Mémoire de Maîtrise
DOI
https://doi.org/10.11606/D.3.2024.tde-06052024-102033
Document
Auteur
Nom complet
Rennan de Melo Nogueira
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Paulo, 2024
Directeur
Jury
Manassero Junior, Giovanni (Président)
Encarnação, Lucas Frizera
Marte, Claudio Luiz
Titre en portugais
Análise espaço-temporal do carregamento de veículos elétricos como recurso para o planejamento de concessionárias de energia.
Mots-clés en portugais
Eletricidade
Planejamento energético
Redes de distribuição de energia elétrica
Simulação de sistemas
Veículos elétricos
Resumé en portugais
Este estudo propõe uma ferramenta de software com uma nova abordagem para a avaliação dos potenciais impactos e das possíveis restrições para recargas de veículos elétricos (EVs) na rede elétrica de áreas urbanas. A abordagem se concentra em uma análise espaço-temporal detalhada, utilizando modelos representativos de larga escala para avaliação de aspectos como o aumento das perdas de energia, a alteração do fator de potência, e a elevação da demanda e do consumo de energia. A metodologia utiliza o OpenDSS para executar estudos de casos baseados em uma rede de média tensão real, usando um banco de dados de uma subestação elétrica extraído do Geographic Information System (GIS), com um sistema de distribuição que atende cerca de 54.000 unidades consumidoras na cidade de São Paulo. As simulações consideram um caso base, sem recargas de EVs, e outros quatro cenários futuros com diferentes níveis de penetração de mercado, diferentes níveis de demanda e diferentes padrões de recarga, que incluem recargas residenciais, comerciais e em estações de recarga pelo período de vinte anos. Nas simulações realizadas, o pior cenário é previsto para os dias próximos aos feriados e projeta um aumento de 246,7% nas perdas de energia, 100,7% no pico de demanda e violação de potência de 73% dos transformadores no intervalo de tempo considerado. Além disso, o alimentador mais carregado apresentou, após dez anos, quedas de tensão abaixo de 0.9 p.u., em todos os cenários simulados, chegando a 0,72 p.u. ao final das simulações. Ao final, os dados apresentados nesse trabalho podem contribuir para o planejamento das redes de distribuição, indicando as necessidades reais e evitando superestimativas, além de confirmarem a importância da análise do modelo espaço-temporal.
Titre en anglais
Space-time analysis of electric vehicle charging as a resource for electricity utilities planning.
Mots-clés en anglais
Electric distribution networks
Electric vehicles
Electricity
Energy planning
System simulation
Resumé en anglais
This study proposes a software tool to structure a novel approach to evaluate the potential impacts of EVs on urban areas electricity grid, the constraints on the systems capacity to supply electricity for EVs recharging, and the options for managing those potential impacts and constraints. The approach focuses on a detailed spatio-temporal analysis, using large-scale representative models to evaluate aspects such as increased energy losses, power factor changes, increased demand, and energy consumption. The methodology involves the OpenDSS to run case studies based on a real medium voltage network using an electrical substation database extracted from the GIS, with a distribution system that serves around 54,000 consumers units in São Paulo. The simulations consider a base case without EVs recharges and four other future scenarios with different levels of market penetration, different levels of demand, and different recharge patterns, including residential, commercial, and station recharge over a period of twenty years. In the simulations, the worst-case scenario is expected to be the days around holidays, and it projects an increase of 246.7% in power losses, 100.7% in peak demand, and power violation in 73% of the transformers. Furthermore, the most loaded feeder showed voltage drops below 0.9 p.u. after ten years in all simulated scenarios, reaching 0.72 p.u. at the end of the simulations. In conclusion, the data presented in this work can contribute to the planning of distribution networks, indicating the real needs and avoiding overestimations, and confirming the importance of analyzing the space-time model.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Date de Publication
2024-05-20
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.