• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Tesis Doctoral
DOI
https://doi.org/10.11606/T.3.2009.tde-29092010-163814
Documento
Autor
Nombre completo
José Luis Serra Ribeiro
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Paulo, 2009
Director
Tribunal
Selmo, Sílvia Maria de Souza (Presidente)
Aoki, Idalina Vieira
Bauer, Elton
Helene, Paulo Roberto do Lago
Panossian, Zehbour
Título en portugués
Contribuição para a avaliação da compatibilidade eletroquímica entre argamassas de reparo e concreto carbonatado.
Palabras clave en portugués
Argamassa de reparo
Compatibilidade eletroquímica
Concreto
Corrosão de armaduras
Macrocélula de corrosão
Resumen en portugués
A durabilidade das estruturas de concreto tem se tornado um assunto de interesse mundial nas últimas duas décadas. Os custos econômicos associados a reparos de estruturas de concreto são cada vez maiores, e tem crescido a incidência de insucessos nessas intervenções. No Brasil, a técnica de intervenção corretiva mais utilizada é a de reparos localizados com argamassas à base de cimento Portland, modificadas com polímeros. Uma das patologias mais comumente apresentadas, quando essa técnica é utilizada, é a volta da corrosão, porém localizada em área adjacente ao reparo, que antes estava protegida. Isto ocorre com maior freqüência em estruturas de concreto aparente ou naquelas com condições muito críticas de exposição dos elementos estruturais à umidade. Esse tipo de deterioração, conhecido na literatura como ânodo incipiente, decorre das mudanças nas características eletroquímicas do meio que envolve o aço na região do reparo, em relação ao concreto original, e pode levar a um desequilíbrio de potencial eletroquímico entre as regiões da barra de aço nesses meios, dando origem à corrosão por macrocélula. O presente trabalho consiste em uma discussão sobre os princípios eletroquímicos envolvidos na compatibilidade entre a argamassa de reparo e o concreto da estrutura, assim como sobre o mecanismo de deterioração de reparos, decorrente da incompatibilidade; desenvolve um estudo para o estabelecimento de um método de avaliação da compatibilidade eletroquímica entre as argamassas de reparo e o substrato; por fim, propõe uma escala para a interpretação dos efeitos da diferença de potencial, entre os trechos da barra de aço no reparo e no substrato, na intensidade de corrente de macrocélula entre essas áreas.
Título en inglés
Contribution to the evaluation of eletrochemical compatibility between mortar repair and carbonated concrete.
Palabras clave en inglés
Corrosion macrocell
Corrosion of reinforcement
Electrochemical compatibility
Mortar repair
Resumen en inglés
The durability of concrete structures has become a subject of worldwide interest in the last two decades. The economic costs associated with repair of concrete structures is increasing and has increased the incidence of failures in these operations. In Brazil, the technique of corrective intervention is the most widely used repair located with mortars based on Portland cement, modified with polymers. One of the diseases most commonly made when this technique is used, it is the turn of corrosion, but located in an area adjacent to the repair, before it was protected. This occurs more often in concrete structures or apparent in those conditions very critical structural elements of exposure to moisture. This type of deterioration, known in literature as incipient anode, follows the changes in the electrochemical characteristics of the environment surrounding the steel in the repair on the original concrete, and may lead to an imbalance in electrochemical potential between the regions of the bar steel in these environments, leading to corrosion by macrocélula. This work is a discussion of the principles involved in the electrochemical compatibility between the repair mortar and concrete structure as well as on the mechanism of deterioration of repairs due to incompatibility; develop a study to establish a method for assessing electrochemical compatibility between the repair mortar and the substrate, finally, proposes a scale for the interpretation of the effects of the difference in potential between the sections of steel bar in the repair and the substrate, the intensity of current of macrocélula between these areas.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2010-10-05
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.