondo 24 dentes os quais foram aleatoriamente divididos entre as três técnicas de instrumentação em estudo: manual, Sistema rotatório Mtwo e Sistema de rotação recíproca Reciproc. A unidade amostral foi conduto radicular (n=20). Os condutos radiculares foram escaneados no tomógrafo de TCFC (Accuitomo). Após a instrumentação dos dentes novas imagens foram realizadas, avaliações quantitativas foram feitas medindo-se nas imagens axiais dos canais radiculares, a espessura das paredes em três diferentes regiões: terços apical, médio e cervical. As variáveis de resposta analisadas foram cálculo do transporte do canal, cálculo da descentralização e tempo de instrumentação. Tanto para a avalição da descentralização, quanto para a avaliação do transporte, os dados foram transformados e analisados por ANOVA a 2 critérios e Teste de Tukey, para os dados da comparação dos tempos foi utilizado o teste de Kruskal-Wallis e Teste de Tukey (p<0,05). Para a avaliação do transporte do canal e da descentralização não foi encontrada diferença estatística significativa entre os tipos de instrumentação e terços radiculares (p>0,05). Na avaliação do tempo de preparo, o grupo do sistema reciprocante apresentou menor tempo de preparo em comparação com o sistema manual e rotatório (p<0,05). Desta forma conclui-se que os tipos de instrumentação avaliados promoveram um preparo similar dos canais, sem diferença entre os terços cervical, médio e apical, sendo que o sistema de rotação recíproca resultou em um menor tempo de instrumentação.
Título en inglés
Evaluation of the quality of preparation of artificial deciduous teeth canal using the reciprocal system of rotation canal preparation
Palabras clave en inglés
Endodontics
Instrumentation
Pediatric dentistry
Resumen en inglés
The objective of this study was to compare the preparation of root canals of artificial deciduous teeth with the use of the manual systems, rotational and reciprocal rotation, with regard the detrition promoted after instrumentation of root canals and the time necessary for the realization of instrumentation. The factors in study were the techniques of instrumentation in tree levels and the area of root canal in tree levels. Have been used only teeth multirooted (first molar, second molar, lower first molar and second molar), composing 24 teeth which were randomly divided among the three instrumentation techniques under study: manual, rotational system Mtwo and reciprocal rotation system Reciproc. The sample unit was root canal (n = 20). The root canals were scanned in tomographer CBCT (Accuitomo). After instrumentation of new images teeth were conducted quantitative evaluations were made by measuring the axial images of the root canals, the wall thickness at three different regions: apex, middle and cervical thirds. Response variables analyzed were calculating the channel transport, decentralization and calculation time instrumentation. Both for the evaluation of decentralization, as for the evaluation of transportation, data were processed and analyzed by ANOVA and Tukey 2 criteria test to the data comparing the times we used the Kruskal-Wallis test and Tukey test (p <0.05). For the evaluation of the channel transport and decentralization was no statistically significant difference between the types of instrumentation and root thirds (p> 0.05). In assessing the preparation time, the reciprocating system group showed less preparation time compared to the manual system and rotary (p <0.05). Thus it is concluded that the types of instrument reviews promoted a similar preparation of channels, no difference between the cervical, middle and apical thirds, and the reciprocal rotation resulted in a shorter time instrumentation.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2016-02-04
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.