• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Mémoire de Maîtrise
DOI
https://doi.org/10.11606/D.42.2012.tde-09112012-115558
Document
Auteur
Nom complet
Luana de Cássia Umeda
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Paulo, 2012
Directeur
Jury
Mehnert, Dolores Ursula (Président)
Carmona, Rita de Cássia Compagnoli
Mucci, José Luiz Negrão
Titre en portugais
Métodos clássicos e moleculares para avaliação da qualidade virológica de lodo de esgoto e de água de reúso: determinação da eficiência e limites de detecção.
Mots-clés en portugais
Adenovírus
Lodo de esgoto
Reúso da água
Rotavírus
Saneamento
Resumé en portugais
Os vírus entéricos humanos são encontrados no esgoto e em subprodutos dos processos de tratamento. Recentemente vem sendo recomendados como indicadores de qualidade microbiológica em normas da legislação brasileira e também nas de outros países, mas ainda com parâmetros a definir. O objetivo do estudo é a avaliação e a comparação entre métodos clássicos e moleculares aplicados à detecção de vírus entéricos em amostras de água de reúso e de lodo, visando subsidiar a legislação brasileira. Ensaios de semeadura experimental de protótipos de rotavírus e de adenovírus foram realizados nas matrizes ambientais e os vírus detectados por métodos clássicos (cultivo celular e reação de imunoperoxidase) e moleculares (PCR/nested-PCR, RT-PCR e ICC-PCR), determinando-se os limites de detecção de cada método para cada matriz. A pesquisa de rotavírus e adenovírus presentes naturalmente em 25 amostras de água de reúso e em 25 de lodo possibilitou a comparação dos métodos propostos. O ICC-PCR mostrou ser o método mais factível a ser aplicado na área de saneamento.
Titre en anglais
Standard and molecular methods for surveillance of human enteric viruses in sludge and reclaimed water: efficiency and detections limits.
Mots-clés en anglais
Adenovirus
Reclaimed water
Rotavirus
Sanitation
Sludge
Resumé en anglais
Human enteric viruses are common contaminants of raw sewage and subproducts of sewage treatment processes. In recent years, those viruses were recommend as new microbiological indicators in different matrices in Brazilian legislation and others countries, although some questions should be elucidated. At present, the aim was to evaluate and compare the efficiencies of standard and molecular virological methods for detection of human enteric viruses in sludge and reclaimed water samples. Rotavirus and adenovirus were experimentally spiked in the proposed matrices and virus recovery and detection limits established for each method and matrice. Viruses naturally presented in 25 samples of sludge and 25 samples of reclaimed water were assayed by all methods and results evaluated and compared for statistical significance. From all methods evaluated, ICC-PCR showed to be the most suitable for virus surveillance in sludge and reclaimed water.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Date de Publication
2013-02-08
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.