Mémoire de Maîtrise
DOI
https://doi.org/10.11606/D.3.2003.tde-08082003-124007
Document
Auteur
Nom complet
Ronny Calixto Carbonari
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Paulo, 2003
Directeur
Jury
Silva, Emilio Carlos Nelli (Président)
Fonseca, Jun Sergio Ono
Lima, Raul Gonzalez
Titre en portugais
Projeto de atuadores piezelétricos flextensionais usando o método de otimização topológica.
Mots-clés en portugais
atuadores piezelétricos
MEMS
nanoposicionadores
otimização topológica
Resumé en portugais
Atuadores Piezelétricos Flextensionais consistem de uma estrutura flexível atuada por cerâmicas piezelétricas (ou “pilhas” de cerâmicas). A estrutura flexível conectada a piezocerâmica deve gerar deslocamentos e forças em diferentes pontos específicos do domínio, para uma direção especificada. Estes atuadores são usados em aplicações de mecânica de precisão, tal como, sistemas microeletromecânicos (MEMS), manipulador de células, interferometria laser, equipamentos de nanotecnologia, equipamentos de microcirurgias, nanoposicionadores, sonda de varredura microscópica, e etc. Porém, devido ao fato destes atuadores consistirem principalmente de um mecanismo flexível, seu projeto é complexo. A estrutura flexível comporta-se como um transformador mecânico pela amplificação para converter, direcionar e amplificar os pequenos deslocamentos gerados pela piezocerâmica (ordem de nanômetros). A estrutura flexível é projetada distribuindo-se flexibilidade e rigidez no domínio de projeto, o que pode ser obtido usando a otimização topológica. Portanto, o objetivo deste trabalho é implementar um método sistemático baseado no método de otimização topológica para projetar atuadores piezelétricos flextensionais. Essencialmente, o método de otimização topológica consiste em encontrar a distribuição ótima de material perfurando o domínio de projeto com infinitos microfuros. O material em cada ponto pode alterar de vazio a total presença de material, também assumindo material intermediário (ou compósito). A implementação do método de otimização topológica é baseado no modelo de material SIMP (Simple Isotropic Material with Penalization). O problema de otimização é posto como a maximização dos deslocamentos gerados (ou força de blocagem) em diferentes pontos e direções especificadas do domínio. Considerando o comportamento linear da piezocerâmica. Alterando a flexibilidade e a rigidez da estrutura flexível conectada a piezocerâmica obtém-se diferentes tipos de atuadores piezelétricos flextensionais, que podem ser projetados para determinadas aplicações. Para ilustrar o método, os exemplos mostrados são modelos bidimensionais (2D), uma vez que a maior parte das aplicações envolve dispositivos planos. Estes atuadores são fabricados usando corrosão química em chapas de cobre abaixo de 200 μm de espessura através do método de litografia. Técnica de corrosão química tem um baixo custo e permite-nos fabricar diversos protótipos para testes. Esta técnica pode ser facilmente utilizada no LNLS (Laboratório Nacional de Luz Síncrotron – Campinas). Análise experimental destes protótipos são procedidas para medição de deslocamentos usando uma Probe Station. Como trabalho futuro, estes protótipos serão construídos em escala de MEMS.
Titre en anglais
Design of flextensional piezoelectric actuator using the topology optimization method.
Mots-clés en anglais
flextensional piezoelectric actuators
MEMS
nanopositioners
topology optimization
Resumé en anglais
Flextensional Piezoelectric Actuators consist of a flexible structure actuated by piezoelectric ceramics (or a stack of piezoceramics). The flexible structure connected to the piezoceramic must generate displacements and forces in different specified points of the domain, according to a specific direction. These actuators are applied to precision mechanic applications such as microelectromechanical systems (MEMS), cell manipulators, laser interferometers, nanotechnology equipment, microsurgery equipment, nanopositioners, scanning probe microscopy, etc. However, due to the fact these actuators essentially consist of a compliant mechanism their design is complex. The compliant structure behaves as a mechanical transform by amplifying and changing the direction of small output displacements generated by piezoceramics (order of nanometer). The flexible structure is designed by distributing flexibility and stiffness in the design domain, which can be archieved by using topology optimization. Therefore, the objective of this work is to implement a systematic method based on topology optimization method to design flextensional piezoelectric actuators. Essentially, the topology optimization method consists of finding the optimal material distribution in a perforated design domain with infinite microvoids. The material in each point can change from void to full material, also assuming intermediate (or composite) material. The implemented topology optimization method is based on the SIMP (Simple Isotropic Material with Penalization) material model. The optimization problem is posed as maximization of output displacements (or grabbing forces) in different specified directions and points of the domain. A linear behavior of piezoceramic is considered. By changing the flexibility and stiffness of flexible structure connected to the piezoceramics different types of flextensional piezoelectric actuators can be designed for a desired application. To illustrate the method, examples presented herein are limited to two-dimensional (2D) models once in most part of applications of these actuators they are planar devices. These actuators are manufactured by using chemical corrosion on a 200 um thickness copper plate through lithography method. Chemical corrosion technique has a low cost and it allow us to manufacture several prototypes for testing. For this technique, facilities of the micromachining laboratory of National Sincroton Light Laboratory (LNLS - Campinas) are used. Experimental analysis of these prototypes are conducted by measuring displacements using a probe station. As a future work, these prototypes will be built in a MEMS scale.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
dissertacao_ronny.pdf (1.91 Mbytes)
Date de Publication
2004-04-23
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.