Disertación de Maestría
DOI
https://doi.org/10.11606/D.3.2008.tde-01102008-142910
Documento
Autor
Nombre completo
Robson Scaff
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Paulo, 2008
Director
Tribunal
Santos Filho, Sebastião Gomes dos (Presidente)
Angnes, Lúcio
Góngora Rubio, Mário Ricardo
Título en portugués
Caracterização elétrica de dispositivos tipo ISFET com estrutura Si/SiO2/Si3N4 para medição de pH utilizando pseudoeletrodos de Pt, Ag e Au.
Palabras clave en portugués
Circuitos integrados MOS
Eletroquímica
Microeletrônica
Resumen en portugués
Neste trabalho, foi realizado um estudo da caracterização elétrica dos ISFETs com estrutura Si/SiO2/Si3N4, utilizando pseudoeletrodos de Pt, Ag e Au como alternativas aos eletrodos convencionais para medições de pH. Primeiramente, foram empregados três métodos reportados na literatura (extrapolação linear para obtenção da tensão de limiar, segunda derivada para obtenção da tensão de limiar e corrente de sublimiar, respectivamente) com o objetivo de obter a sensibilidade dos ISFETs (mV/pH) e analisar a confiabilidade dos resultados utilizando eletrodo de referência padrão de Ag/AgCl. Posteriormente, tendo como base o eletrodo de Ag/AgCl, foram estudados os desempenhos de pseudoeletrodos de Pt, Ag e Au nas medidas de pH. Como resultado, observou-se que os pseudoeletrodos de Pt e Ag apresentaram sensibilidades compatíveis com o eletrodo de referência padrão de Ag/AgCl (~50mV/pH) para pH ácido na faixa de 1 a 3. Já o pseudoeletrodo de Au, manteve um comportamento aproximadamente linear ao longo de toda a faixa de pH estudada (1 a 10), porém, com sensibilidade inferior na faixa de 32 à 34mV/pH.
Título en inglés
Electrical characterization of ISFET devices with Si/SiO2/Si3N4 structure to measure pH using Pt, Ag, and Au pseudoelectrodes.
Palabras clave en inglés
ISFET
pH
Pseudoelectrode
Si3N4
Threshold voltage
Resumen en inglés
In this work, it is presented a study of the electrical characterization of Si/SiO2/Si3N4 estructured ISFETs using Pt, Ag and Au pseudoelectrodes as alternative references to the conventional ones for pH measurements. At first, it was used three different methods (linear extrapolation method to obtain the threshold voltage, second derivative method to obtain the threshold voltage and subthreshold-current method, respectively) having as objective to obtain the sensitivity of the ISFETs (mV/pH) and to analyze the reliability of the results using the standard Ag/AgCl reference electrode. Subsequently, using the Ag/AgCl electrode as a base for comparation, it was studied the performance of Pt, Ag and Au pseudoelectrodes for pH measurement. As a result, it was observed that the Pt and Ag electrodes presented sensitivity similar to the standard Ag/AgCl reference electrode (~50mV/pH) for pH in the range of 1 to 3. On the other hand, the Au pseudoelectrode presented an approximately linear behavior in all studied range of the pH (1 to 10), but, with lower sensitivity varying in the range of 32 to 34mV/pH.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2008-10-08
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.