Master's Dissertation
DOI
https://doi.org/10.11606/D.3.1997.tde-28052024-135827
Document
Author
Full name
Andre Wulfhorst
Institute/School/College
Knowledge Area
Date of Defense
Published
São Paulo, 1997
Supervisor
Committee
Gonçalves, Edison (President)
Kachan, George Cury
Reick, Wolfgang Klaus
Title in Portuguese
Análise da taxa de corrosão do cobre eletrolítico sob fluxo de água pura
Keywords in Portuguese
Cobre
Corrosão
Abstract in Portuguese
O cobre é empregado nas mais diversas aplicações da engenharia, sendo especificado em projetos devido às suas características favoráveis à transmissão de calor e à condução de energia elétrica. Entretanto, nas condições de operação de máquinas envolvendo este material, geralmente, tem-se um fluxo de um fluido atuando sobre o mesmo, gerando corrosão e desgaste, como é o caso em trocadores de calor e estatores de hidrogeradores, por exemplo. Com a finalidade de estudar os efeitos da interação água/cobre, foi analisado o comportamento do cobre eletrolítico em água pura sob a presença de um fluxo, caracterizado como corrosão assistida por fluxo. Para tal, foi projetado e construído um aparato experimental, que gerou um fluxo controlado sobre o cobre. Verificou-se a influência da velocidade de fluxo sobre a taxa de corrosão do cobre eletrolítico, em condições conhecidas de pH, temperatura e teor de oxigênio da água pura. Gerando velocidades relativas entre o material e o meio de até 3 m/s, foi possível obter gráficos que demonstram a variação da taxa de corrosão em função do aumento da velocidade. Os resultados obtidos foram comparados com dados de outros autores, confirmando as tendências apresentadas por eles, com relação à influência da velocidade do fluxo de água sobre a taxa de corrosão do cobre. Demonstrou-se que para temperaturas mais elevadas a taxa de corrosão é maior. Obteve-se, porém, um aumento mais acentuado da taxa de corrosão em função da velocidade para temperaturas de ensaio mais baixas. De qualquer maneira, a influência da velocidade de fluxo foi constatada em todas as faixas de temperatura analisadas.
Title in English
Untitled in english
Keywords in English
Copper
Corrosion
Abstract in English
Copper is been used in the most varieted aplications of engennering. It is specified in projects, because of its favorable characteristics of heat transfer and electric energy conduction. Thus, in field operations, equipements which utilize copper, usually, have a flow over it, and that causes corrosion and wastage, like it happens in heat exchangers and hidrogenerator stators, for example. With the goal to understand the effects of the water/copper interaction, a analysis of the behavior of electrolitic copper in purê water was made, characterizing a flow assisted corrosion. That for, a special experimental aparatus was projected and constructed, which generated a controled flow over the copper. The influence of the flow velocity over the corrosion rate of electrolitic copper was verified, at known conditions of pH, temperature and dissolved oxygen in purê water. Obtaining relative velocities between the material and the solution up to 3,0 m/s, it was possible to plot curves which demonstrate the variation of the corrosion rate as a function of the increase of velocity. The obtained results were compared with data from other authors, confirming the presented tendencies related to the influence of the water flow velocity over the corrosion rate of copper. It was demonstrated, that for higher temperaturesthe corrosion rate is greater, but it was also obtained a major increase of the corrosion rate as a function of velocity at low test temperatures. But anyhow, the influence of flow velocity occures at all analyzed temperatures.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
Publishing Date
2024-05-28
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.