• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Disertación de Maestría
DOI
https://doi.org/10.11606/D.3.2010.tde-18082010-165358
Documento
Autor
Nombre completo
Barbara Elisabeth Waelkens
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Paulo, 2010
Director
Tribunal
Ferreira Filho, Sidney Seckler (Presidente)
Boscov, Maria Eugênia Gimenez
Mendes, Carlos Gomes da Nave
Título en portugués
Tratamento de efluentes industriais mediante a aplicação de argila organifílica e carvão ativado granular.
Palabras clave en portugués
Adsorção (tratamento de águas)
Tratamento de águas residuárias
Resumen en portugués
A presença do óleo pode trazer graves problemas ambientais quando lançado em corpos dágua. A remoção de óleos e graxas de efluentes industriais, principalmente quando na forma emulsificada ainda é um desafio para o tratamento de efluentes industriais. Argilas quimicamente modificadas com sais quaternários de amônio podem ser uma alternativa para o tratamento de efluentes oleosos por apresentarem características organofílicas, podendo desta forma ser utilizadas como material adsorptivo. O presente trabalho estuda a aplicabilidade de uma argila organofílica granular, seja de forma simples ou em combinação com carvão ativado granular, como meio filtrante para a remoção de óleos e graxas de dois efluentes industriais reais oriundos de uma indústria de laminação a frio e uma indústria automobilística. Ambos os efluentes apresentam concentrações baixas de óleos e graxas, variando entre 5 e 30 mg/l de óleos e graxas, entretanto, estes valores não estão sempre em concordância com a legislação vigente. A análise gravimétrica de óleos e graxas não forneceu dados confiáveis, entretanto, foi possível observar uma redução da concentração de carbono orgânico total (COT) após o tratamento com a argila organofílica granular. A redução da concentração de COT foi ainda maior após o tratamento do efluente com a composição Argila Organofílica Granular seguida de Carvão Ativado Granular. Tal composição é a mais recomendada, pois garante bons resultados, além de aumentar a vida útil do carvão ativado.
Título en inglés
Industrial wastewater treatment through the use of granular organoclay and granular activated carbon.
Palabras clave en inglés
Adsorption (water treatment)
Wastewater treatment
Resumen en inglés
The presence of oil in rivers, lakes and oceans can cause serious environmental hazards. The removal of oil and grease from industrial effluents, especially in its emulsified form, is still a challenge for the industrial wastewater treatment sector. Clays chemically modified with quarternary ammonium salts can be an alternative for the treatment of oily wastewater. Given its organophilic characteristics these organoclays can be used as adsorptive media. The present study evaluates the applicability of a granular organoclay, be it in its simple form, or combined with activated granular charcoal, as a filtration medium for the oil and grease removal of two industrial effluents. Both effluents, one of a cold lamination industry and one of an automotive industry, have low oil and grease concentrations, between 5 and 30 mg/L, however these concentrations do not always comply with local directives. The data obtained by the gravimetric Oil and Grease analysis were not reliable, however it was possible to observe a reduction in the Total Organic Carbon (TOC) concentration of the effluent treated with the granular organoclay. It was also observed that the TOC concentration of the effluent was even larger when the effluent was treated with the composition, granular organoclay (GOC) followed by granular active charcoal (GAC). Thus, the composition GOC followed by GAC is the most recomended, for it garantees reliable results and enhances the GAC lifespan.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2010-09-23
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.