• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Mémoire de Maîtrise
DOI
https://doi.org/10.11606/D.25.2013.tde-14082013-102351
Document
Auteur
Nom complet
Odair Bim Junior
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
Bauru, 2013
Directeur
Jury
Wang, Linda (Président)
Atta, Maria Teresa
Cebim, Marco Aurélio
Titre en portugais
Estratégias para adição de rodamina B em sistemas adesivos
Mots-clés en portugais
Diluição
Espectroscopia de fluorescência
Microscopia confocal
Rodamina
Sistemas adesivos
Resumé en portugais
A rodamina B e outros marcadores fluorescentes vêm sendo empregados na avaliação morfológica da interface de adesão com o auxílio de microscopia confocal de varredura a laser. Acrescentando-se rodamina B a sistemas adesivos, é possível observar as características de espessura da camada de adesivo, micromorfologia da camada híbrida, extensão e quantidade de tags, bem como diagnosticar defeitos ou alterações na interface de adesão. A literatura revela, entretanto, uma falta de precedentes sobre as quantidades de marcadores nos componentes resinosos. Além disso, ainda não se avaliou o efeito da concentração de rodamina B sobre a qualidade da análise da interface de adesão, bem como sobre o comportamento fotofísico dos marcadores nos sistemas adesivos. Este estudo foi realizado com o propósito de sistematizar um método de adição de rodamina B a sistemas adesivos, incluindo-se estratégias para a determinação de concentrações mínimas de rodamina nos componentes resinosos, porém, ainda viáveis para a realização da análise morfológica da interface de adesão através de microscopia confocal de varredura a laser. Para tal, os sistemas adesivos não simplificados e considerados padrão-ouro em suas categorias Adper™ Scotchbond™ Multi-Purpose (convencional de três passos) e Clearfil™ SE Bond (auto-condicionante de dois passos) foram modificados com rodamina B em cinco diferentes concentrações: C1 (0,5 mg/mL), C2 (0,10 mg/mL), C3 (0,02 mg/mL), C4 (0,004 mg/mL) e C5 (0,0008mg/mL) e o comportamento fluorescente da rodamina nos adesivos foi avaliado tanto no âmbito espectroscópico (espectroscopia de fotoluminescência), como no âmbito microscópico (microscopia confocal de varredura a laser). Para a modificação dos adesivos, utilizou-se uma técnica precisa de proporcionamento na qual o marcador fluorescente foi incorporado às resinas fluidas a partir de soluções de rodamina B em etanol. Os espectros de fluorescência mostraram diferenças nos máximos das bandas de emissão e de excitação, de acordo com as concentrações de rodamina B em cada material dispersante. A análise microscópica dos espécimes em dentina confirmou que é possível utilizar sistemas adesivos contendo rodamina B em concentrações muitas vezes menores do que as mencionadas na literatura. Ambos os sistemas avaliados puderam ser visualizados, microscopicamente, quando marcados com rodamina B nas três concentrações pré-selecionadas para a avaliação da interface de adesão: C2 (0,10 mg/mL), C3 (0,02 mg/mL) e C4 (0,004 mg/mL), sendo que C3 forneceu os melhores resultados em relação ao contraste e à saturação nas fotomicrografias. Concluiu-se que o comportamento fotofísico da rodamina B é influenciado tanto pela concentração, como pelo sistema adesivo no qual o marcador está dissolvido. A concentração de rodamina B também interfere na qualidade da análise morfológica da interface de adesão, sendo que o excesso do marcador pode dificultar a distinção de detalhes micromorfológicos.
Titre en anglais
Strategies for adding rhodamine B to bonding agents
Mots-clés en anglais
Adhesive systems
Confocal microscopy
Diluition
Fluorescence spectroscopy
Rhodamine
Resumé en anglais
Rhodamine B and other fluorescent markers have been used for the assessment of the bonding interface via confocal laser scanning microscopy. By adding rhodamine into adhesive systems, it is possible to study morphological characteristics of the hybrid layer, the extent and amount of resin tags and the adhesive layer thickness, as well as detecting potential defects or alterations at bonding interface. Meantime the literature reveals lack of standards among the quantities of fluorescent markers in resin-based polymers. The effects of rhodamine B concentration on the quality of the microscopic analysis, as well as on the photophysics of labeled adhesive systems were not assessed up to now. This study aimed to systematize methodologies for adding rhodamine B into adhesive systems, including suitable strategies for determining the minimum serviceable rhodamine concentrations to perform the morphological analysis of the bonding interface. Two non-simplified adhesive system considered gold standard categories Adper™ Scotchbond™ Multi-Purpose (3 steps conventional) and Clearfil™ SE Bond (2 steps self-etching) were modified with rhodamine B at five concentrations: C1 (0.5 mg/ml), C2 (0.10 mg/ml), C3 (0.02 mg/ml), C4 (0.004 mg/ml) and C5 (0.0008 mg/ml ) and the fluorescent behavior of the labeled resins was assessed both by photoluminescence spectroscopy and by confocal laser microscopy The preparation of the labeled resins was proceed by means of a precise proportioning technique in which the fluorescent marker was incorporated into the bonding agents from solutions of rhodamine B in ethanol. The fluorescence spectra showed differences in the intensity and wavelength fluorescence according to the rhodamine B concentration. Microscopic analysis of the dentin specimens confirmed adhesive systems can be modified with rhodamine B at far lower concentrations than those mentioned in the literature. Both evaluated systems were microscopically visualized while labeled with Rhodamine B at three pre-selected concentrations: C2 (0.10 mg/mL), C3 (0.02 mg/ml) and C4 (0.004 mg/ml), and C3 offered the best outcome with respect to contrast and saturation in photomicrographs. It was concluded that the photophysical behavior of rhodamine B depends on both the concentration and labeled adhesive system. The rhodamine B concentration also interferes with the quality of morphological analysis of the bonding interface, and the excess of the fluorescent marker may jeopardize the discrimination of morphological details.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Date de Publication
2013-08-15
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.