Disertación de Maestría
DOI
https://doi.org/10.11606/D.3.2004.tde-08032005-094104
Documento
Autor
Nombre completo
Paulo Futoshi Obase
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Paulo, 2004
Director
Tribunal
Piantini, Alexandre (Presidente)
Kanashiro, Arnaldo Gakiya
Ribeiro, Fernando Selles
Título en portugués
Surtos atmosféricos transferidos à rede secundária via transformador.
Palabras clave en portugués
ATP/EMTP
descargas atmosféricas
rede de distribuição de energia elétrica
Resumen en portugués
As descargas atmosféricas estão entre as principais causas de distúrbios nos sistemas elétricos, provocando sobretensões e ocasionando uma parcela significativa das interrupções não programadas. Tais distúrbios são cada vez mais percebidos pelos consumidores, ocasionando desde o mau funcionamento até a queima de aparelhos e equipamentos eletro-eletrônicos residenciais, comerciais e industriais. Antigamente eletromecânicos, tais aparelhos são atualmente, em grande parte, produzidos com componentes semicondutores, o que os torna mais sensíveis a interferências. As descargas atmosféricas também apresentam um agravante de, salvo raras exceções, não serem registradas nos bancos de dados das concessionárias, ao contrário das operações de manobra, faltas e variações de carga na rede de distribuição. Essa situação contribui para os conflitos cada vez mais freqüentes entre consumidores e empresas de energia a respeito dos pedidos de indenização por danos em aparelhos elétricos (PID). Dada a relevância do tema, muitos estudos têm sido realizados ao longo dos últimos anos, sem entretanto esclarecer todos os aspectos necessários para a minimização desses problemas. Neste trabalho são avaliadas as amplitudes e formas de onda das sobretensões transferidas à rede de baixa tensão via transformador quando da ocorrência de surtos no primário. Esses surtos podem ser oriundos de descargas diretas na rede primária ou decorrentes de descargas em suas proximidades. O estudo visa a obtenção de informações tendo em vista a melhoria do desempenho das redes de distribuição e conseqüentemente a minimização dos danos causados aos consumidores. Nas simulações, realizadas através do programa ATP (“Alternative Transients Program"), são consideradas linhas com configurações típicas, bem como modelos de comprovada validade para representação dos isoladores de média e de baixa tensão e do transformador de distribuição. O trabalho analisa a influência, nas sobretensões, de diversos parâmetros, como por exemplo amplitude e forma de onda da corrente da descarga, ponto da incidência da descarga, resistência de terra e presença de dispositivos de proteção contra surtos. Os resultados apresentados constituem-se em importantes subsídios para a definição de critérios de instalação de dispositivos de proteção contra surtos em redes de baixa tensão.
Título en inglés
Lightning surges transferred by transformer to low voltage network.
Palabras clave en inglés
ATP/EMTP
distribution lines
lightning discharge
Resumen en inglés
Lightning discharges are among the main causes of disturbances in electrical systems, causing overvoltages and leading to a significant portion of unscheduled interruptions. Such disturbances are increasingly noticed by consumers, causing from malfunction to the burnt-out of electrical-electronic devices and equipment in homes, businesses and industries. Formerly electromechanical, such devices currently are, in their majority, produced with semiconductors, what makes them more sensitive to interferences. Lightning discharges also present the aggravation of not being recorded in power suppliers’ databases, but for seldom exceptions, as opposed to switching operations, failures and charge variations in the distribution network. This situation contributes for the increasingly frequent conflicts among consumers and power companies regarding indemnity claims due to damages to electrical devices. Given the subject’s significance, many studies have been conducted along the past years, not explaining, however, all the aspects required to minimize those problems. On this work, the amplitudes and waveforms of overvoltages on medium and low voltage lines are evaluated upon the incidence of direct discharges on the primary. The voltages transferred to the low voltage side are also evaluated in case of strikes in the vicinity of the line. The study intends to obtain information in order to achieve a performance improvement of distribution networks and, as a consequence, the reduction of damages to consumers to a minimum. In the simulations conducted through ATP (“Alternative Transients Program"), lines with typical configurations are considered and models of proven validity are used to represent the low and medium voltage insulators and the distribution transformer. The work analyses the effect of several parameters on the overvoltages, such as amplitude and waveform of the stroke current, lightning strike point, grounding resistance and existence of surge protective devices. The results presented constitute an important foundation to define the installation criteria of surge protective devices on low voltage networks.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2005-08-05
 
ADVERTENCIA: El material descrito abajo se refiere a los trabajos derivados de esta tesis o disertación. El contenido de estos documentos es responsabilidad del autor de la tesis o disertación.
  • OBASE, Paulo Futoshi, et al. LIGHTNING SURGES TRANSFERRED TO THE SECONDARY OF DISTRIBUTION TRANSFORMERS DUE TO DIRECT STRIKES ON. In X International Symposium on Lightning Protection (X SIPDA), 10, Curitiba, 2009.
  • OBASE, Paulo Futoshi, PIANTINI, Alexandre, and KANASHIRO , Arnaldo Gakiya. Overvoltages caused by direct strikes on distribution lines. In Ground 2006 and 2nd LPE (Ground2006), 5, Maceio, 2006.
  • OBASE, Paulo Futoshi, PIANTINI, Alexandre, and KANASHIRO, Arnaldo Gakiya. Overvoltages on LV networks associated with direct strokes on the primary line. In 28 th International Confernece on Lightning Protection (ICLP), 28, Kanazawa, 2006.
  • OBASE, Paulo Futoshi, PIANTINI, Alexandre, and KANASHIRO, Arnaldo Gakiya. OVERVOLTAGES TRANSFERRED TO LOW VOLTAGE NETWORKS DUE TO DIRECT STROKES ON THE PRIMARY. In VIII International Symposium on Lightning Protection (VIII SIPDA) [CD-ROM], 8, São Paulo, 2005. ISSN 1676 9899.
  • PIANTINI, Alexandre, KANASHIRO, Arnaldo Gakiya, and OBASE, Paulo Futoshi. Lightning Surges Transferred to the low-voltage network. In VII International Simposium on Lightning Protection (VII SIPDA) [CD], 8, Curitiba, 2003.
  • OBASE, Paulo Futoshi, PIANTINI, Alexandre, e KANASHIRO, Arnaldo Gakiya. Efeitos de descargas atmosféricas diretas no primário das redes de distribuição São Paulo : Revista Eletricidade Moderna, 2005. Outros.