• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Thèse de Doctorat
DOI
https://doi.org/10.11606/T.3.2011.tde-31052011-170216
Document
Auteur
Nom complet
Carlos Amado Britez
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Paulo, 2011
Directeur
Jury
Helene, Paulo Roberto do Lago (Président)
Battista, Ronaldo Carvalho
Jacintho, Ana Elisabete Paganelli Guimarães de Avila
Silva Filho, Luiz Carlos Pinto da
Silva, Valdir Pignatta e
Titre en portugais
Avaliação de pilares de concreto armado colorido de alta resistência, submetidos a elevadas temperaturas.
Mots-clés en portugais
Concreto colorido
Concreto de alta resistência
Pigmento de óxido de ferro
Pilar em situação de incêndio
Resistência ao fogo
Resumé en portugais
Apesar da quantidade de variáveis envolvidas, ainda persiste uma dúvida na comunidade acadêmica sobre o comportamento do concreto de alta resistência em situação de incêndio, considerando-o como mais ou menos suscetível à ocorrência do fenômeno de desplacamento (spalling) tipo explosivo. Em parte, essa dúvida decorre do fato de que, muitas vezes, os programas experimentais são conduzidos em amostras envolvendo corpos-de-prova padronizados, cilíndricos ou cúbicos, que não levam em consideração a influência de parâmetros relacionados com as dimensões dos elementos estruturais nem com a taxa e configuração das armaduras. Outros aspectos relevantes, como o tipo de agregado utilizado na mistura de concreto, bem como a idade e umidade interna do elemento ensaiado, dificilmente são abordados nas pesquisas e, muitas vezes, simplesmente são omitidos, o que dificulta a visão ampla e real do comportamento térmico do concreto de alta resistência. Esta pesquisa apresenta um programa experimental pioneiro realizado no Brasil em um pilar de concreto de alta resistência, armado, colorido, com idade de oito anos, fc,8anos de 140MPa, agregado graúdo basáltico, agregado miúdo quartzoso, seção transversal de 70cm x 70cm, 200cm de altura, ensaiado sem carregamento e com exposição de três faces pelo período de 180 minutos (3h), sob as temperaturas da curva-padrão de incêndio ISO 834. O pilar protótipo ensaiado é réplica dos pilares reais do edifício e-Tower, construído em 2002, na cidade de São Paulo, Brasil. Os resultados obtidos demonstraram que, neste caso, o concreto colorido de alta resistência comportou-se de forma íntegra frente ao fogo e que a utilização de pigmento à base de óxido de ferro, pode atuar também como um excelente termômetro natural, auxiliando na avaliação da condição da estrutura pósincêndio.
Titre en anglais
Evaluation of reinforced HSCC columns at high temperature.
Mots-clés en anglais
Colored concrete
Column in fire
Fire resistance
High-strength concrete
Iron oxide pigment
Resumé en anglais
In spite of the several factors that influence the behavior of concrete columns under fire conditions, there is a belief among the research community, that the high-strength concrete is more susceptible to explosive spalling than normal-strength concrete. This doubt, in part, is attributed to the small unreinforced concrete samples (specimens) used in experimental programs, to evaluate the fire resistance of structural concrete. On the other hand, relevant aspects as the coarse aggregate type used in the concrete mixture, as well as the age and content moisture (relative humidity) are not considered in the researches and sometimes simply omitted. This research presents a pioneer experimental program, carried out in Brazil on a high strength colored reinforced concrete column (HSCC) with 200cm high, eight yearsold, fc,8years of 140MPa, basalt coarse aggregate, cross section of 700mm x 700mm, tested under no load and with three faces exposed to a standard fire curve ISO 834 for a period of 180min (3h). The column prototype is a replica of the actual columns of the e-Tower Building, constructed in 2002 in São Paulo city, Brazil. The results demonstrated concrete column integrity under experimental fire and that the iron oxide pigments can work as an excellent natural thermometer, contributing in the evaluation of the structure post-fire.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Date de Publication
2011-06-28
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.