• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Master's Dissertation
DOI
https://doi.org/10.11606/D.3.2011.tde-17082011-154210
Document
Author
Full name
Odinir Klein Júnior
E-mail
Institute/School/College
Knowledge Area
Date of Defense
Published
São Paulo, 2011
Supervisor
Committee
França, Ricardo Leopoldo e Silva (President)
El Debs, Ana Lúcia Homce de Cresce
Silva, Valdir Pignatta e
Title in Portuguese
Pilares de concreto armado em situação de incêndio submetidos à flexão normal composta.
Keywords in Portuguese
Análise não linear de estruturas
Concreto armado
Incêndio
Pilares
Abstract in Portuguese
Segundo a legislação brasileira, as estruturas de concreto armado devem ser verificadas em situação de incêndio, de modo a assegurar a capacidade portante para permitir a fuga dos usuários e o combate ao fogo com segurança e minimizar a propagação do incêndio para outros compartimentos. Para estruturas de concreto armado, especial atenção deve ser dada aos pilares. A redução da capacidade portante desses elementos é significativa em situação de incêndio e seu colapso pode resultar na instabilidade global da estrutura em certos casos. O cálculo do tempo de resistência ao fogo de pilares de concreto armado, em fase de projeto, é feito normalmente usando métodos simplificados dados pelas normas técnicas. Esses métodos possuem campos de validade limitados e podem apresentar resultados excessivamente seguros (antieconômicos) e em alguns casos contra a segurança. Neste trabalho foi desenvolvida uma ferramenta computacional para o cálculo do tempo de resistência ao fogo de pilares de concreto armado em situação de incêndio, dados os campos de temperaturas simétricos na seção transversal em função do tempo de exposição ao incêndio-padrão. O cálculo do pilar foi baseado no método da estimativa da curvatura dado pelo Eurocode 2 (EN 1992-1-2:2004). A seção transversal foi discretizada em elementos (concreto e aço), na qual as deformações térmicas e as propriedades termomecânicas de cada elemento foram calculadas de acordo com sua temperatura. O método da estimativa da curvatura permite ainda considerar os efeitos da não linearidade geométrica, que geralmente se tornam importantes devido à redução da rigidez do pilar sob temperaturas elevadas. Foram modelados pilares sob flexão normal composta considerando a seção transversal aquecida de forma simétrica. Os resultados do programa foram comparados a resultados de ensaios de laboratórios internacionais, com o objetivo de validar as hipóteses de cálculo adotadas.
Title in English
Reinforced concrete columns in fire under uniaxial bending.
Keywords in English
Columns
Fire
Nonlinear structural analysis
Reinforced concrete
Abstract in English
According to Brazilian Codes, reinforced concrete structures must be verified under high temperatures, in order to assure the load bearing capacity to allow the safe evacuation of the users and the fire fighting and to reduce the fire spread to other compartments. For reinforced concrete structures, the columns must be analyzed carefully. The significant reduction in the load bearing capacity of reinforced concrete columns in fire can lead to collapse, which could result in global instability of the structure in some cases. The calculation of the fire resistance time of reinforced concrete columns, in the design phase, is usually done by means of simplified methods given by the standards. These methods are very limited and can result in excessively safe solutions (uneconomical) or unsafe solutions in some cases. A computational tool was developed for calculating the fire resistance time of reinforced concrete columns in fire, given symmetrical temperature fields in cross section as a function of exposure time to standard fire. The calculation method was developed using the method based on estimation of curvature given by Eurocode 2 (EN 1992-1-2:2004). The cross section was divided into elements (concrete and steel), in which the thermal strain and thermomechanical properties of each element were calculated according to its temperature. The mechanical behavior of the column under uniaxial bending considered the geometrically nonlinear effects of the structure, which generally become important due to reduced stiffness of the column at elevated temperatures. The results of the numerical analysis and experimental results of full-scale laboratory fire tests on concrete columns performed by international researchers were compared in order to validate the main hypothesis adopted.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.