• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Master's Dissertation
DOI
https://doi.org/10.11606/D.25.2022.tde-18112022-112826
Document
Author
Full name
Bianca Rodrigues Terrabuio
Institute/School/College
Knowledge Area
Date of Defense
Published
Bauru, 2022
Supervisor
Committee
Bullen, Izabel Regina Fischer Rubira de (President)
Abujamra, Roberta Heiffig Handem
Capelozza, Ana Lucia Alvares
Tieghi Neto, Victor
Title in Portuguese
Contribuição da radiografia interproximal digital e tomografia computadorizada de feixe cônico na detecção de lesão de cárie proximal comparada à microtomografia computadorizada
Keywords in Portuguese
Cárie dentária
Microtomografia por raios X
Radiografia digital
Tomografia computadorizada de feixe cônico
Abstract in Portuguese
Devido à importância dos exames por imagem no auxílio para detecção de lesões cariosas proximais, o objetivo deste trabalho foi analisar a acurácia para detecção dessas lesões fornecida pela radiografia interproximal digital (RID), tomografia computadorizada de feixe cônico (TCFC) e microtomografia computadorizada (Micro- CT) como padrão-ouro, utilizando o sistema de pontuação radiográfico International Caries Detection and Assessment System (ICDAS). Para tanto, cento e quarenta dentes foram escaneados através do tomógrafo 3D Accuitomo 170 (J. Morita Mfg. Corp.) em três protocolos de TCFC e, pela análise das imagens, os dentes com classificação de 0 a 4 no sistema de pontuação radiográfico ICDAS foram selecionados para as próximas fases da pesquisa, na qual foram radiografados simulando a técnica interproximal com placa de fósforo (PSP) e escaneados no microtomógrafo Skyscan 1174 (Bruker). As imagens de Micro-CT foram, então, avaliadas por dois especialistas em Radiologia Odontológica para confirmar a presença, ou não, de lesão cariosa, bem como a sua classificação, e as respostas obtidas por meio dessa avaliação foram utilizadas como padrão-ouro. Em seguida, quatro examinadores dentistas avaliaram cada imagem de TCFC e de RID individualmente, por duas vezes, em um intervalo de quinze a trinta dias, também classificando a lesão encontrada de acordo com o sistema de pontuação radiográfico ICDAS de 0 a 4. Nesse processo, o número de dentes selecionados foi de 26, totalizando 52 faces (mesial e distal) analisadas, entre elas 26 faces hígidas (grau 0), 6 lesões grau 1, 7 lesões grau 2, 7 lesões grau 3 e 6 lesões grau 4. A partir disso, foram realizados o teste de Friedman, o teste Kappa Ponderado e os de acurácia, sensibilidade e especificidade, em que a significância de 5% foi aceita. A comparação entre os graus de classificação obtidos através da Micro-CT com TCFC e RID demonstrou diferença estatisticamente significativa apenas entre Micro-CT e as imagens de TCFC no protocolo Standard (p<0,001). O teste Kappa ponderado apresentou valores de boa (0,61 0,80) ou excelente (0,81 1,0) concordância intra e inter-examinadores, e os valores de acurácia, sensibilidade e especificidade, respectivamente, foram de 87%, 78,8% e 95,2% para protocolo de TCFC Hi- Resolution (Hi-Res), 85,1%, 71,1% e 99% para o Standard, 84,2%, 74,05% e 94,2% para o Hi-Fidelity (Hi-Fi) e 83,1%, 71,1% e 95,2% para a RID. Já a sensibilidade de cada método de imagem, de acordo com os graus de classificação 1, 2, 3 e 4, foram, respectivamente, 58,3%, 42,9%, 96,42% e 87,5% para a RID, 29,2%, 64,27%, 96,4% e 95,8% para o protocolo de TCFC Standard, 25%, 71,4%, 96,4% e 100% para o protocolo Hi-Fi e 33,3%, 78,5%, 100% e 95,8% para o protocolo Hi-Res. Conclui-se, portanto, que tanto a RID como a TCFC apresentam boa acurácia diagnóstica na detecção de lesão cariosa, mas, considerando os graus da lesão, a RID possui maior sensibilidade para detectar lesões cariosas incipientes e, para lesões em dentina, os métodos de imagem bi e tridimensional se equiparam. Apenas o protocolo Standard da TCFC não detectou os graus de classificação visualizados na Micro-CT, havendo diferença significativa apenas entre eles (p<0,001).
Title in English
Contribution of digital interproximal radiography and cone-beam computed tomography in the detection of proximal caries lesion compared to computed microtomography
Keywords in English
Cone-beam computed tomography
Dental caries
Digital radiography
X-ray microtomography
Abstract in English
Due to the importance of imaging exams in helping to detect proximal carious lesions, the objective of the present study was to analyze the accuracy of detecting these lesions through digital interproximal radiography (RID), cone-beam computed tomography (CBCT) and computed microtomography (Micro-CT) considered the gold standard, using the International Caries Detection and Assessment System (ICDAS) radiographic scoring system. One hundred and forty teeth were scanned on 3D Accuitomo 170 tomograph (J. Morita Mfg. Corp.) in the three CBCT protocols. Through image analysis, teeth classified from 0 to 4 in the ICDAS radiographic scoring system were selected for the next phases of the research. The teeth were radiographed simulating the interproximal technique with a phosphor plate (PSP) and scanned using a Skyscan 1174 microtomography (Bruker). The Micro-CT images were evaluated by two specialists in Dental Radiology to confirm the presence or absence of a carious lesion and its classification. Their responses were used as the gold standard. Four dental examiners evaluated each CBCT image and RID individually, twice, with an interval of fifteen to thirty days, classifying the lesion according to the ICDAS radiographic scoring system from 0 to 4. 26 teeth were selected, with 52 surfaces (mesial and distal) analyzed, 26 healthy surfaces (score 0), 6 lesions - score 1, 7 lesions - score 2, 7 lesions - score 3, and 6 lesions - score 4. Friedman test, Weighted Kappa test, accuracy, sensitivity, and specificity was realized. The significance of 5% was accepted. The comparison between the scores obtained using the gold standard with CBCT and DIR showed a significant difference only between Micro-CT and CBCT - Standard protocol (p<0,001). The weighted Kappa test presented values of good (0,61 0,80) or excellent (0,81 1,0) intra- and inter-examiner agreement. The values of accuracy, sensitivity and specificity, respectively, were 87%, 78,8%, and 95,2% for the CBCT Hi-Resolution (Hi-Res) protocol; 85,1%, 71,1%, and 99% for the Standard; 84,2%, 74,05%, and 94,2% for Hi-Fidelity (Hi-Fi); and 83,1%, 71,1%, 95,2% for RID. The sensitivity of each imaging method according to classification scores 1, 2, 3 and 4 were, respectively, 58,3%, 42,9%, 96,42% and 87,5% for RID; 29,2%, 64,27%, 96,4% and 95,8% for the Standard CBCT protocol; 25%, 71,4%, 96,4% and 100% for the HiFi protocol, and 33,3% , 78,5%, 100% and 95,8% for the Hi-Res protocol. It is concluded that both RID and CBCT have good diagnostic accuracy in detecting carious lesions, but considering the degrees of lesion, RID has greater sensitivity to detect incipient carious lesions and, for dentin lesions, two and three-dimensional imaging methods match up. There was a significant difference only between the Standard CBCT protocol and the Micro-CT.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
There are withheld file due to requirements (data publishing, patents or rights).
Release Date
2024-08-25
Publishing Date
2022-11-21
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.