Mémoire de Maîtrise
DOI
https://doi.org/10.11606/D.3.2012.tde-19072013-153649
Document
Auteur
Nom complet
Mónica Baptiste Restrepo
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Paulo, 2012
Directeur
Jury
Aoki, Idalina Vieira (Président)
Melo, Hercílio Gomes de
Tanaka, Auro Atsushi
Titre en portugais
Estudo do efeito de autorreparação nos revestimentos aditivados com microcápsulas contendo óleo de linhaça.
Mots-clés en portugais
Autorreparação
EIE
Microencapsulação
Óleo de linhaça
Revestimentos inteligentes
Resumé en portugais
O objetivo deste trabalho foi a preparação de um revestimento inteligente com resina epóxi, capaz de autorreparar-se quando o sofre um defeito mecânico. A autorreparação é possibilitada pela presença de microcápsulas, dispersas na resina (revestimento de epóxi sem pigmentos) e que contêm no seu núcleo o agente de autorreparação, o óleo de linhaça. Estas cápsulas foram preparadas por uma emulsão de óleo de linhaça em água para formar micelas e sobre estas uma parede ou casca exterior de poliuréia-formaldeído. Para a avaliação da resistência à corrosão e do efeito de autorreparação do revestimento, chapas de aço carbono foram revestidas e avaliadas pela técnica de espectroscopia de impedância eletroquímica (EIE) em 0.1molL-1 1 NaCl e também foram avaliadas pelo teste acelerado de corrosão em câmara de névoa salina (SSC). Após a cura do revestimento aditivado com as microcápsulas, aplicado sobre placas de aço carbono, as medidas eletroquímicas de impedância foram realizadas em corpos de prova com um defeito mecânico provocado de forma controlada e reprodutível. Uma célula de três eletrodos foi utilizada. Estas medidas foram efetuadas após 0h, 24h e 48h da execução da incisão ou defeito mecânico. Para comparação, as mesmas medidas foram realizadas com as placas pintadas com o revestimento não-aditivado, com a mesma espessura total de 120 m. Os resultados mostraram que as cápsulas foram quebradas e se liberou o óleo de linhaça, reparando a área da incisão o defeito após pelo menos 24 horas de exposição natural ao ar ambiente. Verificou-se que para as placas revestidas sem defeito, os valores de | Z | mantiveram-se elevados. No entanto, o revestimento sem as microcápsulas, após 24 horas, mostrou uma diminuição considerável no valor de módulo de impedância, |Z|. Assim, usando a técnica de EIE foi possível avaliar quantitativamente o mecanismo de autorreparação do revestimento aditivado com microcápsulas que contêm óleo de linhaça. Os ensaios acelerados de corrosão (SSC) mostraram resultados em estreita concordância com os obtidos por EIE.
Titre en anglais
Study of the self-healing effect of coatings additivated with microcapsules containing linseed oil.
Mots-clés en anglais
EIS
Linseed oil
Microencapsulation
Self-healing
Smart coatings
SSC test
Resumé en anglais
The aim of this work was the preparation of a smart coating with epoxy resin which is able to repair itself (self-healing effect) after suffering a mechanical defect. Self-healing is possible due to the presence of microcapsules, dispersed in the resin (clear type epoxy coating) and contain in their core the self-healing agent, the linseed oil. These capsules were prepared in an emulsion of linseed oil in water to form micelles and an outer skin or wall of poly(urea-formaldehyde) was formed. For the corrosion resistance and the self-healing effect evaluation of the coating, carbon steel plates were coated and tested by electrochemical impedance spectroscopy technique (EIS) in 0.1molL-1 NaCl solution and by accelerated corrosion test in salt spray chamber (SSC). After curing of the capsules additivated epoxy based clear coating applied on carbon steel plates, electrochemical impedance measurements were performed on plates with a controlled and reproducible mechanical defect. A three-electrode electrochemical cell was used. These measurements were performed after 0h, 24h and 48h of making the incision or mechanical defect. For comparison, the same measurements were performed with the plates painted with a non- capsules additivated clear coating of the same total thickness of 120 m. The results showed that the capsules were broken and released the linseed oil, which indeed have repaired the incision area after at least 24 hours of natural air aging. It was found that for the plates coated without a defect, the values of impedance modulus, |Z|, remained high. However, the coating without the capsules after 24 hours, showed a considerable decrease in |Z|. So, using EIS it was possible to quantitatively assess the mechanism of self-healing of the additivated coating using microcapsules containing linseed oil. The SSC accelerated corrosion tests showed results in close agreement with those obtained by EIS.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Date de Publication
2013-07-30
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.