• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Mémoire de Maîtrise
DOI
https://doi.org/10.11606/D.39.2011.tde-20012011-133804
Document
Auteur
Nom complet
Eduardo Marcel Fernandes Nascimento
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Paulo, 2011
Directeur
Jury
Bertuzzi, Rômulo Cássio de Moraes (Président)
Kiss, Maria Augusta Peduti Dal Molin
Pires, Flávio de Oliveira
Titre en portugais
Determinação das zonas de transição metabólica durante a corrida mediante os limiares de variabilidade da frequência cardíaca
Mots-clés en portugais
Consumo de oxigênio
Lactato sanguineo
Limiar Aeróbio
Limiar Anaeróbio
Teste progressivo até a exaustão
Variabilidade da frequência cardíaca
Resumé en portugais
O propósito do presente estudo foi obter evidências de validade e reprodutibilidade dos limiares de variabilidade da frequência cardíaca (VFC) durante a corrida. Dezenove sujeitos homens, saudáveis e praticantes de corrida (30,4 ± 4,1 anos; 175,9 ± 6,4 cm; 74,3 ± 8,5 kg) foram submetidos a um teste progressivo máximo em esteira rolante com velocidade inicial 5 km.h-1 e incrementos de 1 km.h-1 a cada 3 minutos (1% de inclinação constante) até exaustão voluntária. Todos os indivíduos realizaram o reteste em um intervalo de tempo entre 48 horas e uma semana. Foram realizadas as medidas das trocas gasosas, do lactato sanguíneo e da VFC (plotagem de Poincaré). Os limiares aeróbio (LAe) e anaeróbio (LAn) foram determinados pelos limares de lactato, ventilatórios e da VFC. Para a comparação entre os métodos foi uitlizada ANOVA para medidas repetidas, acompanhada de teste de post hoc de Bonferroni. A reprodutibilidade das variáveis analisadas foram verificadas pela plotagem de Bland-Altman e pelo coeficiente de correlação intraclasse (CCI). Os resultados do presente estudo demonstraram que a velocidade correspondente ao segundo e terceiro modelos utilizados para se determinar o LA pela VFC não eram significativamente diferentes (p > 0,05) do primeiro limiar de lactato e ventilatório. Em relação ao LAn, não foram observadas diferenças significativas nas velocidades correspondentes ao LAn detectado pelos diferentes métodos (p > 0,05). Os valores do CCI estavam entre 0,69 a 0,80 (p < 0,001). Conclui-se que o LAe e o LAn podem ser identificados pela análise da VFC, desde que se utilize os procedimentos empregados na presente investigação
Titre en anglais
Determination of transition metabolic zones during running using hert rate variability thresholds
Mots-clés en anglais
aerobic threshold
anaerobic threshold
blood lactate
heart rate variability
incremental test to exhaustion
oxygen uptake
Resumé en anglais
The aim of the present study was to obtain evidences of validity and reliability of the thresholds of heart rate variability (HRV). Nineteen male subjects, healthy and runners (30,4 ± 4,1 years; 175,9 ± 6,4 cm; 74,3 ± 8,5 kg) performed a progressive maximal test on a treadmill with initial velocity 5 km.h-1 e increases of 1 km.h-1 every 3 minutes (1% slope) until voluntary exhaustion. All subjects performed the retest at an interval of time between 48 hours and one week. It was measured gas exchange, blood lactate and heart rate variability (Poincaré plot). The aerobic threshold (AT) and anaerobic (AnT) were determined by lactate, ventilatory and heart rate variability. ANOVA for repeated measures and post-hoc test of Bonferroni was used to compare the methods. To analyze the reproducibility of the variables were used the Bland- Altman plots and intraclass correlation coefficient (ICC). The results of this study show that the velocity at the second and third models employed to determine the AT by HRV were not significantly different (p > 0.05) of the first lactate threshold and ventilatory. Similarly, there were no significant differences in the velocities corresponding to AnT detected by different methods (p> 0.05). The ICC values were between 0.69 to 0.80 (p < 0.001). We conclude that the AT and the AnT can be estimated by HRV analysis, since it utilizes the procedures employed in this study
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
CAPA_Projeto.pdf (4.10 Kbytes)
FOLHA_DE_ROSTO.pdf (4.38 Kbytes)
PROJETO_Final.pdf (832.56 Kbytes)
SUMARIO_Projeto.pdf (62.34 Kbytes)
Date de Publication
2011-05-19
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.